¼ò½é
NPort 5600-8-DTµÄ×ÀÃæÐÍ´®¿ÚÁªÍø·þÎñÆ÷¾ß±¸8¸öÈýºÏÒ»´®¿Ú£¬Ö§³ÖRS-232/422/485£¬ÊÇÄúÔÚPOS¡¢¹¤³§×Ô¶¯»¯¡¢·ÖɢʽEMSϵͳµÈÓ¦ÓõIJ»¶þÑ¡Ôñ¡£
NPort 5600-8-DTÏà±È´«Í³µÄ19''»ú¼ÜÐͲúÆ·ÏԵøüΪ½ô´Õ£¬ÈçÏÖ³¡²»Ìṩµ¼¹ì°²×°£¬¹¤³Ìʦ¾Í¿ÉÒÔ²ÉÓÃNPort 5600-8-DTÕâÖÖ×ÀÃæÐ͵IJúÆ·£¬ÒÔʵÏÖ´®¿ÚÁªÍøµÄ¹¦ÄÜ¡£
רΪRS-485Ó¦ÓöøÉè¼Æ
NPort 5650-8-DTϵÁÐÖ§³Ö¿ÉÑ¡1K¦¸/150K¦¸ ÉÏÀÏÂÀµç×èºÍ120¦¸Öն˵ç×è¡£ÔÚһЩÌØÊâ»·¾³ÖУ¬´®¿ÚÐźŵķ´Éä¼°¸ÉÈŽϴ󣬾³£»áÓ°Ï쵽ͨѶЧ¹û¡£ÕâʱÎÒÃÇÐèҪʹÓÃÖն˵ç×èÒÔ×èÖ¹´®¿ÚÐźŵķ´É䡣ͬʱÐźÅËðºÄ¼°Æ¥ÅäÊÇÁíÒ»¸öÄÑÌ⣬ÕýÈ·µØÉèÖÃÉÏÀÏÂÀµç×è¿ÉÒÔÓÐЧ·ÀÖ¹ÕâЩÎÊÌâµÄ²úÉú¡£NPort 5600´®¿ÚÉ豸·þÎñÆ÷ÔÚÿ¸ö´®¿ÚÉ϶¼ÉèÖõĿɵ÷ʽµç×裬ÔÊÐí¿Í»§Í¨¹ýÌøÏßÀ´µ÷½ÚÖն˵ç×裬ͨ¹ý²¦Â뿪¹ØÀ´µ÷½ÚÉÏÀÏÂÀµç×èµÄ×èÖµ¡£²¢Ìرð¶ÔËùÓÐÐźÅÏßÌṩÌṩ2KV¹âµç¸ôÀë±£»¤¡£
±ãÀûµÄµçÔ´ÊäÈë
NPort 5650-8-DT¿Éͨ¹ýÖն˶Ë×Ó»òPower Jack½øÐеçÔ´ÊäÈë¡£Óû§¿ÉÒÔÖ±½Ó½«Öն˶Î×ÓÁ¬½ÓÖÁDCµçÔ´£¬Ò²¿ÉʹÓÃPower Jackͨ¹ýµçÔ´ÊÊÅäÆ÷
Ìصã
- Ìṩ8¸öRS-232/422/485ÈýºÏÒ»´®¿Ú
- ½ô´ÕµÄ×ÀÃæÐÍÉè¼Æ
- 10/100M ×ÔÊÊÓ¦ÒÔÌ«Íø
- ËùÓд®¿ÚÐźŴø15KV ESD±£»¤
- ͨ¹ýLCMÏÔʾÒ×ÓÚÅäÖÃIPµØÖ·
- Ìṩweb£¬telnet console½øÐÐÉèÖÃ
- ÌṩTCP Server£¬TCP Client£¬UDPºÍDriverģʽ
- ÌṩSNMP MIB-IIÀ´ÌṩÍøÂç¹ÜÀí
LAN ÒÔÌ«Íø£º2 10/100 Mbps£¬RJ45
±£»¤£ºÄÚǶµÄ1.5 KVµç´Å¸ôÀë
NPort 5610-8-DT´®¿Ú½éÃæ ½Ó¿Ú£ºRS-232
½Ó¿ÚÊýÁ¿£º8
½Ó¿ÚÀàÐÍ£ºRJ45 (8-pin) »ò DB9 (male)
ÐźţºTxD£¬RxD£¬RTS£¬CTS£¬DTR£¬DSR£¬DCD£¬GND
NPort 5650-8-DT´®¿Ú½éÃæ
½Ó¿Ú£ºRS-232/422/485
½Ó¿ÚÊýÁ¿£º8
½Ó¿ÚÀàÐÍ£ºRJ45 (8-pin) »ò DB9 (male)
Ðźţº
RS-232£ºTxD£¬RxD£¬RTS£¬CTS£¬DTR£¬DSR£¬DCD£¬GND
RS-422£ºTx+£¬Tx-£¬Rx+£¬Rx-£¬GND
RS-485 (2Ïß)£ºData+£¬Data-£¬GND
RS-485 (4Ïß)£ºTx+£¬Tx-£¬Rx+£¬Rx-£¬GND
Ðźű£»¤£ºËùÓÐÐźÅÌṩ15 KV ESD±£»¤
Ðźű£»¤£º2 KV (NPort 5650I-8-DT)
RS-485Êý¾ÝÁ÷Ïò£ºADDC8482;£¨×¨Àû±£»¤µÄÊý¾ÝÁ÷Ïò×Ô¶¯¿Ø
Öƹ¦ÄÜ£©
µçÔ´Ïß±£»¤ 4 KV burst (EFT)£¬EN61000-4-4
2 KV surge£¬EN61000-4-5
ÄÚǶ¸ß¼¶¹¦ÄÜ HMI£ºLCMÏÔʾ£¬´ø4¸ö°´¼ü
ÄÚǶµÄ·äÃùÆ÷
ÄÚǶʵʱʱÖÓ
ÄÚǶ¿´ÃŹ·ÊµÊ±Ê±ÖÓ
´®ÐÐͨÐŲÎÊý УÑéλ£ºNone£¬Even£¬Odd£¬Space£¬Mark
Êý¾Ýλ£º5£¬6£¬7£¬8
ֹͣλ£º1£¬1.5£¬2
Á÷Ïò¿ØÖÆ£ºRTS/CTS£¬XON/XOFF£¬DSR/DTR (½öRS-232)
ËÙÂÊ£º50 bps ~ 921.6 Kbps
Èí¼þÌصã ÐÒ飺ICMP£¬IP£¬TCP£¬UDP£¬DHCP£¬BOOTP£¬Telnet£¬DNS£¬
SNMP£¬HTTP£¬SMTP£¬SNTP£¬Rtelnet£¬ARP£¬RFC2217
¹¤¾ß£ºNPort¹ÜÀíÔ±Ó¦ÓÃÓÚWindows 95/98/ME/NT/2000/
XP/2003/Vista
Çý¶¯Ö§³Ö£ºWindows 95/98/ME/NT/2000//XP/2003/2003
x64/Vista/Vista x64 Real COM driver/Linux Real TTY
driver/SCO Unix/SCO OpenServer 5/OpenServer 6/
UnixWare7/UnixWare 2.1/SVR4.2/QNX 4.25/QNX 6/
Solaris 10/FreeBSD 5/FreeBSD 6
ÅäÖãºWebä¯ÀÀÆ÷/´®¿Útelnet console¿Ú£¬»òWindows¹¤¾ß
µçÔ´ÐèÇó µçÔ´ÊäÈ룺12 ~ 48 VDC
µçÔ´¹¦ºÄ£º
NPort 5610-8-DT£º 621 mA for 12V£¬140 mA for 48V
NPort 5610-8-DT-J£º 621 mA for 12V£¬140 mA for 48V
NPort 5650-8-DT£º 580 mA for 12V£¬156 mA for 48V
NPort 5650I-8-DT£º 1066 mA for 12V£¬200 mA for 48V
NPort 5650-8-DT-J£º 580 mA for 12V£¬156 mA for 48V
»úеÌØÐÔ ²ÄÁÏ£ºSECC¸Ö°å (1mm)
³ß´ç (W ¡Á H ¡Á D)£º
197 x 135.5 x 44 mm (ÎÞ ears)
229 x 135.5 x 46 mm (º¬ ears)
197 x 135.5 x 53 mm (with DIN-Rail kit on bottom panel)
ëÖØ£º
NPort 5610-8-DT£º 1.76 kg
NPort 5610-8-DT-J£º 1.17 kg
NPort 5650-8-DT£º 1.77 kg
NPort 5650I-8-DT£º 1.85 kg
NPort 5650-8-DT-J£º 1.71 kg
¹¤×÷»·¾³ ¹¤×÷ζȣº0 ~ 55 ¡ãC (32 ~ 131 ¡ãF)£¬5 ~ 95% RH
´æ´¢Î¶ȣº-20 ÖÁ 70¡ãC (-4 ÖÁ 158¡ãF)£¬5 ÖÁ 95% RH
ͨ¹ýÈÏÖ¤ EMC£º
CE: EN55022 Class A/EN55024
FCC: FCC Part 15 Subpart B£¬Class A
°²È«£º
UL: UL60950-1
TÜV: EN60950-1
±£ÐÞÆÚ5 Äê