À×´ïҺλ¼ÆFMR53 ÊÊÓÃÓÚ¼òµ¥¹¤¿öϵÄҺλ²âÁ¿
Êä³ö
µ÷ÊÔ Micropilot ʱ£¬ÐèÒªÊäÈë¿Õ±ê¾àÀë“E” (Áãµã)¡¢Âú±ê¾àÀë“F ” (ÂúÁ¿³Ì)ºÍÓ¦ÓòÎÊý£¬ÒDZí×Ô¶¯
ÊÊÓ¦¹ý³ÌÌõ¼þ¡£µçÁ÷Êä³öÐÍÒDZíµÄÁãµã(E)ºÍÂúÁ¿³Ì(F)µÄ¹¤³§ÉèÖÃÖµ·Ö±ðΪ 4 mA ºÍ 20 mA£»Êý×Ö
Á¿Êä³öÐÍÒDZíºÍÏÔʾµ¥ÔªµÄÁãµã(E)ºÍÂúÁ¿³Ì(F)µÄ¹¤³§ÉèÖÃÖµ·Ö±ðΪ 0 %ºÍ 100 %¡£Êý×ÖʽÊä³öÐÍ
ÒDZíºÍÏÔʾµ¥ÔªµÄÁãµã“E”ºÍÂúÁ¿³Ì“F”·Ö±ðΪ 0 %ºÍ 100 %¡£
¿ÉÒÔÊÖ¶¯»ò°ë×Ô¶¯ÊäÈëÏßÐÔ»¯±í(×î¶à°üº¬ 32 ²ÎÊý¶Ô)£¬Í¨¹ýÏÖ³¡²Ù×÷»òÔ¶³Ì²Ù×÷¿ÉÒÔ¼¤»îÒDZíµÄ
ÏßÐÔ»¯¹¦ÄÜ¡£ÏßÐÔ»¯¹¦ÄÜ¿ÉÒÔÌṩÆäËû¹¤³Ìµ¥Î»µÄ²âÁ¿Öµ£¬²¢¿ÉÒÔÌṩÇò¹Þ¡¢ÎԹ޺ʹø×¶ÐγöÁÏ
¿Ú¹ÞÌåµÄÏßÐÔÊä³öÐźš£
²úÆ·ÉúÃüÖÜÆÚ
Éè¼Æ
• ͨÓòâÁ¿ÔÀí
• ²âÁ¿²»ÊܽéÖÊÌØÐÔµÄÓ°Ïì
• Ó²¼þºÍÈí¼þ¿ª·¢·ûºÏ SIL IEC 61508 ±ê×¼
|
²âÁ¿ÔÀí
|
À×´ïÎïλÒÇ
|
|
ÌØµã/Ó¦ÓÃ
|
For common non-contact continuous level measurement in liquids,
especially suited for small process connections and for chemically aggressive media;
Rod antenna with PTFE coating
|
|
ÌØµã
|
SIL 2 according to IEC 61508,
Safety and reliability with Multi-Echo Tracking,
HistoROM
|
|
µçÔ´/ͨÐÅ
|
2-wire (HART / PROFIBUS PA/ FOUNDATION Fieldbus)
4-wire (HART)
|
|
ƵÂÊ
|
C-band (~6 GHz)
|
|
²âÁ¿¾«¶È
|
+/- 6 mm (0.24 in)
|
|
»·¾³Î¶È
|
-40...+80 °C
(-40...+176 °F)
|
|
¹ý³ÌζÈ
|
-40...+150 °C
(-40...+302 °F)
|
|
¹ý³ÌѹÁ¦£¨¾øÑ¹£©/×î´ó¹ýѹÏÞ¶¨Öµ
|
Vacuum...40 bar
(Vacuum...580 psi)
|
|
Ö÷Òª½ÓÒº²¿¼þ
|
PTFE, PVDF
|
|
¹ý³ÌÁ¬½Ó
|
Thread:
MNPT 1 1/2, R 1 1/2
Flange:
DN50...DN150,
ASME 2"...6",
JIS 10K
|
|
×î´ó²âÁ¿¾àÀë
|
20 m (65 ft)
|
|

|
|
Îï룬Á÷Á¿£¬Ñ¹Á¦£¬Ë®·ÖÎö²âÁ¿²â¿Ø£ºµÂ¹úE+H£¬µÂ¹úVEGA£¬ÃÀ¹ú¹þÏ££¬ºáºÓÎнÖÁ÷Á¿¼Æ£¬ºáºÓµç´ÅÁ÷Á¿¼Æ£¬ÎнÖÁ÷Á¿¼ÆºáºÓ¡£ÃÀ¹úEMAÁ÷Á¿´«¸ÐÆ÷¡£Î¢ÐŹ«ÖÚÆ½Ì¨£ºÎ÷°²ºêÂÔóÒ×ÓÐÏÞ¹«Ë¾¡£E+H´úÀíÉÌ£¬Ô×°½ø¿ÚVEGA,µÂ¹ú½ø¿ÚE+H,ÏÖ»õÃÀ¹úHACH,ºáºÓ´¨ÒÇ¡£CM442£¬CPS11D,Һλ¼ÆFMU40¡£À×´ïÁÏλ¼ÆFMR51£¬FMR57£¬ÒºÎ»¼ÆFMP51£¬FMP56ÏÖ»õ¡£SON61£¬FLEX81(61),PSSR68£¬PSWL61£¬PULS69Ô×°½ø¿Ú¡£