²úÆ·Ãû³Æ£º
|
MARS1301 ÎÞÏß´®¿Ú·þÎñÆ÷
|
ÐÍ ºÅ£º
|
MARS1301
|
¼Û ¸ñ£º
|
0.00
|
Æ· ÅÆ£º
|
Aineton
|
|
|
|
|
|
¡¡¡¡MiniMars1301Ö§³ÖRS-232ͨѶ½Ó¿Ú£¬Äܹ»Âú×ãËùÓй¤Òµ´®¿ÚÉ豸µÄÓ¦Óü°´«Ê䷽ʽ¡£Ê¹ÓøßÐÔÄÜÍøÂç´¦ÀíÆ÷£¬Ö÷Ƶ¸ß´ï100M£¬ÄÚ´æ2M,ÍêȫʤÈθ÷ÖÖÍøÂç»·¾³¡£
¡¡¡¡MiniMars1301ÊÇÒ»¸ö¿ÉÒÔÈù¤ÒµÓÃRS-232´®¿ÚÉ豸Á¢¼´¾ß±¸ÎÞÏßÁªÍøÄÜÁ¦µÄÉ豸ÁªÍø·þÎñÆ÷¡£ÈçµçÁ¦¼à¿Ø¡¢»ú·¿¼à¿Ø,PLC¡¢CNC¡¢ÖÇÄܵç±í¡¢ÃºÆø±í¡¢ÉúÎïʶ±ð×°ÖᢶÁ¿¨»ú¡µÈ,ÊÇ Á¬½á¹¤ÒµÓô®¿ÚÉ豸¼°TCP/IPÒÔÌ«ÍøÂçµÄ×î¼ÑͨѶ½â¾ö·½°¸¡£ | |
|
|
|
|
|
|
¡¡¡¡ ·á¸»µÄ¹¤×÷ģʽ,¿ÉÒÔÂú×ã¿Í»§µÄ²»Í¬ÐèÒª | |
|
VCOMģʽ |
VCOM¿ÉÒÔÈÃÒ»¸ö´®¿Ú¶ÔÓ¦Ò»¸öM1000´®¿Ú·þÎñÆ÷¡£ÌṩWindows ±ê×¼´®¿ÚÇý¶¯³ÌÐò£¬ÔÓÐÒÔ´®¿ÚͨѶΪ»ù´¡µÄÓ¦ÓÃÈí¼þ£¬È糬¼¶Öն˵ȣ¬ÔÚWindowsϵÁвÙ×÷ϵͳϲ»ÐèÒª×÷Èκεĸü¸Ä¼´¿ÉʹÓᣠ|
VBUSģʽ |
VBUS¿ÉÒÔÈÃÒ»¸ö´®¿Ú¶ÔÓ¦Ò»µ½¶à¸öM1000´®¿Ú·þÎñÆ÷£¬ÌرðÊÊÓÃÓÚRS-485/422µÄÖ÷´Ó½á¹¹µÄÍøÂçµ½ÍøÂçµÄת±ä¡£ÌṩWindows ±ê×¼´®¿ÚÇý¶¯³ÌÐò£¬ÔÓÐÒÔ´®¿ÚͨѶΪ»ù´¡µÄÓ¦ÓÃÈí¼þ£¬ÔÚWindowsϵÁвÙ×÷ϵͳϲ»ÐèÒª×÷Èκεĸü¸Ä¼´¿ÉʹÓᣠ|
TCP Server/client ģʽ
|
Ö±½ÓʹÓÃsocket TCP·½Ê½±à³ÌºÍM1000´®¿Ú·þÎñÆ÷ͨѶ£¬»ñµÃ´®¿Ú¼°ÆäËüµÄÊý¾Ý¡£ |
UDP Server/client ģʽ
|
Ö±½ÓʹÓÃsocket UDP·½Ê½±à³ÌºÍM1000´®¿Ú·þÎñÆ÷ͨѶ£¬»ñµÃ´®¿Ú¼°ÆäËüµÄÊý¾Ý¡£ |
VBUS Root ģʽ |
ÊÊÓÃÓÚÖ÷´Ó½á¹¹µÄVBUSÍøÂç,´úÌæµçÄÔ×÷Ö÷»úµÄ¹¤×÷¡£ |
Pair Connection ³É¶Ôģʽ
|
Ö±½Ó½«Á½¸ö´®¿Úͨ¹ýÍøÂç¶Ô½Ó¡£ |
GROUP ģʽ |
ÊÊÓÃÓڶԵȽṹµÄÍøÂç,²ÉÓÃ×é¹ã²¥µÄ·½Ê½ÔÚͬ×éÄÚµÄM1000´®¿Ú·þÎñÆ÷½øÐÐͨѶ¡£ |
TCP/IP ½Ó¿Úģʽ
|
¿ª·ÅTCP/IP½Ó¿Ú£¬Óû§É豸ͨ¹ý´®Ðлò²¢ÐеĽӿÚÓëM1000´®¿Ú·þÎñÆ÷ͨѶ£¬°ÑËüµ±³ÉÓû§×Ô¼ºµÄÐÒéÕ»À´Ê¹Óᣠ|
INTERNETģʽ |
ÔÚINTERNETģʽ£¬Óû§¿ÉÒÔͨ¹ý»¥Á¬ÍøÖ±½Ó·ÃÎÊÔ¶³ÌµÄM1000´®¿Ú·þÎñÆ÷¡£ | | |
|
- °²È«µÄ·ÃÎÊ¿ØÖÆ £º¿ÉÒÔÉèÖõÄÖ÷»ú·ÃÎÊÁÐ±í£¬Ê¹É豸ÃâÊܲ»±ØÒªµÄ¹¥»÷£¬´ó´óÌá¸ßÉ豸µÄ°²È«ÐÔ¡£
- ·½±ãµÄÉèÖùÜÀí¹¤¾ß £º¿Éͨ¹ý´®Ðпڡ¢»Ö¸´³ö³§ÉèÖÿª¹Ø»òÉèÖÃÈí¼þMarsInstallerÀ´ÉèÖÃM1000µÄIPµØÖ·¼°²ÎÊý¡£
- Ç¿´óµÄ´¦ÀíÄÜÁ¦ £º¼«¸ßµÄÍøÂçÍÌÍÂÁ¿£¬ÔÚ¸´ÔÓµÄÍøÂçÖУ¬¿ÉÒÔ¿¹¾Ü´óÁ¿ÍøÂç°üµÄ¸ÉÈÅ¡£
- ÓÅÐãµÄÔÚÏßÉý¼¶ÄÜÁ¦ £º¿ÉÒÔ·½±ãµÄʵÏÖÔÚÏßÉý¼¶OS¼°WEB£¬Ãâ³ýÓû§Î¬»¤µÄ·³ÄÕ¡£
- ÏȽøµÄ´ò°ü·½Ê½ £º¿ÉÑ¡ÔñµÄ¶àÖÖ´ò°ü·½Ê½£¬Ê¹¿Í»§µÄ´®ÐÐÊý¾Ý°üÔÚÒ»¸öTCP/UDP°üÖС£
- ÌṩËùÓÐWindowsLinux´®¿ÚÇý¶¯³ÌÐò£¬ ´ËÍâÎÒ¹«Ë¾»¹¿ÉÒÔÐ޸Ĵ®¿Ú·þÎñÆ÷ÄÚ²¿µÄ·þÎñÈí¼þ£¬ÒÔÂú×ãÓû§µÄÌØÊâÒªÇó¡£
| |
|
|
|
Ó²¼þ |
|
´¦ÀíÆ÷ |
32λ |
Ö÷Ƶ |
133MHz |
ÄÚ´æ |
32M |
´®¿Ú |
RS-232 |
Íø¿Ú |
10/100 Mbps, RJ45 |
Ìå»ý |
90x60x21 mm | |
|
|
|
|
|
|
±ê×¼ |
802.11 b/g |
µç²¨ÆµÂÊÖÖÀà |
DSSS |
·¢Ë͹¦ÂÊ 11b |
18 dBm + 2 dBi |
·¢Ë͹¦ÂÊ 11g |
16 dBm + 2 dBi |
½ÓÊÕÁéÃô¶È |
-70 dBm @ 54 Mbps, -85 dBm @ 11Mbps |
´«ÊäËÙÂÊ |
54, 48, 36, 24, 18, 12, 11, 9, 6, 5.5, 2, 1 Mbps (×ÔÊÊÓ¦) |
´«Êä¾àÀë |
×î´ó300Ã× |
Êý¾Ý¼ÓÃÜ |
WEP 64-bit/128-bit |
ÌìÏß |
Reverse SMA |
ÍøÂçÀàÐÍ |
Infrastructure, Ad-Hoc | | |
|
|
|
½Ó¿Ú |
RS-232 |
ÐźŠ|
RS-232: TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND | |
|
|
|
ËÙÂÊ |
300---115200bps |
ÆæÅ¼Î»Ð£Ñé |
None, even, odd, space, mark |
Êý¾Ýλ |
5, 6, 7, 8 £¬9 |
ֹͣλ |
1, 1.5, 2 |
Á÷¿Ø |
RTS/CTS, XON/XOFF , DTR/DSR | |
|
|
|
|
|
|
Windowsƽ̨ |
Windows XP¡¢ Windows 2000¡¢ Windows98/ME | | |
|
|
|
µçÔ´¹æ¸ñ |
DC 12V/500mA |
¹¤×÷ÎÂ¶È |
-20 ¨C 55¡ãC |
¹¤×÷ʪ¶È |
5 - 95%RH£¬²»Äý¶ |
´¢´æÎÂ¶È |
-20 ¨C 85¡ãC | |
|
|
|
|
|
|
|
|
|
|
|
|