4¿ÚRS-232/422/485 IEEE 802.11b/gÉ豸ÎÞÏßÁªÍø·þÎñÆ÷
¼ò½é
ʹÓÃ802.11b/gÀ©Õ¹´®¿ÚÉ豸µÄÎÞÏßÁªÍøÄÜÁ¦
¶ÔÓÚ²»±ãÓÚ½ÓÏßµÄÇé¿ö£¬´®¿ÚÉ豸ÎÞÏßÁªÍø·þÎñÆ÷ÊÇ×îÀíÏëµÄ½â¾ö·½°¸¡£µ±Ê¹Óûù±¾½á¹¹Ä£Ê½»òÕ߶ԵÈģʽʱ£¬¿Éͨ¹ýÒ»¸öÎÞÏß½ÓÈëµã»òÕßÁíÒ»¸öNPort® W2004ÓëÉ豸½øÐÐͨѶ¡£ÔÚ¿ªÀ«ÇøÓòͨѶ¾àÀë¿É´ï300Ãס£
ʹÓÃÄúÒÑÓеÄÈí¼þ£¬½Úʡʱ¼äºÍ³É±¾
NPort® W2004µÄReal COM/TTYÇý¶¯³ÌÐòÖ§³ÖWindowsºÍLinuxϵͳ£¬È·±£Ê¹ÓÃÐÂÐÍÎÞÏß¾ÖÓòÍøÉ豸ʱ£¬ÏÖÓеÄÈí¼þÈÔ¿ÉÒÔʹÓá£Í¬Ê±£¬ËüÒ²Ö§³ÖTCP·þÎñÆ÷ģʽ£¬TCP¿Í»§¶ËģʽºÍUDPģʽ£¬Òò´Ë»ùÓÚIPµÄÈí¼þ (ÀýÈçTelnet) ¿ÉÒÔͨ¹ýÒÑÖªµÄIPµØÖ·ºÍ¶Ë¿ÚºÅÖ±½Ó·ÃÎÊÿ¸öÉ豸¡£
ʹÓð²È«µÄSSH/SSL½øÐÐÔ¶³ÌÅäÖú͹ÜÀí
ϵͳ¹ÜÀíÔ±×îÍ·ÌÛµÄÊÇ·Ç·¨·ÃÎÊ¡£NPor t® W2004³ýÁËWEP¼¼Êõ£¬IP¹ýÂ˺ÍÃÜÂë¿ÉÒÔ±£»¤ÎÞÏß¾ÖÓòÍøÍ⣬»¹¿ÉÒÔʹÓÃSSHºÍSSLÌṩµÄ¶îÍâ±£»¤£¬²»ÖÂÊܵ½ºÚ¿ÍµÄ¹¥»÷¡£Í¬Ñù£¬Ê¹ÓÃÒ»¸öÖ§³ÖhttpsÐÒéµÄÍøÂçä¯ÀÀÆ÷ (ÀýÈ磺Internet Explorer)£¬»òÕßÒ»¸öÖ§³ÖSSHµÄÖն˷ÂÕæÆ÷£¨ÀýÈ磺PuTTY£©¾Í¿ÉÒÔ°²È«µÄ²ì¿´NPort® W2004µÄÍøÒ³»ò»ùÓÚÎı¾µÄÅäÖò˵¥¡£
Ìصã
- Á¬½ÓÈÎÒâ´®¿ÚÉ豸µ½802.11b/gÍøÂç
- 4¸öRS-232/422/485´®¿Ú£¬×î¸ßËÙÂÊ¿É´ï460.8 Kbps
- »ùÓÚÍøÂçµÄÅäÖ÷½Ê½£¬¿Éͨ¹ýÄÚÖõÄÒÔÌ«Íø»òÕßWLANÅäÖÃ
- Ö§³ÖWindow/Linux´®¿ÚÇý¶¯³ÌÐòģʽ
- Ö§³ÖTCP·þÎñÆ÷ģʽ£¬TCP¿Í»§¶ËģʽºÍUDPģʽ
- Ö§³ÖHTTPS£¬SSHÈÏÖ¤£¬¿ÉÌá¸ßÔ¶³ÌÅäÖõݲȫÐÔ
ÒÔÌ«Íø½Ó¿Ú ÒÔÌ«Íø£º10/100 M£¬RJ45£¬×Ô¶¯MDI/MDIX
µç´Å±£»¤£ºÄÚÖÃ1.5 KV
ÎÞÏß¾ÖÓòÍø
±ê×¼£ºIEEE 802.11b/g
ÐźÅÀàÐÍ£ºDSSS/OFDM
·¢É书ÂÊ
802.11b£º×î´ó20 dBm
802.11g£º×î´ó18 dBm
½ÓÊÕÁéÃô¶È£º-80 dBm
´«ÊäËÙÂÊ£º54 Mbps (×î´ó) ËÙÂÊ×Ô¶¯»ØÍË (54£¬48£¬36£¬24£¬
18£¬12£¬11£¬9£¬6£¬5.5£¬2£¬1 M)
´«Êä¾àÀ룺×î´ó300Ã× (@12Mbps£¬¿ªÀ«ÇøÓò)
ÌìÏßÁ¬½ÓÆ÷£º·´ÏàSMA
ÍøÂçģʽ£º»ù±¾½á¹¹Ä£Ê½£¬¶ÔµÈģʽ
°²È«ÐÔ£ºWEP 64λ/128λÊý¾Ý¼ÓÃÜ
´®¿Ú ±ê×¼£ºRS-232/422/485
ÊýÁ¿£º4¸ö
½ÓÍ·£ºRJ45£¬ËùÓд®¿ÚÌṩ15KV ESD±£»¤
¿ØÖÆ̨¶Ë¿Ú£ºRS-232¿ØÖÆ̨¶Ë¿Ú
RS-485Êý¾Ý·½Ïò¿ØÖÆ£ºADDC8482; (רÀû)
´®¿ÚͨѶ²ÎÊý Êý¾Ýλ£º5£¬6£¬7£¬8
ֹͣλ£º1£¬1.5£¬2
УÑéλ£ºNone£¬Even£¬Odd£¬Space£¬Mark
Á÷Á¿¿ØÖÆ£ºRTS/CTS£¬XON/XOFF
ËÙÂÊ£º50 bps ~ 460.8 K bps
´®ÐÐÐźŠRS-232£ºTxD£¬RxD£¬RTS£¬CTS£¬DTR£¬DSR£¬DCD£¬GND
RS-422£ºTx+£¬Tx-£¬Rx+£¬Rx-£¬GND
RS-485 (2Ïß)£ºData+£¬Data-£¬GND
RS-485 (4Ïß)£ºTx+£¬Tx-£¬Rx+£¬Rx-£¬GND
Èí¼þÌصã ÐÒ飺 ICMP, IP, TCP, UDP, DHCP, Telnet, DNS, SNMP,
HTTP, SMTP, SNTP, SSH, HTTPS
ÅäÖãºWeb Console, Serial Console, Telnet Console
ÅäÖù¤¾ß£ºNPort® Search UtilityºÍNPort® Windows Driver
manager
Çý¶¯Ö§³Ö£ºWindows Real COM driver (for Windows 95,
98, ME, NT, 2000, XP, 2003, Vista, XP x64, 2003 x64,
Vista x64), Linux Real TTY driver, Fixed TTY driver (for
SCO Unix, SCO OpenServer, UnixWare 7, UnixWare 2.1,
SVR 4.2, QNX 4.25, QNX 6, Solaris 10, FreeBSD, AIX 5.x,
HP-UX 11i)
ÎïÀíÌØÐÔ Íâ¿Ç£ºSECC¸Ö°å (1 mm) IP30µÈ¼¶±£»¤
ÖØÁ¿£º873 g
³ß´ç£º ÎÞÌìÏߣº45.8 x 135 x 105 mm (1.80 x 5.31 x 4.13 in)
º¬ÌìÏߣº45.8 x 204 x 142 mm (3.94 x 8.03 x 5.59 in)
»·¾³²ÎÊý ¹¤×÷ζȣº0 ~ 60 ¡ãC (32 ~ 140 ¡ãF)
¹¤×÷ʪ¶È£º5 ~ 95%RH
´æ´¢Î¶ȣº-20 ~ 85 ¡ãC (-4~185 ¡ãF)
µçÔ´ÐèÇó µçÔ´ÊäÈ룺12 ~ 48 VDC
µçÔ´¹¦ºÄ£º685 mA @ 12 V£¬340 mA @ 48 V£¬184 mA @ 24 V
°²¹æÈÏÖ¤ EMC£ºCE (EN55022ºÍEN55024 Class A£¬ETSI EN 301
489-17, ETSI EN 301 489-1), FCC (Part 15 Subpart C,
Part 17 Subpart B Class A)
°²È«£ºUL (UL60950-1)£¬TÜV (EN60950-1)
¿É¿¿ÐÔ MTBF£º81,501 hours
±£ÐÞÆÚ£º5Äê