Ê×Ò³ - ÐÂÎÅ - ÕÐƸ - ÏÂÔØ - ²úÆ· - ³§ÉÌ - ·½°¸ - ÎÄÕª - Çó¹º - Õ¹ÀÀ
Ãâ·Ñ×¢²á µÇ¼ | ¹ã¸æ·þÎñ | ¿Í·þÖÐÐÄ
Öлª¹¤¿ØÍø ¡ú ¹¤¿Ø²úÆ· ¡ú MOXA NPort 5130 1¿ÚRS-422/485´®¿ÚÉ豸ÁªÍø·þÎñÆ÷
²úÆ·Ãû³Æ£º MOXA NPort 5130 1¿ÚRS-422/485´®¿ÚÉ豸ÁªÍø·þÎñÆ÷
ÐÍ ºÅ£º moxa nport 5130
¼Û ¸ñ£º 0.00
Æ· ÅÆ£º 78
 
Êղش˲úÆ·     ²é¿´ÊÕ²Ø
Ìṩ°üÀ¨TCP Server¡¢TCP Client¡¢UDP Server/ClientºÍ Ethernet ModemÔÚÄڵIJ»Í¬socket²Ù×÷ģʽ
Ò×ÓÚʹÓᢿÉÓÃÓÚÅúÁ¿°²×°µÄWindows¹¤¾ß
¿Éͨ¹ýÍøÂçWeb/Telnet½øÐÐÅäÖÃ
 
 
¸ÅÊö
 

ÔÚ´ó¶àÊýÓ¦ÓÃÖУ¬³¤¾àÀëµÄÊý¾Ý²É¼¯¶¼ÊDzÉÓÃRS-485¾Õ»¨Á´µÄ·½Ê½À´ÊµÏֵģ¬µ«ÊÇ´Óÿ¸öÉ豸¶ÁÈ¡Êý¾ÝÐèÒªºÄ·ÑµÄʱ¼ä±È½Ï³¤¡£ÎªÁ˸ÄÉÆÕâÖÖ×´¿ö£¬NPort 5130¿ÉÒÔ°ïÖú¼ÆËã»úÏòÿ¸öRS-485É豸·¢ËÍÃüÁî²¢ÇÒÔÚÒ»ÃëÖ®ÄÚ½ÓÊܵ½·µ»ØµÄÊý¾Ý£¬ÎÞÐèµÈ´ýÂÖѶ¡£

°²×°·½±ã
Ò²ÐíÄúʹÓõÄNPort 5130·Ö²¼ÔÚÍøÂçµÄ²»Í¬Î»Öã¬ËüÃÇÈ´¾ß±¸ÏàͬµÄÅäÖá£ÎªÁ˱ÜÃâÖظ´µÄ°²×°£¬MoxaÔÚÓÃÓÚ WindowsÖеÄNPort AdministratorÖÐÌṩÁË·½±ãÅúÁ¿°²×°µÄ¹¤¾ß¡£Óû§¿ÉÒÔͨ¹ýÑ¡ÔñËùÓÐÔÚÏßNPort¶ÔÆä×ö³ýÁËIP Ö®ÍâµÄËùÓвÎÊýÅäÖá£

¹ÊÕÏÅųý¸ü¼ÓÈÝÒ×
NPort 5130Ö§³ÖSNMP V2.0¡£Í¨¹ýʹÓÃSNMP Manager£¬Óû§¿ÉÒÔ¹Û²ìÍøÂçÉÏËùÓÐNPort 5130µÄ״̬¡£µ±NPort5 1 3 0 ·¢Éú´íÎóʱ£¨ Óû§¶¨ÒåµÄ£© £¬ Ëü»á×Ô¶¯Í¨ÖªSNMP Manager¡£³ý´ËÖ®Í⣬¸ÃÉ豸»¹ÎªÄÇЩ²»Ô¸Ê¹ÓÃSNMP managerµÄÓû§Ìṩemail±¨¾¯¹¦ÄÜ¡£ ͨ¹ýMoxaµÄWindows Utility»òweb console£¬Óû§¿ÉÒÔ×Ô¶¨Ò屨¾¯³ö·¢Ìõ¼þ¡£Óû§Êܵ½µÄ±¨¾¯°üÀ¨NPort 5130µÄÈÈÆô¶¯¡¢ÀäÆô¶¯»òÃÜÂë¸ü¸ÄµÈÐÅÏ¢¡£


 
Ìصã
µÍ³É±¾¡¢ÐÅÓÿ¨´óС
Ö§³ÖWindows/Linux COM´®¿ÚÇý¶¯³ÌÐòģʽ
Ìṩ°üÀ¨TCP Server¡¢TCP Client¡¢UDP Server/ClientºÍ Ethernet ModemÔÚÄڵIJ»Í¬socket²Ù×÷ģʽ
ÎÞÐèPC¡¢¿Éͨ¹ýÍøÂçÁ¬½ÓÁ½¸ö´®¿ÚÉ豸µÄ¶ÔµÈÁ¬½Óģʽ
Ò×ÓÚʹÓᢿÉÓÃÓÚÅúÁ¿°²×°µÄWindows¹¤¾ß
ËùÓÐÐźÅÄÚÖÃ15 KVÍ»²¨±£»¤
Ö§³ÖÍøÂç¹ÜÀíЭÒéSNMP MIB-II
¿Éͨ¹ýÍøÂçWeb/Telnet½øÐÐÅäÖÃ
 
 
 
¹æ¸ñ
LAN
ÒÔÌ«Íø
10/100 Mbps£¬RJ45£¬Auto MDI/MDIX
±£»¤
ÄÚ½¨1.5 KVµç´Å¸ôÀë
 
´®¿Ú½éÃæ
½éÃæ
RS-422/485
´®¿ÚÊý
1
¶Ë¿ÚÀàÐÍ
Male DB9
ÐźÅ
RS-422£ºTx£«¡¢Tx£­¡¢Rx£«¡¢Rx£­¡¢GND
RS-485£¨2Ïߣ©£ºData£«¡¢Data£­¡¢GND
RS-485£¨4Ïߣ©£ºTx£«¡¢Tx£­¡¢Rx£«¡¢Rx£­¡¢GND
Ðźű£»¤
15KV ESDÈ«Ðźű£»¤
RS-485Êý¾ÝÁ÷Ïò
ADDC™£¨×¨Àû±£»¤µÄÊý¾ÝÁ÷Ïò×Ô¶¯¿ØÖƹ¦ÄÜ£©
 
´®¿ÚͨѶ²ÎÊý
УÑéλ
None, Even, Odd, Space, Mark
Êý¾Ýλ
5, 6, 7, 8
ֹͣλ
1, 1.5, 2
Á÷¿Ø
RTS/CTS, XON/XOFF
²¨ÌØÂÊ
50 bps ~ 921.6 Kbps
 
Èí¼þÌØÐÔ
ЭÒé
ICMP, IP, TCP, UDP, DHCP, BOOTP, Telnet, DNS, SNMP, HTTP, SMTP
¹¤¾ß
NPort Administration Suite for Windows 95/98/ME/NT/2000/XP/2003/Vista
Çý¶¯Ö§³Ö
Windows 95/98/ME/NT/2000/XP/2003/XP x64/2003 x64 COM driver, Linux real TTY driver, SCO Unix,SCO OpenServer 5, UnixWare 7, UnixWare 2.1.x, SVR4.2,QNX
ÅäÖ÷½Ê½
Web/Serial/Telnet console, or Windows utility
 
µçÔ´ÐèÇó
µçÔ´ÊäÈë
12 to 48 VDC
¹¦ºÄ
200mA@12V£¬106mA@24V
µçÔ´±£»¤
1KV Burst(EFT)£¬EN61000-4-4
0.5 KV Surge£¬EN61000-4-5
 
»úе
²ÄÁÏ
ÂÁ (1 mm)
 
»·¾³
²Ù×÷ζÈ
0 ~ 55¡ãC (32 ~ 131¡ãF), 5 ~ 95% RH
-40 to 75¡ãC (-40 to 167¡ãF)£¬¿íÎÂÐͺÅ
´æ´¢Î¶È
-20 ~ 85¡ãC (-4 ~ 185¡ãF), 5 ~ 95% RH
 
°²¹æÈÏÖ¤
EMC
CE£ºEN55022 Class A/EN55024
FCC£ºFCC Part 15 Subpart B, Class A
°²È«
UL£ºUL60950-1£¬UL 508
T¨¹V£ºEN60950-1
MTBF
246505 hrs
±£ÐÞ
5Äê
 
 

¶©¹ºÐÅÏ¢
 
NPort 5130
1¿ÚRS-422/485´®¿ÚÉ豸ÁªÍø·þÎñÆ÷
ÒÔÉϲúÆ·Ìṩ
  • 1¿ÚNPort 5130´®¿ÚÉ豸ÁªÍø·þÎñÆ÷
  • µçÔ´ÊÊÅäÆ÷
  • ¿ìËÙ°²×°Ö¸ÄÏ
  • NPortÈí¼þ¹âÅ̼°Îĵµ
  •  
    Ñ¡¹ºÅä¼þ
    DK-35A
    µ¼¹ì°²×°Åä¼þ (35 mm)
     


    ¹«Ë¾¼ò½é
    ²úƷĿ¼
    ¹©Ó¦ÐÅÏ¢

    ¹«Ë¾Ãû³Æ£º º¼ÖÝͨ±¦¿Æ¼¼ÓÐÏÞ¹«Ë¾
    µç »°£º 0571 85353887 / ¶¡¿¤÷ë
    ´« Õ棺 0571-85353887
    µØ Ö·£º º¼ÖÝÊмÙɽ·99ºÅ5-1-901ÊÒ
    ÓÊ ±à£º 31000
    Ö÷ Ò³£º http://www.TBest.net

    ¸Ã³§ÉÌÏà¹Ø²úÆ·£º
  • ÏÖ»õ¹©Ó¦MOXA¿¨
  •  
  • ¹©Ó¦¸£ÖÝ̨Íåmoxaiks-6726-f-hvǧÕ׺ËÐĽ»»»»ú
  •  
  • ¹©Ó¦moxa uc-7410 plus uc-7420 plus ͨѶ¹ÜÀí»ú
  •  
  • ¹©Ó¦Ì¨ÍåMOXAIA241-lx IA240-lxͨѶ¹ÜÀí»ú
  •  
  • ¹©Ó¦Ì¨Íåmoxa´®¿Ú·þÎñÆ÷nport6650-8nport6650-16
  •  
  • ¹©Ó¦MOXANPort5610-16RS232´®¿Ú·þÎñÆ÷
  •  
  • ¹©Ó¦Ì¨Íåmoxa¿¨cp-168uRS232 PCI¶à´®¿Ú¿¨
  •  
  • ¹©Ó¦moxa¿¨cp-134u cp-134u-i RS485´®¿Ú¿¨
  •  
  • ¹©Ó¦Ì¨ÍåMOXA½»»»»úEDS-408A EDS-405AÒÔÌ«Íø½»»»»ú
  •  
  • ¹©Ó¦Ì¨ÍåMOXAEDS-308/305ÒÔÌ«Íø½»»»»ú
  •  
    ¸ü¶à²úÆ·...
      ¹ØÓÚÎÒÃÇ | ÁªÏµÎÒÃÇ | ¹ã¸æ·þÎñ | ±¾Õ¾¶¯Ì¬ | ÓÑÇéÁ´½Ó | ·¨ÂÉÉùÃ÷ | ·Ç·¨ºÍ²»Á¼ÐÅÏ¢¾Ù±¨  
    ¹¤¿ØÍø¿Í·þÈÈÏߣº0755-86369299
    °æȨËùÓÐ ¹¤¿ØÍø Copyright@ Gkong.com, All Rights Reserved