²úÆ·Ãû³Æ£º
|
ãü¸ñNS-206FC
|
|
ÐÍ ºÅ£º
|
NS-206FC
|
|
¼Û ¸ñ£º
|
|
|
Æ· ÅÆ£º
|
191
|
|
|
|
| ²úÆ·Ãû³Æ: |
NS-206FC |
| ²úÆ·½éÉÜ: |
2¿Ú¹âÏË(¶àÄ£SC)¡¢4¿Ú10/100M·Ç¹ÜÀíÐÍÒÔÌ«Íø½»»»»ú¡£
|
| ²úÆ·ÌØµã: |
×Ô¶¯Ê¶±ð MDI/MDI-X£¬¼´²å¼´Óà ÿ¸ö¶Ë¿Ú¾ùΪ 10/100M×ÔÊÊÓ¦ ´æ´¢×ª·¢»úÖÆ ȫ˫¹¤IEEE 802.3xºÍ°ëË«¹¤±³°åÁ÷¿ØÖÆ 1.6Gbps¸ßЧÄÜÄÚ´æ´ø¿í »º´æ¼ÇÒäÌå:256 Kbit Ö§³Ö 1KµÄ MAC µØÖ· 10~ 30V DC µçÔ´ÊäÈë ¹¤×÷ζÈΪ£º0 ~ 70¡ãC µ¼¹ì°²×°·½Ê½ |
| ²úÆ·²ÎÊý: |
¼¼Êõ ±ê×¼£º IEEE 802.3¡¢802.3uºÍ802.3x ´¦ÀíÀàÐÍ£º ´æ´¢×ª·¢, ÎÞÑÓÊ±ÍøËÙÇл» MACµØÖ·£º 1024 ÄÚ´æ´ø¿í£º 1.6 Gbps Á÷¿ØÖÆ£ºIEEE 802.3xÁ÷¿ØÖÆ, ·´ÏòѹÁ¦Á÷¿ØÖÆ ½Ó¿Ú RJ45½Ó¿Ú£º 10/100 Base-TX×ÔÊÊÓ¦, F/HË«¹¤Ä£Ê½, ×Ô¶¯MDI/MDI-X ¹âÏ˽ӿڣº100 Base-FX£¨¶àÄ££¬SC½ÓÍ·£© LEDÏÔʾ£º 10/100M, Link/Act, Full duplex/Half duplex(¹âÏ˽ӿÚ) Íø¿Ú¸ôÀ룺 1500 Vrms 1·ÖÖÓ Íâ¿ÇµØEMS±£»¤£º ÓÐ ¹âÏ˽ӿڣº¶àÄ£¹âÏË:50/125, 62.5/125 or 100/140 ¦Ìm ¾àÀë:2 km, (ÍÆ¼ö62.5/125 ¦Ìm)ȫ˫¹¤ ²¨³¤:1300»ò1310 ×îСTXÊä³ö: -20 dBm ×î´óTXÊä³ö: -14 dBm RXÁéÃô¶È: -34~-31 dBm ÒÔÌ«Íø´«Êä¾àÀ룺ÒÔÌ«Íø: 2-pair UTP/STP Cat.3,4,5, EIA/TIA-568 100-ohm ¸ßËÙÒÔÌ«Íø : 2-pair UTP/STP Cat. 5, EIA/TIA-568 100-ohm µçÔ´ ÊäÈëµçѹ£º 10 VAC ~ 30 VAC µçÔ´¹¦ÂÊ£º0.14A@24VDC£¬+/- 5% 100Mȫ˫¹¤ LEDÏÔʾ£ºÓÐ Íâ¿ÇµØEMS±£»¤£º ÓÐ ½Ó¿Ú:5-Pin¿ÉÒÆ¶¯¶Ë×Ó ÍâÐκͰ²×° Íâ¿Ç£ºËÜÁÏ ×èȼÐÔ£ºUL 94V-0 ÍâÐΣº 64mm x 110mm x 98mm (W x H x L) °²×°£º µ¼¹ì°²×° ¹¤×÷»·¾³ ¹¤×÷ζȣº 0 ¡ãC~ 70¡ãC ´æ´¢Î¶ȣº -20 ~ 85¡ãC »·¾³Êª¶È£º 10% ~ 90% ÎÞÀäÄý |
| ²úÆ·Ãû³Æ: |
NS-206FC |
| ²úÆ·½éÉÜ: |
2¿Ú¹âÏË(¶àÄ£SC)¡¢4¿Ú10/100M·Ç¹ÜÀíÐÍÒÔÌ«Íø½»»»»ú¡£
|
| ²úÆ·ÌØµã: |
×Ô¶¯Ê¶±ð MDI/MDI-X£¬¼´²å¼´Óà ÿ¸ö¶Ë¿Ú¾ùΪ 10/100M×ÔÊÊÓ¦ ´æ´¢×ª·¢»úÖÆ ȫ˫¹¤IEEE 802.3xºÍ°ëË«¹¤±³°åÁ÷¿ØÖÆ 1.6Gbps¸ßЧÄÜÄÚ´æ´ø¿í »º´æ¼ÇÒäÌå:256 Kbit Ö§³Ö 1KµÄ MAC µØÖ· 10~ 30V DC µçÔ´ÊäÈë ¹¤×÷ζÈΪ£º0 ~ 70¡ãC µ¼¹ì°²×°·½Ê½ |
| ²úÆ·²ÎÊý: |
¼¼Êõ ±ê×¼£º IEEE 802.3¡¢802.3uºÍ802.3x ´¦ÀíÀàÐÍ£º ´æ´¢×ª·¢, ÎÞÑÓÊ±ÍøËÙÇл» MACµØÖ·£º 1024 ÄÚ´æ´ø¿í£º 1.6 Gbps Á÷¿ØÖÆ£ºIEEE 802.3xÁ÷¿ØÖÆ, ·´ÏòѹÁ¦Á÷¿ØÖÆ ½Ó¿Ú RJ45½Ó¿Ú£º 10/100 Base-TX×ÔÊÊÓ¦, F/HË«¹¤Ä£Ê½, ×Ô¶¯MDI/MDI-X ¹âÏ˽ӿڣº100 Base-FX£¨¶àÄ££¬SC½ÓÍ·£© LEDÏÔʾ£º 10/100M, Link/Act, Full duplex/Half duplex(¹âÏ˽ӿÚ) Íø¿Ú¸ôÀ룺 1500 Vrms 1·ÖÖÓ Íâ¿ÇµØEMS±£»¤£º ÓÐ ¹âÏ˽ӿڣº¶àÄ£¹âÏË:50/125, 62.5/125 or 100/140 ¦Ìm ¾àÀë:2 km, (ÍÆ¼ö62.5/125 ¦Ìm)ȫ˫¹¤ ²¨³¤:1300»ò1310 ×îСTXÊä³ö: -20 dBm ×î´óTXÊä³ö: -14 dBm RXÁéÃô¶È: -34~-31 dBm ÒÔÌ«Íø´«Êä¾àÀ룺ÒÔÌ«Íø: 2-pair UTP/STP Cat.3,4,5, EIA/TIA-568 100-ohm ¸ßËÙÒÔÌ«Íø : 2-pair UTP/STP Cat. 5, EIA/TIA-568 100-ohm µçÔ´ ÊäÈëµçѹ£º 10 VAC ~ 30 VAC µçÔ´¹¦ÂÊ£º0.14A@24VDC£¬+/- 5% 100Mȫ˫¹¤ LEDÏÔʾ£ºÓÐ Íâ¿ÇµØEMS±£»¤£º ÓÐ ½Ó¿Ú:5-Pin¿ÉÒÆ¶¯¶Ë×Ó ÍâÐκͰ²×° Íâ¿Ç£ºËÜÁÏ ×èȼÐÔ£ºUL 94V-0 ÍâÐΣº 64mm x 110mm x 98mm (W x H x L) °²×°£º µ¼¹ì°²×° ¹¤×÷»·¾³ ¹¤×÷ζȣº 0 ¡ãC~ 70¡ãC ´æ´¢Î¶ȣº -20 ~ 85¡ãC »·¾³Êª¶È£º 10% ~ 90% ÎÞÀäÄý |
|
|
|