Ê×Ò³ - ÐÂÎÅ - ÕÐƸ - ÏÂÔØ - ²úÆ· - ³§ÉÌ - ·½°¸ - ÎÄÕª - Çó¹º - Õ¹ÀÀ
Ãâ·Ñ×¢²á µÇ¼ | ¹ã¸æ·þÎñ | ¿Í·þÖÐÐÄ
Öлª¹¤¿ØÍø ¡ú ¹¤¿Ø²úÆ· ¡ú MOXA NPort IA5000AϵÁÐ (ÐÂÆ·£¡)
²úÆ·Ãû³Æ£º MOXA NPort IA5000AϵÁÐ (ÐÂÆ·£¡)
ÐÍ ºÅ£º MOXA NPort IA5000AϵÁÐ (ÐÂÆ·£¡)
¼Û ¸ñ£º 0.00
Æ· ÅÆ£º 78
 
Êղش˲úÆ·     ²é¿´ÊÕ²Ø
1/2/4¿Ú¹¤Òµ¼¶´®¿ÚÉ豸ÁªÍø·þÎñÆ÷
 

Ìصã

  • ´®¿Ú¡¢Íø¿ÚºÍµçÔ´ÏßÌṩÀËÓ¿±£»¤
  • ´®¿ÚÖ§³Ö2KV¹âµç¸ôÀë±£»¤
  • µçÔ´½Ó¿ÚºÍ´®¿Ú½Ó¿ÚÖ§³ÖÂÝÐýÁ¬½Ó
  • ͨ¹ýC1D2ºÍATEXÈÏÖ¤£¬¿ÉÊÊÓÃÓÚ¶ñÁÓ»·¾³
  • ÒÔÌ«Íø¿Ú¿É¼¶Áª£¬½ÚÊ¡²¼Ïß
  • ÈßÓàµçÔ´ÊäÈë
  • Ò쳣ʼþʱ£¬×Ô¶¯·¢³öE-mailºÍ¼ÌµçÆ÷Êä³ö±¨¾¯
  • ÄÚǶMiiNe CPU£¬¹¦ºÄ½µµÍ
  • Ö§³Ö¿íÎÂ-40 ~ 75 ¡æ

°×ƤÊé
Demo Flash

¼ò½é

NPort IA5000A¹¤Òµ¼¶´®¿ÚÉ豸ÁªÍø·þÎñÆ÷ÊÇרΪÁ¬½Ó¹¤Òµ×Ô¶¯»¯´®¿ÚÉ豸£¬ÈçPLC¡¢´«¸ÐÆ÷¡¢ÒÇ±í¡¢µç»ú¡¢Çý¶¯Æ÷¡¢ÌõÂëÔĶÁÆ÷ºÍÏÔʾÆ÷µÈ¶øÉè¼ÆµÄ¡£NPort IA5000A¾ß±¸½ðÊôÍâ¿Ç¡¢ÂÝË¿Á¬½ÓÆ÷£¬²¢Ìṩȫ·½Î»ÀËÓ¿±£»¤ºÍÁ½ÖÖ°²×°·½Ê½¡£NPort IA5000AµÄ²Ù×÷½çÃæ·Ç³£ÓѺã¬ÈÃÄúµÄ´®¿ÚÁªÍø½â¾ö·½°¸±äµÃ¸ü¼òµ¥¡¢¸ü¿É¿¿¡£

ÒÔÌ«Íø¿Ú¼¶Áª£¬½µµÍ²¼Ï߳ɱ¾£¨½ö10/100Base TXÐͺţ©

NPort IA5000AµÄÁ½¸öÒÔÌ«Íø¿Ú¿É×÷ΪÒÔÌ«Íø½»»»»úµÄ¶Ë¿ÚʹÓá£Ò»¸ö¶Ë¿ÚÖ±½ÓÁ¬½Óµ½ÍøÂç»ò·þÎñÆ÷£¬ÁíÒ»¸ö¶Ë¿ÚÔòÓëÆäËûNPort IA»òÒÔÌ«ÍøÉ豸ÏàÁ¬¡£ÕâÖÖË«ÒÔÌ«Íø¿ÚµÄÉè¼Æ¿ÉÒÔ¼õÉÙÒòÿ̨´®¿ÚÉ豸Óë½»»»»úÁ¬½Ó¶ø²úÉúµÄ²¼Ï߳ɱ¾¡£

ÈßÓàµçÔ´ÊäÈë

NPort IA5000AÌṩÁ½¸öµçÔ´ÊäÈ룬¿ÉͬʱÁ¬½áÁ½¸öDCµçÔ´¡£Èç¹ûÆäÖÐÒ»¸öµçÔ´¶ÏÏߣ¬ÁíÒ»¸ö±¸ÓõçÔ´½«»á×Ô¶¯µØÇл»£¬À´Ö§³Ö NPort IA5000AËùÐèÒªµÄµçÁ¦¡£Á½¸öÊäÈëµçÔ´µÄÉè¼ÆÈ·±£ÄúµÄÉ豸²»¼ä¶ÏÔËÐС£

Ò쳣ʼþʱ£¬×Ô¶¯·¢³ö E-mail ºÍ¼ÌµçÆ÷Êä³ö±¨¾¯

Ò»µ©ÍøÂçÖжϡ¢µçÔ´¹ÊÕÏ£¬»ò´®¿ÚÐźŵÄDCDºÍDSR·¢Éú±ä»¯£¬ÄÚ½¨¼ÌµçÆ÷±¨¾¯»úÖƽ«»áÖ÷¶¯±¨¾¯£¬ÒÔÌáÐѹÜÀíÈËÔ±¡£´ËÍ⣬µ±Ò쳣ʼþ·¢Éúʱ£¬e-mailÒ²»áÖ÷¶¯·¢³ö±¨¾¯ÐÅÏ¢¡£ÕâЩ¹¦Äܽ«ÄÜ°ïÖúά»¤¹¤³ÌʦʵʱÏìÓ¦Èκνô¼±×´¿ö¡£

´®¿Ú¡¢Íø¿ÚºÍµçÔ´ÏßÌṩÀËÓ¿±£»¤

MoxaÁìÏȵÄÀËÓ¿±£»¤½â¾ö·½°¸£¬ÎªNPort® IA5000AÌṩ´®¿Ú¡¢Íø¿ÚºÍµçÔ´ÏßµÄÀËÓ¿±£»¤£¬²¢Í¨¹ýIEC 61000-4-5±ê×¼¡£ÕâÖÖÈ«·½Î»µÄÀËÓ¿±£»¤£¬¿ÉÒÔÈÃÄúµÄµçÆøÉ豸ԶÀëµçѹ±ä»¯»òµçÆøÔëÉùµÄ¸ÉÈÅ£¬ÊÊÓÃÓÚʯÓÍÌìÈ»ÆøºÍµçÁ¦×Ô¶¯»¯µÈÓ¦Óá£

¹¤ÒµµÈ¼¶ÈÏÖ¤

Ϊȷ±£²úÆ·°²È«£¬²¢ÔÚ¹¤Òµ»·¾³Öпɿ¿ÔËÐУ¬NPort® IA5000AÒÑ»ñµÃ¸÷ÖÖ¹¤ÒµÈÏÖ¤£¬Íâ¿Ç¾ß±¸IP30·À»¤µÈ¼¶£¬»¹Í¨¹ýUL508°²¹æÈÏÖ¤¡£´ËÍ⣬NPort® IA5000A»¹Í¨¹ýUL/cUL Class 1 Division 2 Groups A, B, C, DÈÏÖ¤µÄ·À±¬µÈ¼¶£¬Ö§³ÖATEX Class 1 Zone 2ÈÏÖ¤£¬¿ÉÊÊÓÃÓÚ¶ñÁÓ»·¾³¡£

 

ÒÔÌ«Íø ¶Ë¿ÚÊýÁ¿£º2
ËÙÂÊ£º10/100 Mbps, auto MDI/MDIX
Á¬½ÓÀàÐÍ£º8-pin RJ45
µç´Å¸ôÀë±£»¤£º1KV (level 2) surge protection
´®¿Ú ¶Ë¿ÚÊýÁ¿£ºNPort IA5150A£º1
NPort IA5250A£º2
NPort IA5450A£º4
´®¿Ú±ê×¼£ºRS-232/422/485
Á¬½ÓÀàÐÍ£ºNPort IA5150A£ºDB9 for RS-232, terminal block for RS-422/485
NPort IA5250A/IA5450A£ºDB9 for RS-232/422/485
´®¿ÚÏȱ£»¤£º• 15 KV ESD protection for all signals
• 2 KV isolation protection for Isolation models
• 1 KV (level 2) surge protection
RS-485Êý¾ÝÁ÷Ïë¿ØÖÆ£ºADDC® (Êý¾Ý×Ô¶¯¿ØÖÆ)
´®¿ÚͨѶ²ÎÊý Êý¾Ýλ£º5, 6, 7, 8
ֹͣλ£º1, 1.5, 2
УÑéλ£ºNone, Even, Odd, Space, Mark
Á÷¿Ø£ºRTS/CTS and DTR/DSR (RS-232 only), XON/XOFF
²¨ÌØÂÊ£º50 ~ 921.6 Kbps
´®¿ÚÐźŠRS-232£ºTxD, RxD, RTS, CTS, DTR, DSR, DCD, GND
RS-422£ºTx+, Tx-, Rx+, Rx-, GND
RS-485-4w£ºTx+, Tx-, Rx+, Rx-, GND
RS-485-2w£ºData+, Data-, GND
Èí¼þ ÍøÂçЭÒ飺ICMP, IP, TCP, UDP, DHCP, BOOTP, Telnet, Rtelnet, DNS, SNMP, HTTP, SMTP, SNTP, IGMP
ÅäÖù¤¾ß£ºWeb Console, Serial Console, Telnet Console, Windows Utility
Windows Real COMÇý¶¯£ºWindows 95/98/ME/NT/2000, Windows XP/2003/Vista/2008/7 x86/x64
Fixed TTYÇý¶¯£ºSCO Unix, SCO OpenServer, UnixWare 7, UnixWare 2.1, SVR 4.2, QNX 4.25, QNX 6, Solaris 10, FreeBSD, AIX 5.x, HP-UX 11i
Linux Real TTYÇý¶¯£ºLinux kernel 2.4.x, 2.6.x
»úеÌØÐÔ Íâ¿Ç£º½ðÊô
ÖØÁ¿£ºNPort IA5150A£º475 g
NPort IA5250A£º485 g
NPort IA5450A£º560 g
³ß´ç£ºNPort IA5150A/IA5250A£º36 x 105 x 140 mm (1.42 x 4.13 x 5.51 in)
NPort IA5450A£º45.8 x 134 x 105 mm (1.8 x 5.28 x 4.13 in)
¹¤×÷»·¾³ ¹¤×÷ζȣº±ê×¼Ðͺţº0 ~ 60¡ãC (32 ~ 140¡ãF)
¿íÎÂÐͺţº-40 ~ 75¡ãC (-40 ~ 167¡ãF)
¹¤×÷ʪ¶È£º5 ~ 95% RH
´æ´¢Î¶ȣº-40 ~ 85¡ãC (-40 ~ 185¡ãF)
µçÔ´ÐèÇó ÊäÈëµçѹ£º12 ~ 48 VDC
µçÔ´¹¦ºÄ£ºNPort IA5150A£º12 ~ 48 VDC; 220 mA @ 12 VDC, 110 mA @ 24 VDC
NPort IA5150AI£º12 ~ 48 VDC; 255 mA @ 12 VDC, 130 mA @ 24 VDC
NPort IA5250A£º12 ~ 48 VDC; 250 mA @ 12 VDC, 125 mA @ 24 VDC
NPort IA5250AI£º12 ~ 48 VDC; 290 mA @ 12 VDC, 150 mA @ 24 VDC
NPort IA5450A£º12 ~ 48 VDC; 374 mA @ 12 VDC, 184 mA @ 24 VDC
NPort IA5450AI£º12 ~ 48 VDC; 512 mA @ 12 VDC, 242 mA @ 24 VDC
°²¹æÈÏÖ¤ EMC£ºCE (EN55022 Class A, EN55024), FCC Part 15 Subpart B Class A
Safety£ºUL508 (Pending)
Hazardous Location£ºUL/cUL Class 1 Division 2 Groups A, B, C and D (Pending)
ATEX£ºClass I, Zone 2 (Pending)
EMS£ºEN61000-4-2 (ESD), Level 3
EN61000-4-3 (RS), Level 3
EN61000-4-4 (EFT), Level 4
EN61000-4-5 (Surge), Level 3
EN61000-4-6 (CS), Level 3
EN61000-4-8
EN61000-4-11
Shock£ºIEC60068-2-27
Freefall£ºIEC60068-2-32
Vibration£ºIEC60068-2-6
¿É¿¿ÐÔ ±¨¾¯£ºÄÚ½¨·äÃùÆ÷ºÍRTC (real-time clock)
×Ô¶¯ÖØÐÂÆô¶¯´¥·¢Æ÷£ºÄÚ½¨WDT (watchdog timer)
±£ÐÞ ±£ÐÞÆÚ£º5Äê

 

¿íÎÂÐͺÅ
²úÆ·±àºÅ ÃèÊö
NPort IA5250AI-T 2¿ÚRS-232/422/485¹¤Òµ¼¶´®¿ÚÉ豸ÁªÍø·þÎñÆ÷£¬Ö§³Ö´®¿Ú/Íø¿Ú/µçÔ´ÏßÀËÓ¿±£»¤£¬Á½¸öͬһIPµÄ10/100BaseT(X)¶Ë¿Ú£¬2KV¹âµç¸ôÀë±£»¤£¬-40 ~ 75¡æ¹¤×÷ζÈ
NPort IA5450A-T 4¿ÚRS-232/422/485¹¤Òµ¼¶´®¿ÚÉ豸ÁªÍø·þÎñÆ÷£¬Ö§³Ö´®¿Ú/Íø¿Ú/µçÔ´ÏßÀËÓ¿±£»¤£¬Á½¸öͬһIPµÄ10/100BaseT(X)¶Ë¿Ú£¬-40 ~ 75¡æ¹¤×÷ζÈ
NPort IA5450AI-T 4¿ÚRS-232/422/485¹¤Òµ¼¶´®¿ÚÉ豸ÁªÍø·þÎñÆ÷£¬Ö§³Ö´®¿Ú/Íø¿Ú/µçÔ´ÏßÀËÓ¿±£»¤£¬Á½¸öͬһIPµÄ10/100BaseT(X)¶Ë¿Ú£¬2KV¹âµç¸ôÀë±£»¤£¬-40 ~ 75¡æ¹¤×÷ζÈ
NPort IA5150AI-T 1¿ÚRS-232/422/485¹¤Òµ¼¶´®¿ÚÉ豸ÁªÍø·þÎñÆ÷£¬Ö§³Ö´®¿Ú/Íø¿Ú/µçÔ´ÏßÀËÓ¿±£»¤£¬Á½¸öͬһIPµÄ10/100BaseT(X)¶Ë¿Ú£¬2KV¹âµç¸ôÀë±£»¤£¬-40 ~ 75¡æ¹¤×÷ζÈ
NPort IA5250A-T 2¿ÚRS-232/422/485¹¤Òµ¼¶´®¿ÚÉ豸ÁªÍø·þÎñÆ÷£¬Ö§³Ö´®¿Ú/Íø¿Ú/µçÔ´ÏßÀËÓ¿±£»¤£¬Á½¸öͬһIPµÄ10/100BaseT(X)¶Ë¿Ú£¬-40 ~ 75¡æ¹¤×÷ζÈ
NPort IA5150A-T 1¿ÚRS-232/422/485¹¤Òµ¼¶´®¿ÚÉ豸ÁªÍø·þÎñÆ÷£¬Ö§³Ö´®¿Ú/Íø¿Ú/µçÔ´ÏßÀËÓ¿±£»¤£¬Á½¸öͬһIPµÄ10/100BaseT(X)¶Ë¿Ú£¬-40 ~ 75¡æ¹¤×÷ζÈ
±êÎÂÐͺÅ
²úÆ·±àºÅ ÃèÊö
NPort IA5450AI 4¿ÚRS-232/422/485¹¤Òµ¼¶´®¿ÚÉ豸ÁªÍø·þÎñÆ÷£¬Ö§³Ö´®¿Ú/Íø¿Ú/µçÔ´ÏßÀËÓ¿±£»¤£¬Á½¸öͬһIPµÄ10/100BaseT(X)¶Ë¿Ú£¬2KV¹âµç¸ôÀë±£»¤£¬0 ~ 60¡æ¹¤×÷ζÈ
NPort IA5250AI 2¿ÚRS-232/422/485¹¤Òµ¼¶´®¿ÚÉ豸ÁªÍø·þÎñÆ÷£¬Ö§³Ö´®¿Ú/Íø¿Ú/µçÔ´ÏßÀËÓ¿±£»¤£¬Á½¸öͬһIPµÄ10/100BaseT(X)¶Ë¿Ú£¬2KV¹âµç¸ôÀë±£»¤£¬0 ~ 60¡æ¹¤×÷ζÈ
NPort IA5450A 4¿ÚRS-232/422/485¹¤Òµ¼¶´®¿ÚÉ豸ÁªÍø·þÎñÆ÷£¬Ö§³Ö´®¿Ú/Íø¿Ú/µçÔ´ÏßÀËÓ¿±£»¤£¬Á½¸öͬһIPµÄ10/100BaseT(X)¶Ë¿Ú£¬0 ~ 60¡æ¹¤×÷ζÈ
NPort IA5150A 1¿ÚRS-232/422/485¹¤Òµ¼¶´®¿ÚÉ豸ÁªÍø·þÎñÆ÷£¬Ö§³Ö´®¿Ú/Íø¿Ú/µçÔ´ÏßÀËÓ¿±£»¤£¬Á½¸öͬһIPµÄ10/100BaseT(X)¶Ë¿Ú£¬0 ~ 60¡æ¹¤×÷ζÈ
NPort IA5150AI 1¿ÚRS-232/422/485¹¤Òµ¼¶´®¿ÚÉ豸ÁªÍø·þÎñÆ÷£¬Ö§³Ö´®¿Ú/Íø¿Ú/µçÔ´ÏßÀËÓ¿±£»¤£¬Á½¸öͬһIPµÄ10/100BaseT(X)¶Ë¿Ú£¬2KV¹âµç¸ôÀë±£»¤£¬0 ~ 60¡æ¹¤×÷ζÈ
NPort IA5250A 2¿ÚRS-232/422/485¹¤Òµ¼¶´®¿ÚÉ豸ÁªÍø·þÎñÆ÷£¬Ö§³Ö´®¿Ú/Íø¿Ú/µçÔ´ÏßÀËÓ¿±£»¤£¬Á½¸öͬһIPµÄ10/100BaseT(X)¶Ë¿Ú

 


¹«Ë¾¼ò½é
²úƷĿ¼
¹©Ó¦ÐÅÏ¢

¹«Ë¾Ãû³Æ£º ±±¾©À¶²©Ô¶Ñï¿Æ¼¼·¢Õ¹ÓÐÏÞ¹«Ë¾
µç »°£º 010 62632232 82483045 / Ñî֥Ȩ
´« Õ棺 010-82483351
µØ Ö·£º ±±¾©Êк£µíÇøÖйشå´ó½ÖEÊÀ½ç²Æ¸»ÖÐÐÄA×ùA631
ÓÊ ±à£º 100086
Ö÷ Ò³£º http://www.lbyy2008.com

¸Ã³§ÉÌÏà¹Ø²úÆ·£º
  • MOXA UPort 1450ϵÁÐ
  •  
  • MOXA UPort 1250/1250I
  •  
  • MOXA UPort™ 1150/1150I
  •  
  • MOXA UPort 1130
  •  
  • MOXA UPort 1610-16
  •  
  • MOXA UPort 1610-8/1650-8
  •  
  • MOXA UPort 1400ϵÁÐ
  •  
  • MOXA UPort 1110 (ÐÂÆ·£¡)
  •  
  • MOXA UPort™ 2410
  •  
  • moxa UPort™ 2210
  •  
    ¸ü¶à²úÆ·...
      ¹ØÓÚÎÒÃÇ | ÁªÏµÎÒÃÇ | ¹ã¸æ·þÎñ | ±¾Õ¾¶¯Ì¬ | ÓÑÇéÁ´½Ó | ·¨ÂÉÉùÃ÷ | ·Ç·¨ºÍ²»Á¼ÐÅÏ¢¾Ù±¨  
    ¹¤¿ØÍø¿Í·þÈÈÏߣº0755-86369299
    °æȨËùÓÐ ¹¤¿ØÍø Copyright@ Gkong.com, All Rights Reserved