MIE-2606PϵÁÐ1¹â5µçÍø¹ÜÐÍ×ÔÓú»·È«Ç§Õ×POE¹¤ÒµÒÔÌ«Íø½»»»»ú£¬¿ÉÌṩ4¸öPOE¹©µç¶Ë¿Ú£¬Ö§³ÖIEEE802.3af/atÒÔÌ«Íø¹©µç±ê×¼£¬²ÉÓÃÏȽøµÄ×Ô¸ÐÖªËã·¨£¬Ö»ÎªÖ§³ÖIEEE802.3af/at¹©µç±ê×¼µÄÖÕ¶ËÉ豸¹©µç£¬²»ÐèҪȥµ£ÐÄ»áËð»µË½Óбê×¼µÄPoE»ò·ÇPoEÉ豸¡£×Ô¶¯Ê¶±ð PoE µÄÐèÇó£¬Ëٶȣ¬Ë«¹¤µÈÌØÊâÍøÏßÀàÐÍ£¬Ê¹Óüòµ¥·½±ã£¬ÎÞÐèÅäÖ㬼´²å¼´ÓᣠÍø¹ÜÐÍÉè¼Æ£¬ÊµÏÖÔÚÏßʵʱ¼à¿Ø£¬ÎªÍøÂçͨÐŵݲȫÌṩÁ˸üÓÐÀûµÄ±£ÕÏ¡£×¨ÎªÒ»Ð©ÐèÒª¼ò»¯ÎÞÏß·ÃÎʵã(AP£©ºÍ»ùÓÚIPµÄÍøÂçÉãÏñÍ·µÄ°²×°µÄÉÌÒµÍøÂç¶øÉè¼Æ¡£ÕâЩԶÀëµçÔ´²å×ùµÄÉ豸ͨ³£»á¹ÒÔÚǽ±Ú¸ß´¦»òÌ컨°åÉÏ¡£PoEÏû³ýÁËΪÕâЩÉ豸ÌØÒâÁ¬½ÓµçÔ´²å×ùµÄÂé·³¡£Ê¹ÄÇЩԶÀë½»Á÷µçÔ´É豸µÄÁ¬½Ó¸üÁé»î£¬¼ò»¯²¼Ïߣ¬¿ÉÁé»îÀ©Õ¹£¬³¹µ×°ÚÍѼÒÍ¥¡¢°ì¹«ÊÒÍøÂç¶ø²»ÊܵçÁ¦Ïß²¼¾ÖÏÞÖÆ¡£´«Ë;àÀë´ï100m£¬·Ç³£ÊʺÏÎÞÏß³ÇÊС¢°²·À¼à¿ØµÈÐÐҵʹÓá£
MIE-2606PϵÁÐ1¹â5µçÍø¹ÜÐÍ×ÔÓú»·È«Ç§Õ×POE¹¤ÒµÒÔÌ«Íø½»»»»ú¿ÉÒÔ×齨һ¸ö¿ìËÙ»Ö¸´µÄ×ÔÓú»·Íø£¬×ÔÓúʱ¼äСÓÚ20ms£¬ÎªÓû§µÄÍøÂ簲ȫÌṩÓÐÁ¦µÄ±£ÕÏ¡£MIE-2606PϵÁÐ1¹â5µçÍø¹ÜÐÍ×ÔÓú»·È«Ç§Õ×POE¹¤ÒµÒÔÌ«Íø½»»»»úÖ§³Ö¶Ô¹âÏË»·Â·µÄ×Ô¶¯¼ì²âºÍµ¹»»£¬È«¸ºÔØϹÊÕϻָ´Ê±¼ä£¼20ms£¬¿É×齨Á´ÐΡ¢»·Ðεȸ÷ÖÖ¹âÏËÍøÂç¡£»ùÓÚWEBµÄÍø¹Üƽ̨Ϊ²úÆ·Ìṩ·á¸»µÄÍø¹Ü¹¦ÄÜ£¬°üÀ¨£º»ùÓڶ˿ڵÄVLAN¡¢»ùÓÚ802.1QµÄVLAN¡¢QOS¡¢IGMP Snooping¡¢RSTP¡¢¹ã²¥·ç±©ÒÖÖÆ¡¢¶Ë¿Ú¾ÛºÏ¡¢¶Ë¿Ú¾µÏñ¡¢¶Ë¿Ú״̬¹ÜÀí¡¢SNMP¡¢NTP¶ÔʱµÈ¡£
MIE-2606P ¹¦ÄÜÌØÐÔ
1. ¸ßÐÔÄܽ»»»Ð¾Æ¬£¬Âú×ã¼à¿ØÐÐÒµÌØÊâÐÔÐèÇó
2. ¶Ë¿ÚÅäÖÃÁé»î£¬¹âµçÈÎÒâ×éºÏ
3. Ö§³ÖIEEE802.3at(30W)±ê×¼£¬¼æÈÝIEEE802.3af(15.4W)µÄÊܵçÉ豸£¨PD£©
4. ÄÜ×Ô¶¯¼ì²âʶ±ð·ûºÏIEEE 802.3at¼°IEEE802.3af±ê×¼µÄÊܵçÉ豸£»ÏȽøµÄ×Ô¸ÐÖªË㷨ֻΪIEEE 802.3af/at±ê×¼µÄÖÕ¶ËÉ豸¹©µç£¬²»ÐèÈ¥µ£ÐÄ»áËð»µË½Óбê×¼µÄPOE»ò·ÇPOEÉ豸
5. Ö§³Ö¶Ë¿Ú¹©µçÓÅÏȼ¶£¬±£Ö¤ÍøÂç¹Ø¼ü½ÚµãµÄ³ÖÐø¹©µç
6. ÄÚÖÃPSE¹©µçÄ£¿éÉè¼Æ,ʹ¹©µç¸ü¼Ó±ã½Ý¡¢¼òµ¥
7. Ö§³Ö¶àÖÖÍø¹Ü·½Ê½SNMP ¡¢WEB¡¢ Telnet
8. Ö§³Ö4K·ûºÏIEEE802.1Q VLAN
9. Ö§³Ö¸ß´ï8KµÄµ¥²¥MACµØÖ·
10. Ö§³Ö»ùÓÚMACµØÖ·µÄ¶Ë¿Ú¾ÛºÏ
11. È«Ë«¹¤ºÍ°ëË«¹¤Á÷Á¿¿ØÖÆ£¨IEEE 802.3X£©Ö§³Ö×Ô¶¯µØַѧϰºÍÀÏ»¯
12. Ö§³ÖÉú³ÉÊ÷ÐÒ飨STP£©
13. ¿ìËÙÉú³ÉÊ÷ÐÒ飨RSTP£©ºÍ¶àÉú³ÉÊ÷ÐÒ飨MSTP£©
14. Ö§³ÖIEEE 802.1xµÄMAC°²È«
15. Íâ¿Ç²ÉÓÃIP30·À»¤µÈ¼¶
16. Ö§³Ö¿íÎÂ-40¡«+75¡æ
MIE-2606P ¼¼Êõ²ÎÊý
Ãû³Æ
|
¹æ¸ñ²ÎÊý
|
ÒÔÌ«Íø¿Ú
|
4¸ö10/100/1000Base-T(X)×ÔÊÊÓ¦ÒÔÌ«ÍøRJ45½Ó¿Ú£¬ÆäÖÐ1¡«4¶Ë¿ÚΪPOE¿Ú
|
¹â¿Ú
|
2¸ö1000Base-LX¹â¿Ú
|
ÒÔÌ«Íø¿Ú´«ÊäËÙÂÊ
|
1O/1OO/1000M×ÔÊÊÓ¦
|
ÒÔÌ«Íø¿Ú´«Êä¾àÀë
|
Ë«½ÊÏß:100m(²ÉÓñê×¼CAT5£¬CAT5e ÍøÂçÏßÀÂ)
|
¹â¿Ú¹¤×÷²¨³¤
|
µ¥Ä£1310nm£¬¶àÄ£850nm
|
¹â¿Ú·¢Éä¹â¹¦ÂÊ
|
µ¥Ä£-3¡«-11dB£¬¶àÄ£-8¡«-18dB
|
¹â¿Ú´«Êä¾àÀë
|
µ¥Ä£20km,¶àÄ£550m£¨³¤¾àÀëÄ£¿é¿É¶¨ÖÆ£©
|
×ÔÓú»··½Ê½
|
Ö§³Ö¶à×é×ÔÓú»·
|
Ö§³ÖÏàÇл·
|
ÈßÓ༼Êõ
|
Ö§³ÖRingÐÒé(×ÔÓúʱ¼ä<20ms),STP\RSTP(×ÔÓúʱ¼ä<10s)
|
ÍøÂç¹ÜÀí¼à¿Ø
|
Ö§³ÖTelnet, WEB¹ÜÀí·½Ê½, SNMPv1/v2 , LLDP, NTP, DHCP
|
×é²¥ÐÒé
|
Ö§³ÖIGMP Snooping, ¾²Ì¬×é²¥
|
ÍøÂç»®·Ö
|
Ö§³Ö»ùÓڶ˿ÚVLAN, IEEE-802.1Q
|
·þÎñÖÊÁ¿
|
Ö§³ÖQoS
|
´ø¿í¹ÜÀí
|
Ö§³Ö¶Ë¿Ú¾ÛºÏ, ¶Ë¿ÚÏÞËÙ, ¹ã²¥·ç±©ÒÖÖÆ, ×é²¥\δ֪µ¥²¥°üÒÖÖÆ
|
ÍøÂ簲ȫ
|
Ö§³Ö¶Ë¿ÚMACµØÖ·°ó¶¨, IP·ÃÎÊ¿ØÖÆ, IEEE802.1X, SSH, SSL
|
É豸¹ÜÀí
|
Ö§³ÖFTP/TFTPÉý¼¶,Ö§³ÖÈÕÖ¾¼Ç¼, Ö§³ÖÅäÖÃÎļþÏÂÔØÓëÉÏ´«
|
É豸ά»¤
|
Ö§³Ö¶Ë¿Ú¾µÏñ, ping¹¦ÄÜ
|
¸æ¾¯Êä³ö
|
Ö§³ÖµçÔ´ºÍ¶Ë¿Ú¸æ¾¯
|
ÌØÉ«¹¦ÄÜ
|
Ö§³ÖÁ´Â·¼ì²â(Link Check)
|
ÓÅÏȼ¶
|
ÓÅÏȼ¶¶ÓÁÐ:4
|
VLAN»®·Ö
|
VLANÊý:4K£¬VLAN ID:1¡«4094
|
×é²¥×éÊý
|
×é²¥×éÊý:256
|
´¦ÀíÀàÐÍ
|
´æ´¢×ª·¢
|
MACµØÖ·±í´óС
|
8k
|
±³°å´ø¿í
|
10Gbps
|
°üת·¢ËÙÂÊ
|
14.88Mpps
|
Á÷¿Ø
|
IEEE 802.3xÁ÷Á¿¿ØÖÆ£¬°ë/Ë«¹¤±³Ñ¹Á÷Á¿¿Ø
|
°ü»º³åÇø´óС
|
384K
|
ָʾµÆ
|
µçԴָʾ£ºPWR1¡¢PWR2£¬½Ó¿ÚµÆָʾ£ºLink¡¢RUN¡¢AlARM¡¢SPEED
|
µçÔ´
|
ÊäÈëµçѹ£ºDC48V
|
6λÂÌÉ«¶Ë×Ó½ÓÏß
|
×î´ó¹¦ºÄ£º4.84W£¬µ¥¿Ú¹©µç¹¦ÂÊ¿É´ï30W
|
Ö§³ÖË«µçÔ´ÊäÈë
|
¹¤×÷»·¾³
|
¹¤×÷ζȣº-40¡æ¡«+75¡æ
|
´¢´æζȣº-40¡æ¡«85¡æ
|
Ïà¶Ôʪ¶È£º5£¥¡«95£¥ÎÞÄý¶
|
°²×°·½Ê½
|
DIN¿¨¹ìʽ»ò±Ú¹Òʽ
|
ÍâÐγߴç
|
¿í׸ß×É53×140×119.5mm
|
·À»¤µÈ¼¶
|
IP30·À»¤µÈ¼¶£¬ÎÞ·çÉÈÉè¼Æ
|
MTBF
|
300000h
|
Öʱ£ÆÚ
|
5Äê
|
·ûºÏ±ê×¼
|
IEEE802.3£ºCSMA/CD
|
IEEE802.3i£º10Base-T
|
IEEE802.3u£º100Base-T
|
IEEE802.3ab-----1000Base-T
|
IEEE802.3z-1000Base-SXºÍ1000Base-LX
|
IEEE802.3at/IEEE802.3af
|
IEEE 802.3ad£ºÁ´Â·¾ÛºÏ
|
IEEE 802.3x£ºÈ«Ë«¹¤ÒÔÌ«ÍøÊý¾ÝÁ´Â·²ãÁ÷¿Ø
|
IEEE 802.1p£ºÁ÷Á¿ÓÅÏȼ¶
|
IEEE 802.1Q£ºVLAN
|
IEEE 802.1w£º¿ìËÙÉú³ÉÊ÷
|
IEEE 802.1X£º»ùÓڶ˿ڵÄÍøÂç·ÃÎÊ¿ØÖÆ
|
EMI
|
µç´Å¸ÉÈŶȲâÊÔ
|
EMC
|
IEC61000-4-2(ESD) ±8kV(contact),±15kV(air)
|
IEC61000-4-3(RS) 10V/m(80MHz¡«2GHz)
|
IEC61000-4-4(EFT) Power Port:±4kV;Data Port:±2kV
|
IEC61000-4-5(Surge) Power Port:±2kV/DM,±4kV/CM;Data Port:±2kV
|
IEC61000-4-6(CS) 3V(10kHz¡«150kHz);10V(150kHz¡«80MHz)
|
IEC61000-4-16(¹²Ä£´«µ¼) 30V(cont.),300V(1s)
|
MIE-2606P EMCµÈ¼¶
Ãû³Æ
|
ÒÀ¾Ý±ê×¼
|
µÈ¼¶
|
¾²µç·Åµç¿¹ÈŶÈÊÔÑé
|
GB/T 17626.2-1998
|
4¼¶
|
µç¿ìËÙ˲±äÂö³åȺ¿¹ÈŶÈÊÔÑé
|
GB/T 17626.4-199
|
4¼¶
|
ÀËÓ¿(³å»÷)¿¹ÈŶÈ
|
GB/T 17626.5-1999
|
4¼¶
|
Âö³å´Å³¡¿¹ÈŶÈÊÔÑé
|
GB/T 17626.9-1998
|
4¼¶
|
MIE-2606P °²×°»úеͼ
MIE-2606P Ñ¡ÐÍ×ÊÁÏ
²úÆ·ÐͺÅ
|
¹æ¸ñ²ÎÊý
|
MIE-2606P-GX2
|
4¸ö10/100/1000M PoEµç¿Ú£¬2¸ö1000M SFPÀ©Õ¹²Û£¬Ö§³ÖÍø¹Ü
|
MIE-2606P ¿ÉÑ¡¸½¼þ
²úÆ·ÐͺÅ
|
¹æ¸ñ˵Ã÷
|
µçÔ´ÊÊÅäÆ÷
|
ME-PWR-20-24
|
DC24VÊä³ö¿¨¹ìʽµçÔ´Ä£¿é£¬ÊäÈë85-264VAC»ò120-370VDC
|
1G SFPÄ£¿é
|
ME-S2101
|
SFP with 10M/100M/1000M£¨RJ-45£©
|
ME-S2118-S
|
SFP 1.25G/1.0625G¡¢ 850nm LC 550m
|
ME-S2123-S
|
SFP 1.25G/1.0625G¡¢ 1310nm LC 20km
|
ME-S2123-S40
|
SFP 1.25G/1.0625G¡¢ 1310nm LC 40km
|
ME-S2125-S80
|
SFP 1.25G/1.0625G ¡¢1550nm LC 80km
|
ME-S2123S-S
|
SFP 1.25G/1.0625G¡¢ 1310nm µ¥ÏËLC 20km
|
ME-S2123S-S40
|
SFP 1.25G/1.0625G¡¢ 1310nm µ¥ÏËLC 40km
|
ME-S2125S-S80
|
SFP 1.25G/1.0625G ¡¢1550nm µ¥ÏËLC 80km
|
Èç¹ûÄúÏëÁ˽â¸ü¶à¹ØÓÚMIE-2606P 2¹â4µçÍø¹ÜÐÍ×ÔÓú»·È«Ç§Õ×POE¹¤ÒµÒÔÌ«Íø½»»»»úµÄÏêϸÐÅÏ¢£¬ÇëµÇ¼ÎÒÃǵĹٷ½ÍøÕ¾£¬Í¬Ê±ÄúÒ²¿ÉÒÔÁªÏµÎÒÃǵÄÏúÊÛ¹¤³Ìʦ£¬ÎÒÃǽ«½ß³ÏΪÄú·þÎñ£¡
ÉϺ£×ܲ¿£º¡¡
µç »°£º021-67756421/2/3/4/5/6/9 ¡¡
·þÎñÈÈÏߣº400-66-12508
´« Õ棺021-67756427
ÓÊ ±à£º201615
ÓÊ Ï䣺mexontec@mexontec.com
µØ Ö·£ºÉϺ£ÊÐËɽ¸ß¿Æ¼¼Ô°Çø¾Åãþ·959ºÅºÀØ®´´ÒµÔ°±±×ù6F/4F
꿅᣼http://www.mexontec.com
ÄϾ©°ìÊ´¦:µç»°£º025-66916358
³É¶¼°ìÊ´¦:µç»°£º028-87606176
±±¾©°ìÊ´¦:µç»°£º010-62931243
ÉîÛÚ°ìÊ´¦:µç»°£º0755-26403312
Î÷°²°ìÊ´¦:µç»°£º029-88223137