LW-IGW7404MΪÁ½´®¿Ú£¨RS485£©ModbusÖÇÄÜÍø¹Ø£¬×¨ÃÅÕë¶ÔPLC¡¢HMI »òÕß×é̬Èí¼þµÄ²É¼¯¡£´«Í³µÄModbusÍø¹ØÖ»ÊÇModbus TCPºÍModbus RTUÐÒé×ö¸öת»»£¬Íø¹Ø±¾Éí²¢²»Ö÷¶¯²É¼¯Êý¾Ý£¬¶øIGW7404M ModbusÖÇÄÜÍø¹ØÊÇ¿ÉÒÔÖ÷¶¯²É¼¯´ÓÕ¾Êý¾Ý²¢»º´æµ½Íø¹ØÄÚ²¿£¬´Ó¶øÉÏλ»ú¿ÉÒÔͨ¹ýTCP»òÕßRS485×ÜÏßÖ±½Ó´ÓModbusÖÇÄÜÍø¹ØÈ¡Êý¾Ý£¬ÕâÑù¾Í¼õÉÙÁËÉÏλ»úÖ÷Õ¾Óë´ÓÕ¾µÄ½»»¥´ÎÊý£¬¼«´óµØÌá¸ßÁ˲ɼ¯ËÙ¶È£¬ÊµÊ±ÐÔ£¬¿É¿¿ÐÔÒÔ¼°Îȶ¨ÐÔ£»¶ÔÓÚ¶àRS485Ö÷Õ¾ÏëÒª·ÃÎÊÏàͬµÄ´ÓÕ¾Êý¾Ý£¬´«Í³µÄModbusÍø¹ØÊÇÎÞ·¨½â¾öµÄ£¬¶øÓÉÓÚModbusÖÇÄÜÍø¹ØÊÇ×Ô¶¯²É¼¯²¢´æ´¢Êý¾Ý£¬Òò´ËÍêȫ֧³Ö¶àÖ÷վͬʱͨ¹ýRS485×ÜÏß¶ÁÈ¡Êý¾Ý£»ÁíÍ⣬Õë¶ÔһЩûÓÐÒÔÌ«Íø¿ÚµÄPLC»òÕßHMI£¬Ò²¿ÉÒÔͨ¹ýModbusÖÇÄÜÍø¹ØµÄRS485¶Ë¿Ú£¬²É¼¯µ½Modbus TCP´ÓÕ¾µÄÊý¾Ý¡£
Õë¶Ô¹¤ÒµÓ¦Óã¬RJ-45ͨѶ½Ó¿Ú²ÉÓùâµç¸ôÀëÉè¼Æ£¬±ÜÃ⹤ҵÏÖ³¡ÐźŶÔͨѶ½Ó¿ÚµÄÓ°Ï죬¾ßÓÐÁ¼ºÃµÄ¼æÈÝÐÔ¼°Îȶ¨ÐÔ£»±ê×¼Modbus TCPͨѶÐÒé¼°³£Óù¦ÄÜÂ룬ʹµÃÓû§¿ÉÒÔ¸ü¼ÓÇáËÉʵÏÖÓëSCADAÈí¼þ¡¢HMIÉ豸¼°Ö§³ÖModbus TCPÐÒéµÄPLCµÈÉ豸ºÍϵͳµÄÕûºÏÓ¦Óã»ÌṩÐÒéºÍʾÀý´úÂ룬ʹÄúµÄ¶þ´Î¿ª·¢¸ü¼ÓÁé»î¡¢¼ò±ã¡¢¸ßЧ¡£
±¾²úÆ·¹ã·ºÓ¦ÓÃÓÚ£ºÒ½ÁÆ¡¢¹¤¿ó²úÆ·¿ª·¢ £»¹¤¿Ø½ÌѧӦÓÃÔ¶³ÌͨѶ £»»ú·¿¶¯Á¦»·¾³¼à¿Ø£»Òƶ¯Êý¾Ý²É¼¯Õ¾ £»ÖÇÄÜÂ¥Óî¿ØÖÆÊý¾Ý¡¢°²·À¹¤³ÌµÈÓ¦ÓÃϵͳ £»»úе¡¢Ïû·À¡¢Ê¯»¯¡¢½¨Öþ¡¢µçÁ¦¡¢½»Í¨µÈ¸÷ÐÐÒµTCP/IPÍøÂ繤ҵ×Ô¶¯»¯¿ØÖÆÏµÍ³µÈÁìÓò¡£
ModbusÖÇÄÜÍø¹Ø4¿ÚRS485 Modbus RTU?Modbus TCP ÐÔÄÜÌØµã¡¿
1¡¢¼æÈÝÐÔÇ¿£¬Ö§³Ö½ÓÈëËùÓг§¼Ò±ê×¼µÄMODBUSÐÒéµÄ²É¼¯Ä£¿é
2¡¢¾ßÓÐModbus TCP/IP¡¢Modbus Rtu¡¢Serial PortµÈÈýÖÖ²Ù×÷ģʽ
3¡¢Í¨¹ýÍøÒ³ä¯ÀÀÆ÷¡¢ÉèÖÃÈí¼þ½øÐвÎÊýÐÞ¸ÄÉèÖÃ
4¡¢¶ÔÓÚÐèÒª¿ª·¢Èí¼þµÄÓû§£¬ÎÒÃÇÃâ·ÑÌṩ¶þ´Î¿ª·¢°üSDK
5¡¢Ë«Ó²¼þ¿´ÃŹ·£¬¾ø²»ËÀ»ú
6¡¢²ÉÓÃ32λARMǶÈëʽCPU£¬¸ßÐÔÄܵ͹¦ºÄ
7¡¢²ÉÓÃModbus TCPͨÐÅÐÒ飬֧³Ö¿Í»§¶ËºÍ·þÎñÆ÷ģʽ
8¡¢·á¸»µÄµÄָʾµÆ£¬·½±ãµ÷ÊÔ
9¡¢RJ-45ͨÐŽӿÚÌṩ·ÀÀ×±£»¤
10¡¢µçÔ´¾ßÓйýÁ÷¡¢¹ýѹ¡¢·À·´½Ó¼°·ÀÀ×±£»¤
11¡¢¿íµçÔ´µçѹÉè¼Æ
12¡¢¹¤Òµ¼¶Î¶ȷ¶Î§£¬Ó¦¶ÔÑÏ¿ÁÏÖ³¡»·¾³
13¡¢±ê×¼µ¼¹ì°²×°»òÂݶ¤¹Ì¶¨
¡¾¼¼Êõ²ÎÊý¡¿
¡¾²úÆ·ÓÅÊÆ¡¿
¸ü¸ßµÄ²É¼¯ËÙ¶È¡£
Ôڲɼ¯¶à¸öModbus´ÓÕ¾Êý¾Ýʱ±È´«Í³ModbusÍø¹Ø²É¼¯ËÙ¶È¿ìºÜ¶à£¬´«Í³µÄModbusÍø¹ØÖ»ÊÇModbus RTUÓëModbus TCPµÄÐÒéת»»£¬±¾Éí²¢²»´¦ÀíÊý¾Ý£¬¶øIGW7204MÖÇÄÜÍø¹ØÊÇ×Ô¶¯²É¼¯Êý¾Ý²¢»º´æµ½±¾µØ¡£Òò´Ë£¬Èç¹ûÖ÷Õ¾Òª²É¼¯100̨´ÓÕ¾Êý¾Ý£¬Ô±¾Òª100´Î¶ÁÃüÁ¶øÍ¨¹ýIGW7204M ModbusÖÇÄÜÍø¹Ø£¬×îÓŵÄÇé¿öÊÇÖ»ÐèÒªÒ»´Î¶ÁÃüÁî¾Í¿ÉÒÔ¡£
¸ü¸ßµÄ¿É¿¿ÐÔ¡£
½«¶à¸ö¶ÁÃüÁîÖеÄÊý¾Ý¼¯Öе½¼¸¸öÃüÁîÀ´Íê³É£¬¼õÉÙÊý¾Ý²É¼¯¹ý³ÌÖÐÀ´»Ø½»»¥µÄ´ÎÊý£¬Ò²¾Í¼õÉÙÁ˳ö´í¸ÅÂÊ¡£
Ö§³Ö¶àRS485Ö÷Õ¾¡£ÒòΪ´øÓлº´æ£¬¿ÉÒÔÉèÖöà¸ö485Ö÷վͬʱ²É¼¯Ò»Â·485´ÓÕ¾Êý¾Ý£¬µ±×ö485¹²ÏíÆ÷À´Ê¹Ó㬸ÃÓ¦ÓöàÓÃÓÚµç±í£¬Ë®±í£¬È¼Æø±íµÈÊý¾Ý³ËÍϵͳ£¬½â¾ö485×ÜÏß³åÍ»ÎÊÌâ¡£
´«Í³ModbusÍø¹ØÊDz»ÄÜÖ§³ÖRS485×ÜÏßÉ϶à¸öÖ÷Õ¾µÄ£¬ÔÒòÊǶàÖ÷Õ¾»á²úÉúÊý¾Ý³åÍ»¡£¶øÊ¹ÓÃIGW7204M ModbusÖÇÄÜÍø¹Ø¾Í²»´æÔÚÕâ¸öÎÊÌâ¡£¶àÖ÷Õ¾ÊÇÖ±½ÓÓëÖÇÄÜÍø¹ØÍ¨Ñ¶£¬¶ÁдÖÇÄÜÍø¹Ø»º³åÖеÄÊý¾Ý¡£
Ö§³Ö¶àModbus TCPÖ÷Õ¾¡£
´«Í³Modbus TCPÍø¹ØÔÚ¶à¸öÖ÷վͬʱ·ÃÎÊ´Óվʱ£¬²ÉÓÃÅŶӵĻúÖÆ£¬ÕâÊÜÖÆÓÚRS485×ÜÏßͬʱֻÄÜÓÐÒ»¸öÖ÷Õ¾¡£Òò´Ëͬʱ·ÃÎʵÄÖ÷Õ¾Ô½¶à£¬»Ø¸´»áÔ½Âý¡£¶øIGW7204M ModbusÖÇÄÜÍø¹ØÊǰÑÊý¾Ý»º³åÔÚÉ豸ÄÚ²¿£¬ÊµÊ±¶ÁÈ¡£¬Ã»ÓÐÑÓʱ¡£
±à³Ì¸ü¼òµ¥¡£
ͨ¹ýPLC»ò×é̬Èí¼þ²É¼¯ÊýÊ®¸öÉ豸µÄÊý¾Ý£¬±à³Ì¹ý³Ì±È½Ï·±Ëö¡£¶øÍ¨¹ýIGW7204M ModbusÖÇÄÜÍø¹Ø£¬±à³Ì¹ý³Ì±äµÃ¼òµ¥ºÜ¶à£¬Ö»ÐèÒª¼¯Öд¦ÀíËù²É¼¯µÄÊý¾Ý¡£
ÍêÉÆµÄ´íÎó¸ú×Ù»úÖÆ¡£
´«Í³ModbusÍø¹ØÖ»Êý¾Ýת»»£¬²»×öÊý¾Ý½»»¥µÄÂß¼Åжϣ¬ËùÒÔ²»»á¼Ç¼´íÎóÐÅÏ¢£¬ÕâЩ´íÎó·ÖÎö¶¼ÐèÒªÔÚÉÏλ»ú´¦Àí¡£Ôڲɼ¯ºÜ¶à´Óվʱ£¬ÈôÓÐһ̨´ÓÕ¾³öÎÊÌ⣬ºÜÄÑÔںܶÌʱ¼äÄÚÅŲé³öÀ´¡£¶øIGW7204M ModbusÖÇÄÜÍø¹ØÄÚ²¿¼¯³ÉÁËÏêϸµÄÈÕÖ¾¹¦ÄÜ£¬¿ÉÒÔ¿ìËÙÕÒµ½³öÎÊÌâµÄ´ÓÕ¾£¬Ç°ÆÚµ÷ÊԷdz£·½±ãºÍѸËÙ¡£Í¬Ê±£¬ÉÏλ»úÒ²¿ÉÒÔ¶ÁÈ¡ËùÓдÓÕ¾µÄ¹¤×÷״̬£¬¼°Ê±·¢ÏÖÎÊÌⲢ֪ͨ¹¤×÷ÈËÔ±¡£
½µµÍ¹¤³Ì³É±¾¡£
ÔÀ´ÐèÒª¶ą̀PLC²É¼¯Êý¾Ý£¬ÏÖÔÚһ̨Êý¾Ý²É¼¯Æ÷ÅäºÏһ̨PLC¾Í¿ÉÒÔÍê³É²É¼¯¡£
Íø¹Ø·ÖΪÆÕͨÐͶàÖ÷»úºÍ´¢´æÐÍ¡£ÆÕͨÐÍËäÈ»¿ÉÒÔÖ§³Ö¶à¸öÖ÷»úͬʱ·ÃÎÊ£¬µ«ÊÇÿ´ÎModbus TCPµÄ²éѯ¶¼Òª×ª»¯Îª´®¿ÚÊý¾Ý£¬µÈ´®¿Ú·µ»Øºó²ÅÄܸøÖ÷»ú·µ»Ø²éѯ½á¹û£¬ËùÒÔ·´Ó¦Ê±¼ä½ÏÂý£¬Ò»°ãÔÚ30¡«50ms¡£¶ø´¢´æÐÍModbusÍø¹Ø¿ÉÒÔ×Ô¶¯¼Ç¼ModbusÖ÷»úËùÐèÒªµÄÊý¾Ý£¬Ã¿Ê±Ã¿¿ÌÖ÷¶¯´Ó´®¿Ú²éѯRTUÉ豸£¬¸üÐÂ×Ô¼º»º´æµÄÊý¾Ý¡£µ±Ö÷»úÐèÒªÊý¾ÝÊÇÖ»´Ó»º´æÖзµ»Ø
²éѯʱ¼äԼΪ1ms£¬´ó´ó¼Ó¿ìÁ˶àÖ÷»úµÄ´¦ÀíÄÜÁ¦¡£