±±¾©µÂÀ¼ÏµÍ³¿ØÖÆÓÐÏÞ¹«Ë¾×¨ÒµÏúÊÛsteute·À±¬¿ª¹Ø£¬Ò½ÁƽÅ̤¿ª¹ØºÍ·À±¬´«¸ÐÆ÷µÈ
Æ·ÅÆ£º .Steute
Ãû³Æ£º ·À±¬ÃÅ¿ª¹Ø
Ðͺţº EEx 335 V.S
ÌØÐÔ¹¦ÄÜ
·À±¬1Çø£¬2Çø£¬21Çø£¬22Çø
°²×°·ûºÏDIN EN 50 041
½ÓÍ·¿ÉÒÔ4 x 90¡ã ¶¨Î»
Á¬½ÓÖá¿ÉÒÔ 360¡ã
Öá¿×Ö±¾¶ ø 10 mm
ÌØ±ð°æ±¾¿ÉÒÔÓÃÔÚ22Çø
¼¼Êõ²ÎÊý
Standards IEC/EN 60947-5-1; EN 1088; BG-GS-ET-15; EN 50014; EN 50018; EN 50019; EN 50281-1-1
Design mounting details to DIN EN 50 041
Enclosure zinc die casting, enamelled
Switch insert Ex 95
Protection class IP 65 according to IEC/EN 60529
Contact material silver
Switching system slow action, positive break NC contacts
Switching elements change-over contact with double break Zb or 2 NC contacts, galvanically separated contactbridges
Termination M3 screw clamps
Cable section max. 1.5 mm2 (incl. conductor ferrules)
Cable entry M20 x 1,5
Uimp 4 kV
Ui 250 V
Ithe 6 A
Ie/Ue 6 A/250 VAC; 0.25 A/230 VDC
Utilisation category AC-15, DC-13
Max. fuse rating 6 A gL/gG D-fuse
Ambient temperature ¨C20 ¡ãC ¡ +60 ¡ãC
Mechanical life > 1 million operations
Ex certification II 2G EEx de IIC T6, II 2D IP65 T80¡ãC
Approvals DMT 01 ATEX E 178