·ûºÏIEC 61850-3ºÍEN50155±ê×¼µÄ¹âµçת»»Æ÷
 

¼ò½é

PTC-101Ö§³Ö10/100BaseT(X)ºÍ100BaseFXÖ®¼äµÄÐźÅת»»£¬ÅäÖÃSC, ST»òLC½Ó¿Ú¡£PTC-101ÎÞÐè¶îÍâ²¼Ïߣ¬Ö§³ÖIEEE 802.3ÒÔ¼°IEEE 802.3u±ê×¼£¬È«/°ëË«¹¤£¬×Ô¶¯¼ì²âMDI/MDI¨CX£¬ÎªÄúÌṩÍêÕûµÄ¹¤ÒµÒÔÌ«Íø½â¾ö·½°¸¡£

Ìصã

  • ×ÔÊÊÓ¦10/100BaseT(X) ºÍMDI/MDI-X×Ô¶¯Õì²â
  • Link Fault Pass-Through£¨LFP£©
  • µçÔ´¹ÊÕÏʱ£¬¼ÌµçÆ÷Êä³ö¾¯±¨£¨½öLVÐͺţ©
  • ¹¤×÷ζÈ-40 ~ 85 ¡ãC
  • ÈßÓàË«Ö±Á÷µçÔ´ÊäÈë
  • ¼¯³É¸ß¿É¿¿ÐÔµçÔ´£¬ÎÞÐèÍâ½ÓµçԴת»»Æ÷

¼¼Êõ ±ê×¼£º
IEEE 802.3 for 10BaseT
IEEE 802.3u for 100BaseT(X), 100BaseFX
½Ó¿Ú RJ45¿Ú£º10/100BaseT(X)
¹â¿Ú£º100BaseFX (SC/ST/LC½Ó¿Ú)
LEDָʾµÆ PTC-101-HVϵÁУºPWR1, Fiber Link, 10/100M (TP port)
PTC-101-LVϵÁУºPWR1, PWR2, Fiber Link, 10/100M
(TP port)
DIP ¿ª¹Ø

±¨¾¯´¥µã£ºÒ»Â·¼ÌµçÆ÷Êä³ö£¬µçÁ÷¸ºÔØΪ1 A@ 24 VDC
¹âÏË

»úеÌØÐÔ Íâ¿Ç£ºÂÁ£¬IP30·À»¤µÈ¼¶
³ß´ç£º122.5 x 90 x 20 mm (4.82 x 3.54 x 0.79 in)
ÖØÁ¿£º
²úÆ·¾»ÖØ£º690 g
°ü×°ÖØÁ¿£º875 g
¹¤×÷»·¾³ ²Ù×÷ζȣº-40 ~ 85 ¡ãC (-40 ~ 185 ¡ãF)
¹¤×÷ʪ¶È£º5 ~ 95% RH
´¢´æζȣº-40 ~ 85 ¡ãC (-40 ~ 185 ¡ãF)
µçÔ´ÒªÇó ÊäÈëµçѹ£º

½Ó¿Ú£º¿É²å°ÎµÄ½ÓÏ߶Ë×Ó
¹ýÔصçÁ÷±£»¤£º1.6A£¨ÐźŶ̽ӱ£»¤£©
·´½Ó±£»¤£ºÓÐ
°²¹æÈÏÖ¤ °²È«£ºUL 60950-1
EMI£ºFCC Part 15, CISPR (EN55022) class A
EMS£º
EN61000-4-2 Edition 1.2£º2001-04 (Level 4)
EN61000-4-3£º1995+A1£º2001
IEC 61000-4-3£º2002+A1£º2002 (Level 3)
EN61000-4-4£º2004 (Level 4)
EN61000-4-5£º2001-04 (Level 4)
EN61000-4-6£º2004-11 (Level 3)
EN61000-4-8£º2001-03 (Level 5)
EN61000-4-11£º2004-03 (Criteria B)
µçÁ¦×Ô¶¯»¯£ºIEC 61850-3, IEEE 1613
¹ìµÀ½»Í¨£ºEN50155/EN50121-4
×¢£ºÏêÇé²Î¼û¡°»·¾³²âÊÔ±í¡±
±£ÐÞ ±£ÐÞÆÚ£º5 Äê

 

¿ÉÑ¡ÐͺÅ
²úÆ·±àºÅ ÃèÊö
PTC-101-S-ST-HV 10/100BaseT(X)ת100BaseFX¹âµçת»»Æ÷£¬µ¥Ä££¬ST½ÓÍ·£¬1·¶ÀÁ¢µçÔ´(88-300 VDC»ò85-264 VAC)£¬²Ù×÷ζÈ-40 ~ 85 ¡ãC
PTC-101-S-LC-HV 10/100BaseT(X)ת100BaseFX¹âµçת»»Æ÷£¬µ¥Ä££¬LC½ÓÍ·£¬1·¶ÀÁ¢µçÔ´(88-300 VDC»ò85-264 VAC)£¬²Ù×÷ζÈ-40 ~ 85 ¡ãC
PTC-101-M-ST-HV 10/100BaseT(X)ת100BaseFX¹âµçת»»Æ÷£¬¶àÄ££¬ST½ÓÍ·£¬1·¶ÀÁ¢µçÔ´(88-300 VDC»ò85-264 VAC)£¬²Ù×÷ζÈ-40 ~ 85 ¡ãC
PTC-101-M-LC-HV 10/100BaseT(X)ת100BaseFX¹âµçת»»Æ÷£¬¶àÄ££¬LC½ÓÍ·£¬1·¶ÀÁ¢µçÔ´(88-300 VDC»ò85-264 VAC)£¬²Ù×÷ζÈ-40 ~ 85 ¡ãC
PTC-101-S-SC-HV 10/100BaseT(X)ת100BaseFX¹âµçת»»Æ÷£¬µ¥Ä££¬SC½ÓÍ·£¬1·¶ÀÁ¢µçÔ´(88-300 VDC»ò85-264 VAC)£¬²Ù×÷ζÈ-40 ~ 85 ¡ãC
PTC-101-S-LC-LV 10/100BaseT(X)ת100BaseFX¹âµçת»»Æ÷£¬µ¥Ä££¬LC½ÓÍ·£¬Ë«ÈßÓàµçÔ´ÊäÈë(20-70 VDC)£¬²Ù×÷ζÈ-40 ~ 85 ¡ãC
PTC-101-S-ST-LV 10/100BaseT(X)ת100BaseFX¹âµçת»»Æ÷£¬µ¥Ä££¬ST½ÓÍ·£¬Ë«ÈßÓàµçÔ´ÊäÈë(20-70 VDC)£¬²Ù×÷ζÈ-40 ~ 85 ¡ãC
PTC-101-M-SC-HV 10/100BaseT(X)ת100BaseFX¹âµçת»»Æ÷£¬¶àÄ££¬SC½ÓÍ·£¬1·¶ÀÁ¢µçÔ´(88-300 VDC»ò85-264 VAC)£¬²Ù×÷ζÈ-40 ~ 85 ¡ãC
PTC-101-M-LC-LV 10/100BaseT(X)ת100BaseFX¹âµçת»»Æ÷£¬¶àÄ££¬LC½ÓÍ·£¬Ë«ÈßÓàµçÔ´ÊäÈë(20-70 VDC)£¬²Ù×÷ζÈ-40 ~ 85 ¡ãC
PTC-101-S-SC-LV 10/100BaseT(X)ת100BaseFX¹âµçת»»Æ÷£¬µ¥Ä££¬SC½ÓÍ·£¬Ë«ÈßÓàµçÔ´ÊäÈë(20-70 VDC)£¬²Ù×÷ζÈ-40 ~ 85 ¡ãC
PTC-101-M-ST-LV 10/100BaseT(X)ת100BaseFX¹âµçת»»Æ÷£¬¶àÄ££¬ ST½ÓÍ·£¬Ë«ÈßÓàµçÔ´ÊäÈë(20-70 VDC)£¬²Ù×÷ζÈ-40 ~ 85 ¡ãC
PTC-101-M-SC-LV 10/100BaseT(X)ת100BaseFX¹âµçת»»Æ÷£¬¶àÄ££¬SC½ÓÍ·£¬Ë«ÈßÓàµçÔ´ÊäÈë(20-70 VDC)£¬²Ù×÷ζÈ-40 ~ 85 ¡ãC

 


¹«Ë¾¼ò½é
²úƷĿ¼
¹©Ó¦ÐÅÏ¢

¹«Ë¾Ãû³Æ£º ±±¾©À¶²©Ô¶Ñï¿Æ¼¼·¢Õ¹ÓÐÏÞ¹«Ë¾
µç »°£º 010 62632232 82483045 / Ñî֥Ȩ
ÊÖ»ú£º 13911904509
µØ Ö·£º ±±¾©Êк£µíÇøÖйشå´ó½ÖEÊÀ½ç²Æ¸»ÖÐÐÄA×ùA631
ÓÊ ±à£º 100086
Ö÷ Ò³£º http://www.lbyy2008.com

¸Ã³§ÉÌÏà¹Ø²úÆ·£º
  • MOXA UPort 1450ϵÁÐ
  •  
  • MOXA UPort 1250/1250I
  •  
  • MOXA UPort™ 1150/1150I
  •  
  • MOXA UPort 1130
  •  
  • MOXA UPort 1610-16
  •  
  • MOXA UPort 1610-8/1650-8
  •  
  • MOXA UPort 1400ϵÁÐ
  •  
  • MOXA UPort 1110 (ÐÂÆ·£¡)
  •  
  • MOXA UPort™ 2410
  •  
  • moxa UPort™ 2210
  •  
    ¸ü¶à²úÆ·...
      ¹ØÓÚÎÒÃÇ | ÁªÏµÎÒÃÇ | ¹ã¸æ·þÎñ | ±¾Õ¾¶¯Ì¬ | ÓÑÇéÁ´½Ó | ·¨ÂÉÉùÃ÷ | ·Ç·¨ºÍ²»Á¼ÐÅÏ¢¾Ù±¨  
    ¹¤¿ØÍø¿Í·þÈÈÏߣº0755-86369299
    °æȨËùÓÐ ¹¤¿ØÍø Copyright@ Gkong.com, All Rights Reserved