WinCC (TIA Portal) »ùÓÚȫеÄÖÐÑ빤³Ì×é̬¿ò¼Ü Totally Integrated Automation Portal£¨TIA ²©Í¾£©£¬¸Ã¿ò¼ÜΪÓû§ÌṩÁËÓÃÓÚÍê³ÉËùÓÐ×Ô¶¯»¯ÈÎÎñµÄͳһ¡¢¸ßЧºÍÖ±¹ÛµÄ½â¾ö·½°¸¡£
WinCC (TIA Portal) »¹ÌṩÁË´Ó»ù±¾ÐÍÃæ°åÖ±ÖÁ SCADA Ò»¸öÓõÄͳһ¹¤³Ì×é̬¡£
Óë STEP 7 (TIA Portal) ²úÆ·Ò»Æð£¬WinCC (TIA Portal) ³ÉΪÓÃÓÚ¼¯³É¶ø¸ßЧµÄ¹¤³Ì×é̬µÄ×î¼Ñ½â¾ö·½°¸¡£
µ±Ç°°æ±¾£º
SIMATIC WinCC Basic V11 SP1
SIMATIC WinCC Comfort V11 SP1
SIMATIC WinCC Advanced V11 SP1
SIMATIC WinCC Professional V11 SP1
Î÷ÃÅ×ÓWinCC¹¤³Ì×é̬Èí¼þ(TIA Portal) ÏúÊÛ¶©»õºÅ£º
6AV2100-0AA02-0AA5
SIMATIC WINCC BASIC V12 SP1 ENGINEERING-SW,FLOATING LICENSE SW AND DOCUMENTATION ON DVD, LICENSE KEY ON USB STICK, CLASS A, 6 LANGUAGES(GE,EN,IT,FR,SP,CH), EXECUTABLE UNDER WINDOWS XP (32 BIT) / WINDOWS 7 (32/64 BIT) / WINSRV 2008 R2 (64 BIT), FOR CONFIGURATION OF SIMATIC BASIC PANELS
6AV2100-0AA02-0AA7
SIMATIC WINCC BASIC V12 SP1 ENGINEERING-SW, TRIAL LICENSE, SW AND DOCUMENTATION ON DVD, CLASS A, 6 LANGUAGES(GE,EN,IT,FR,SP,CH), EXECUTABLE UNDER WINDOWS XP (32 BIT) / WINDOWS 7 (32/64 BIT)/ WINSRV 2008 R2 (64 BIT), FOR CONFIGURATION OF SIMATIC BASIC PANELS
6AV2100-0AA03-0AA5
SIMATIC WINCC BASIC V13 ENGINEERING SOFTWARE IN TIA PORTAL; FLOATING LICENSE; SOFTWARE AND DOCUMENTATION ON DVD; LICENSE KEY ON USB-STICK; CLASS A; 6 LANGUAGES: GE,EN,IT,FR,SP,CH; EXECUTABLE UNDER WINDOWS 7 (32 BIT, 64 BIT), WINDOWS 8.1 (64 BIT), WINSRV 2012 R2 (64 BIT); FOR CONFIGURATION OF SIMATIC BASIC PANELS
6AV2100-0AA03-0AA7
SIMATIC WINCC BASIC TRIAL V13, ENGINEERING SOFTWARE IN TIA PORTAL; TRIAL LICENSE; SW AND DOCUMENTATION ON DVD; CLASS A; 6 LANGUAGES: GE,EN,IT,FR,SP,CH; EXECUTABLE UNDER WINDOWS 7 (32 BIT, 64 BIT), WINDOWS 8.1 (64 BIT), WINSRV 2012 R2 (64 BIT); FOR CONFIGURATION OF SIMATIC BASIC PANELS
6AV2100-3AA02-0AE5
SIMATIC WINCC BASIC V12 SP1 UPGRADE V11 -> V12 SP1, ENGINEERING-SW,FLOATING LICENSE SW AND DOCUMENTATION ON DVD, LICENSE KEY ON USB STICK, CLASS A, 6 LANGUAGES(GE,EN,IT,FR,SP,CH), EXECUTABLE UNDER WINDOWS XP (32 BIT) / WINDOWS 7 (32/64 BIT) / WINSRV 2008 R2 (64 BIT), FOR CONFIGURATION OF SIMATIC BASIC PANELS
6AV2100-3AA03-0AE5
SIMATIC WINCC BASIC V13 UPGRADE V11..V12 -> V13 OR V11..V12 COMBO -> V13 COMBO; ENGINEERING SOFTWARE IN TIA PORTAL; FLOATING LICENSE; SOFTWARE AND DOCUMENTATION ON DVD; LICENSE KEY ON USB-STICK; CLASS A; 6 LANGUAGES: GE,EN,IT,FR,SP,CH; EXECUTABLE UNDER WINDOWS 7 (32 BIT, 64 BIT), WINDOWS 8.1 (64 BIT), WINSRV 2012 R2 (64 BIT); FOR CONFIGURATION OF SIMATIC BASIC PANELS
6AV2101-0AA02-0AA5
SIMATIC WINCC COMFORT V12 SP1 ENGINEERING-SW,FLOATING LICENSE SW AND DOCUMENTATION ON DVD, LICENSE KEY ON USB STICK CLASS A, 6 LANGUAGES(GE,EN,IT,FR,SP,CH), EXECUTABLE UNDER WINDOWS XP (32 BIT) / WINDOWS 7 (32/64 BIT) / WINSRV 2003 R2/2008 (32 BIT) / WINSRV 2008 R2 (64 BIT), FOR CONFIGURATION OF SIMATIC PANELS
6AV2101-0AA03-0AA5
SIMATIC WINCC COMFORT V13 ENGINEERING SOFTWARE IN TIA PORTAL; FLOATING LICENSE; SOFTWARE AND DOCUMENTATION ON DVD; LICENSE KEY ON USB-STICK; CLASS A; 6 LANGUAGES: GE,EN,IT,FR,SP,CH; EXECUTABLE UNDER WINDOWS 7 (32 BIT, 64 BIT), WINDOWS 8.1 (64 BIT), WINSRV 2008/2012 R2 (64 BIT); FOR CONFIGURATION OF SIMATIC PANELS
6AV2101-2AA02-0AC5
SIMATIC WINCC COMFORT POWERPACK WINCC BASIC -> WINCC COMFORT V12 (NO CHANGE OF VERSION) ENGINEERING-SW,FLOATING LICENSE SW AND DOCUMENTATION ON DVD, LICENSE KEY ON USB STICK, CLASS A; ONLY VALID FOR 6AV2100-0AA02-0AA5 OR 6AV2100-0AA02-0AH5
6AV2101-2AA03-0AC5
SIMATIC WINCC COMFORT POWERPACK WINCC BASIC -> WINCC COMFORT V13 (NO CHANGE OF VERSION) ENGINEERING SOFTWARE IN TIA PORTAL; FLOATING LICENSE; SOFTWARE AND DOCUMENTATION ON DVD; LICENSE KEY ON USB-STICK; CLASS A; ONLY VALID FOR 6AV2100-0AA03-0AA5 OR 6AV2100-0AA03-0AH5
¼¯³ÉµÄ×é̬Èí¼þ¿É½µµÍÅàѵ¡¢Î¬»¤ºÍάÐ޳ɱ¾£¬²¢Äܱ£»¤¿Í»§Í¶×Ê
ͨ¹ýÈ«¼¯³É×Ô¶¯»¯ (TIA) ½«×é̬ҪÇó½µµ½×îµÍ²¢½µµÍÊÙÃüÑ»·³É±¾
²ÉÓ÷ḻµÄ¶¯Ì¬¶ÔÏ󣬽µµÍ×é̬¹¤×÷Á¿
ʹÓÃÖÇÄܹ¤¾ß½øÐÐ×é̬£¬¼òµ¥¶øÓÖ¸ßЧ¡£
ÓÃÓÚ¶¨Òå HMI ÏîÄ¿»ù±¾½á¹¹µÄÏòµ¼
±í¸ñʽ±à¼Æ÷¼ò»¯ÏàͬÀàÐͶÔÏóµÄÉú³ÉºÍ´¦Àí£¬ÀýÈç±äÁ¿£¬Îı¾»ò¾¯±¨¡£
ͨ¹ýͼÐÎ×é̬¿ÉÒÔ¼ò»¯¸´ÔÓµÄ×é̬ÈÎÎñ£¬È綨ÒåÔ˶¯Â·¾¶»ò´´½¨»ù±¾²Ù×÷Ô±Ìáʾ¡£
È«ÇòÓõĶàÓïÑÔ×é̬×ÛºÏÐÔÖ§³Ö
ʹÓöàÖÖÓïÑÔÊäÈë×é̬Êý¾ÝµÄ¿ÉÑ¡ÊÓͼ
רÃÅÊõÓï¿ÉÓÉϵͳ¶¨Òå»òÓû§¶¨Òå
µ¼Èë/µ¼³öÓïÑÔÎı¾
Ͷ×ʰ²È«ÐÔÊÇÓÉÓÚ
´Ó WinCC flexible 2008 SP2 »ò¸ü¸Ä°æ±¾µ¼Èë×é̬
SIMATIC WinCC Basic¡¢Comfort¡¢Advanced ºÍ Professional µÈ°æ±¾ÊÇ´´ÐµĹ¤³Ì×é̬¹¤¾ß£¬ÓÃÓÚ×é̬ SIMATIC HMI ²Ù×÷Ô±Ãæ°åÒÔ¼°»ùÓÚ PC µÄ¿ÉÊÓ»¯ÏµÍ³ WinCC Runtime Advanced ºÍ WinCC Runtime Professional¡£
¸ù¾ÝÑ¡ÔñµÄ²úÆ·£¬¿É×é̬¸÷ÖÖÄ¿±êϵͳ£º
WinCC Basic
»ù±¾²Ù×÷Ãæ°å
WinCC Comfort
WinCC Basic£¬Íâ¼Ó£º
ÊæÊÊÐÍÃæ°å
ÒÆ¶¯ÐÍÃæ°å£ºÒƶ¯ÐÍÃæ°å 177£¬Òƶ¯ÐÍÃæ°å 277£¬
70 ϵÁÐÃæ°å£ºOP 73, OP 77A, OP 77B
170 ϵÁеÄÃæ°å£ºTP 177A, TP 177B, OP 177B
270 ϵÁеÄÃæ°å£ºTP 277, OP 277
¶à¹¦ÄÜÃæ°å£ºMP 177, MP 277, MP 377
WinCC Advanced
WinCC Comfort£¬Íâ¼Ó£º
´øÓÐ WinCC Runtime Advanced µÄ SIMATIC PC£º
SIMATIC Ãæ°å PC£ºIPC277D¡¢Ãæ°åʽ PC 477B¡¢IPC477C¡¢IPC477D¡¢Ãæ°åʽ PC 577B¡¢IPC577C¡¢Ãæ°åʽ PC 677B¡¢IPC677C
SIMATIC Ïäʽ PC£ºIPC227D¡¢Ïäʽ PC 427B¡¢IPC427C¡¢IPC427D¡¢Ïäʽ PC 627B¡¢IPC627C¡¢Ïäʽ PC 827B¡¢IPC827C
SIMATIC Rack PC£¨»ú¼Üʽ PC£©£º»ú¼Üʽ PC 547B¡¢IPC547C¡¢IPC547D¡¢»ú¼Üʽ PC 647B¡¢IPC647C¡¢»ú¼Üʽ PC 847B¡¢IPC847C
SIMATIC Ä£¿é»¯Ç¶Èëʽ¿ØÖÆÆ÷£ºEC31
´øÓÐ WinCC Runtime Advanced µÄ±ê×¼ PC
SINUMERIK PC£ºPCU 50.3, PCU 50.5
WinCC Professional
WinCC Advanced£¬Íâ¼Ó£º
´øÓÐ WinCC Runtime Professional µÄ SIMATIC PC£º
SIMATIC Ãæ°å PC£ºIPC477C¡¢IPC477D¡¢Ãæ°åʽ PC 577B¡¢IPC577C¡¢Ãæ°åʽ PC 677B¡¢IPC677C¡¢
SIMATIC Ïäʽ PC£ºIPC427C¡¢IPC427D¡¢Ïäʽ PC 627B¡¢IPC627C¡¢IPC827C
SIMATIC Rack PC£¨»ú¼Üʽ PC£©£º»ú¼Üʽ PC 547B¡¢IPC547C¡¢IPC547D¡¢»ú¼Üʽ PC 647B¡¢IPC647C¡¢»ú¼Üʽ PC 847B¡¢IPC847C
´øÓÐ WinCC Runtime Professional µÄ±ê×¼ PC
SIMATIC WinCC ϵÁй¤³Ì×é̬¹¤¾ßµÄ¹¦ÄÜÊÇÏ໥ÒÀÍеġ£¿ÉÓÃµÄ±à¼Æ÷Ö÷ÒªÓÉÏàÓ¦µÄ¿É×é̬Ŀ±êϵͳ¼°Æä¹¦Äܾö¶¨¡£Ò²¿ÉʹÓøü¼ÓÈ«ÃæµÄ¹¤³Ì×é̬¹¤¾ß£¨Èç WinCC Advanced£©À´×é̬ϲãÄ¿±êÉ豸£¨Èç»ù±¾ÐÍÃæ°å£©¡£
¿ÉʹÓÃÒ»¸ö¹éµµ±äÁ¿°ü (Powerpack) ´ÓСÐͰ汾Éý¼¶Îª´óÐͰ汾¡£Õâ²»ÊÊÓÃÓÚ WinCC Basic¡£
WinCC ¹¤³Ì×é̬¹¤¾ßµÄ¹¦ÄÜÒѰüº¬ SIMATIC Ãæ°å¡¢WinCC Runtime Advanced »ò WinCC Runtime Professional µÄ¿ÉÓÃÔËÐÐÑ¡ÏîµÄ×é̬֧³Ö£¬¶ø²»¹ÜËù¹ºÂòµÄ RT ÊÚȨÈçºÎ¡£µ±Ê¹ÓÃ×é̬µÄÔËÐÐÑ¡Ïîʱ£¬Ä¿±êϵͳÐèÒªµ¥¶ÀÒ»·ÝÊÚȨ¡£
¼¯³ÉÔÚ×Ô¶¯»¯ÏµÍ³ÖÐ
¼¯³Éµ½ SIMATIC Totally Integrated Automation Portal (TIA Portal) ÖÐ
ͨ¹ý¿ØÖÆÆ÷ºÍÈË»ú½çÃæÊµÏÖ¹²ÏíÊý¾Ý¹ÜÀíºÍͳһ·ûºÅ
¹¤×÷»·¾³ÖеĿØÖÆÆ÷ÓëÈË»ú½çÃæÖ®¼äʵÏÖ×î¼Ñ½»»¥
¾ßÓм¯³ÉϵͳÕï¶Ï¹¦ÄÜ
¹²ÏíʹÓÃͨÐÅÉèÖú͹ý³Ìµã¶¨Òå
ÔÚÈË»ú½çÃæÉ豸ÉÏ£¨ÀýÈ磬ÔÚ»ÃæÖУ©¶Ô±äÁ¿½øÐмò±ãÍÏ·Å
×é̬½Ó¿Ú
Ö±¹ÛµÄÓû§½çÃæ£¬²Ù×÷Ê®·Ö·½±ã
ÇåÎú¡¢¿ìËٵطÃÎÊ±à¼Æ÷ºÍÏîÄ¿Êý¾Ý
È¡¾öÓÚÒÑ×é̬Ŀ±êϵͳµÄ×é̬¹¤¾ß×ÔÊÊӦͼÐÎÓû§½çÃæ (GUI)
Óû§×Ô¶¨Òå UI ÉèÖã¬ÀýÈç²¼¾Ö¡¢¹¤¾ßÀ¸
¼¯³É´óÅúÁ¿Êý¾Ý²Ù×÷£¬¿É½øÐиßЧ×é̬
ÏîÄ¿´¦Àí
ÓëÉ豸Î޹صÄ×é̬Êý¾Ý²»ÓÃת»»£¬¼´¿ÉÔÚ²»Í¬Ä¿±êϵͳÉÏʹÓ᣽çÃæ¿É¸ù¾ÝÄ¿±êÉ豸µÄ¹¦ÄܽøÐе÷Õû¡£
ÔÚ¶àÉ豸ÏîÄ¿ÖпçÉ豸ʹÓù²Ïí×é̬Êý¾Ý£¨È籨¾¯Àà±ð¡¢Îı¾¿â£©¡£
ͨ¹ýÏòµ¼¶¨Òå HMI ÏîÄ¿µÄ»ù±¾½á¹¹£¨ÈçÏÔʾ»®·Ö¡¢²Ù×÷Ô±Ìáʾ£©
ÆÁÄ»±à¼Æ÷´øÓпÉʵÏÖ¸ßЧ¡¢¿ìËÙÆÁÄ»×é̬µÄ´óÁ¿Ñ¡¼þ
ʹÓÃÍϷʦÄÜÀ´Éú³ÉÁ´½ÓµÄͼÐζÔÏó£¬ÀýÈ磬Éú³ÉÓÃÓÚÉú³É´øÓйý³Ì½Ó¿ÚµÄÊäÈë/Êä³ö¿òµÄ±äÁ¿£¬»òÉú³É¾ßÓÐÏÔʾѡÔñ¹¦Äܵİ´Å¥
¶¨Òå»ÃæÄ£°åºÍ¹¦ÄÜ£¨Óë MS PowerPoint µÄĸ°æÏ൱£©
ʹÓÃÓû§ÓѺÃÐÍ±à¼Æ÷¿ÉÉú³É¸÷ÖÖÃæ°å£¬´øÓж¨ÒåºÃµÄº¬ÓÐͼÐζÔÏóµÄÍⲿ½çÃæ
¶Ô¹ì¼£½øÐÐͼÐÎ×é̬
×î¶à 32 ²ãµÄϵͳ
ÓÃÓÚ¶ÔÆë¡¢ÐýתºÍ¾µÏñÐýת¹¦ÄܵŤ¾ß
µ¼Èë/µ¼³ö
±äÁ¿¡¢Á´½Ó¡¢Îı¾ÁбíºÍºÍ±¨¾¯
±í¸ñ±à¼Æ÷
ÏàͬÀàÐÍ×é̬¶ÔÏóµÄ¿ì½ÝÉú³ÉºÍ´¦Àí£¬ÀýÈçÔÚ±í¸ñʽ±à¼Æ÷ÖеıäÁ¿£¬Îı¾»òÏûÏ¢
È¡¾öÓÚÊÂÏÈÒÑ×é̬ºÃµÄÊý¾ÝµÄÖÇÄÜĬÈÏÉèÖã¬ÀýÈ磬ÔÚÉú³ÉÁ¬Ðø±äÁ¿Ê±×Ô¶¯µÝÔöµØÖ·
¿É·½±ãµØ·ÃÎʶÔÏóÊôÐÔ£¬ÎÞÐè¶àÓàµÄÓû§½éÈë
¹²Ïí¶ÔÏóÊôÐÔµÄͬʱ¸ü¸Ä
»ùÓÚ¶ÔÏóµÄÊý¾Ý¹ÜÀí£¬Ê¹ÓÃÓû§ÓѺõÄËÑË÷ºÍ±à¼Ñ¡¼þ
Ö±½ÓÔÚ HMI ±äÁ¿ÉÏ×é̬±¨¾¯ºÍÈÕÖ¾£¬²»ÓÃÔÚ²»Í¬±à¼Æ÷Ö®¼äÇл»
½»²æ²Î¿¼Áбí¿ÉÖ±½Ó·ÃÎÊËùÓжÔÏó£¬ÀýÈçÓÃÓÚ¸ü¸Ä»òÑ¡Ôñ
¿ÉÔÚÕû¸öÏîÄ¿ÄÚËÑË÷¶ÔÏó
ËÑË÷/Ìæ»»Îı¾
ÏîÄ¿¹éµµ
Ñ¡ÔñÐÔÏîÄ¿¹éµµ£¬¿É´òÓ¡ÒÔÏÂÄÚÈÝ£º
Õû¸öÏîÄ¿
Ò»¸ö»ò¶à¸öÓëÏîÄ¿Ïà¹ØµÄÉ豸
±à¼Æ÷µÄÄÚÈÝ
¿â
Ô¤¶¨Òå/Óû§¶¨ÒåµÄ×é̬¶ÔÏóµÄ¿â
½«ËùÓй¤³Ì¶ÔÏó´æ´¢ÔÚ¿âÖУ¬ÀýÈ磬¿éºÍÕû¸öÏÔʾÄÚÈÝ»ò±äÁ¿£»
¿É¸ù¾Ý¿Í»§ºÍÏîÄ¿ÌØ¶¨ÒªÇ󣬴Ӽòµ¥µÄ»Ãæ¶ÔÏó¹¹½¨Ãæ°å¡£ÕâÐ©Ãæ°åµÄÐ޸ĿÉÔڿ鶨ÒåÖм¯ÖÐÍê³É¡£
¹©»õ·¶Î§ÄÚÌṩÓзḻµÄ¶¯Ì¬Í¼ÐζÔÏó
¹©»õ·¶Î§ÄÚ°üÀ¨ÊʺϹ¤ÒµÓ¦ÓõĴóС¿ÉËõ·ÅµÄͼÐÎ
¿â¶ÔÏóÔ¤ÀÀ¹¦ÄÜ
ÓïÑÔÖ§³Ö
ͨ¹ýת»»ÊÓͼÔÚ±à¼Æ÷ÖÐÉú³É¶àÓïÑÔÏîÄ¿£¨×î¶à 32 ÖÖÓïÑÔ£©
¿âÖÐÏà¹ØÓïÑÔÎı¾ºÍͼÐεÄÖÐÑë¹ÜÀí
±à¼£¬µ¼Èë/µ¼³ö·ÒëÎı¾
ÒÀÓïÑÔ¶ø¶¨µÄͼÐÎ
Visual Basic ºÍ C-Script Ö§³Ö
IntelliSense ¹¦ÄÜ£¬¿É¿ìËÙ±à³Ì·ÃÎÊÔËÐÐʱ¶ÔÏó
ÒԽű¾´úÂë¼òµ¥´´½¨¿ØÖÆË³Ðò
Ä£ÄâÆ÷ÒÔ¼° WinCC Runtime Advanced ºÍ WinCC Runtime Professional ÖÐµÄ Visual Basic Script µ÷ÊÔ
²âÊԺ͵÷ÊÔÖ§³Ö
ÔÚ¹¤³Ì PC ÉϽøÐÐ HMI ÏîÄ¿·ÂÕæ
Ö±½ÓÔÚÏàÓ¦±à¼Æ÷Öбê¼Ç²»ÍêÕû»ò²»ÕýÈ·µÄ×é̬
´Ó±àÒëÆ÷ÏûÏ¢¿ªÊ¼Ìø×ªµ½¹ÊÕÏÔÒò
ÏÖÓÐ HMI ÏîÄ¿µÄÒÆÖ²
WinCC flexible ÏîÄ¿ÖеÄÍêÕûÊý¾Ý´«Êä