²úÆ·Ãû³Æ£ºXFU400ϵÁÐÁ¦´«¸ÐÆ÷
²úÆ·ÌØÐÔ£º•±ê×¼¸Ë¶ËÖá³Ð •µÍÆ«ÒÆ •°²×°¼òµ¥ •¿ìËÙÏìÓ¦ •¾²Ì¬ºÍ¶¯Ì¬²âÁ¿
ѹÁ¦ÀàÐÍ£ºÁ¿³Ì£¨Lbf£©£º 100 ~1K
²úÆ·Ó¦Ó㺽ӺÏÁ¦²âÁ¿£¬»úе¹¤¾ß£¬Æû³µÏµÍ³²âÊÔ£¬»úÆ÷È˺͵ç×Ó²Ù×Ý×°ÖÃ
²úÆ·½éÉÜ£º XFU400ϵÁÐÁ¦´«¸ÐÆ÷ÓжàÖÖÁ¿³ÌºÍ°²×°ÂÝÎÆ¿ÉÑ¡£¬°²×°¼òµ¥£¬³ß´çС£¬ÓÃÓÚ¿Õ¼äÊÜÏÞµÄÓ¦Ó᣸ô«¸ÐÆ÷²ÉÓøßÎȶ¨ÐÔ΢»úе¹èÓ¦±äƬ×é³ÉµÄȫζȲ¹³¥»Ý˹ͨµçÇÅ¡£XFU400Ö÷ÒªÓ¦ÓÃÓÚÐèÒª¹Ø½ÚÖá³ÐµÄ³¡ºÏ£¬Á¿³Ì¸ß´ï5kN£¨1kLbf£©¡£ ÎÒÃǿɸù¾Ý¿Í»§ÐèÒªÌṩ³ÉÌ×ϵͳ¡£ÅäÌ×Ôª¼þ£¨´«¸ÐÆ÷£¬µçÔ´£¬·Å´óÆ÷ºÍÊýÏÔϵͳ£©ÅäÖÃͳһ£¬¾¹ýУÕý£¬¿É¹©¿Í»§Á¢¼´Ê¹Óá£
²úÆ·²ÎÊý£º
Á¿³Ì£¨Lbf£©£º 100 ~1K
Êä³ö£º10mV/V
Operating Temperature Range (OTR)£º -40 to 120 ° C [-40 to 248 ° F]
Compensated Temperature Range (CTR) £º0 to 60 º C [32 to 140 ° F]
Zero Shift in CTR £º<2% F.S. / 50 ° C [/100 ° F]
Sensitivity Shift in CTR £º<2% of reading / 50º C [/100° F]
Range (F.S.) £º0-500N to 0-5kN [0-100lbf to 0-1klbf]
Over-Range
Without Damage £º1.5 x F.S.
Without Destruction£º 2 x F.S.
Accuracy
Linearity £º≤±0.3% F.S
Hysteresis £º≤±0.2% F.S