¼¼ÊõÒªÇó/Specifications
|
ÒýÓñê×¼ Reference Standard
|
GB 7332(EC60384-2), CECC30401-009,DIN44112,ITT005 10101-QS
|
|
ÆøºòÀà±ð Climatic Category
|
55/100/56
|
|
¶î¶¨µçѹ Rated Voltage
|
63V¡¢100V¡¢160V¡¢250V¡¢400¡¢630V
|
|
µçÈÝÁ¿·¶Î§ Capacitance range
|
0.0010μF to 2.2μF
|
|
µçÈÝÁ¿Æ«²î Capacitance Tolerance
|
±5%(J), ±10%(K)£¬±20%(M)
|
|
×Ü×ÔÉíµç¸Ð Total Self-inductance
|
≈8nH(P=7.5), 9nH(P=10.0), 10nH(P=15.0)
*Òý³öÏß³¤¶È leads length£º¡«2mm
|
|
Ä͵çѹ Voltage proof
|
1.6UR (5S)
|
|
ËðºÄ½ÇÕýÇÐ Dissipation factor
|
²âÊÔÆµÂÊ£¨Frequency£©
|
CR ≤0.1μF
|
CR £¾0.1μ
|
|
1KHz
|
≤1.0%
|
≤1.0%
|
|
10KHz
|
≤1.5%
|
≤1.5%
|
|
1 KHz
|
≤3.0%
|
≤1.5%
|
|
¾øÔµµç×è Insulation resistance
|
UR£¾100V
|
≥30,000MΩ£¬CR≤0.33μF
≥10,000S£¬ CR£¾0.33μ (20¡æ,100V,1min)
|
|
UR≥00V
|
≥15,000MΩ£¬CR≤0.33μF
≥5,000S£¬ CR£¾0.33μ (20¡æ,10V,1min)
|
¿É¿¿ÐÔ(DIN 40040)/Reliability(DIN 40040):
ʹÓÃÌõ¼þ£ºÎ¶È(40¡æ)£¬µçѹ( 0.5×UR)
ʧЧÂÊ≤5Fit(1FIT=1×10-9ʧЧÊý/Ôª¼þ×Сʱ)
ʧ½»ÅоÝ( DIN 44122)£º¶Ì·»ò¿ªÂ·£»µçÈÝÁ¿±ä»¯(¡÷C/C±10%)£ºËðºÄ½ÇÕýÇб仯£¨¡÷tgδ >2׶ֵ£©
¾øÔµµç×裨< 0.005׶ֵ£©
Application Condition:Temperaturet£¨40¡æ ) ,Voltage ( 0.5 x UR£©
Failure Rate:≤5Fit
Failure Criteria(DIN 44122):Short or open circuit;Capacitance change ( ¡÷C/C±10%)£»
Disspation factor change ( ¡÷tgδ> 2 x initial limit) ;
Insulation resistance£¨0.005 x initial limit£©
´Ë²úÆ·¹Ø¼ü×Ö£ºÐ£ÕýµçÈÝ
»ªÔ£µçÈÝ-¸ßÆ·ÖʽðÊô»¯±¡Ä¤µçÈÝ×¨ÒµÖÆÔìÉÌ