C2000 E210ÊǾßÓиßÐÔ¼Û±ÈÇÒÎȶ¨¿É¿¿µÄ´®¿ÚÉ豸ǶÈëʽÁªÍøÄ£¿é£¬ËüÌṩTTL´®¿Úµ½TCP/IPÍøÂçºÍTCP/IPÍøÂçµ½TTL´®¿ÚÊý¾Ý͸Ã÷´«Ê䣬Ëü¿ÉÒÔʹÉ豸Á¢¼´¾ß±¸ÁªÈëTCP/IPÍøÂçµÄ¹¦ÄÜ¡£
C2000 E210ÏòÉÏÌṩ10MÒÔÌ«Íø½Ó¿Ú£¬ÏòÏÂÌṩ1¸ö±ê×¼TTL´®Ðпڣ¬Í¨Ñ¶²ÎÊý¿Éͨ¹ý¶àÖÖÉèÖ÷½Ê½ÉèÖá£C2000 E210¿É¹ã·ºÓ¦ÓÃÓÚPLC¿ØÖÆÓë¹ÜÀí¡¢ÃŽûÒ½ÁÆ¡¢Â¥Óî¿ØÖÆ¡¢¹¤Òµ×Ô¶¯»¯¡¢²âÁ¿ÒÇ±í¼°»·¾³¶¯Á¦¼à¿ØÏµÍ³¡¢ÐÅÏ¢¼Òµç¡¢LEDÐÅÏ¢ÏÔʾÉ豸ºÍCNC¹ÜÀíµÈ¡£
ÌØµã£º
→¾ßÓÐTCP Server¡¢TCP Client¡¢UDP¡¢ÐéÄâ´®¿Ú¡¢µã¶ÔµãÁ¬½ÓµÈÎåÖÖ²Ù×÷ģʽ£»
→Óû§»ùÓÚÍøÂçÈí¼þ£¬²»ÐèÒª×öÈκÎÐ޸ľͿÉÒÔÓëC2000 E210ͨѶ£»
→ͨ¹ý°²×°ÎÒÃÇÃâ·ÑÌṩµÄÐéÄâ´®¿ÚÈí¼þ£¬Óû§»ùÓÚ´®¿ÚµÄÈí¼þ²»ÐèÒª×öÈκÎÐ޸ľͿÉÒÔÓëC2000 E210ͨѶ£»
→¶ÔÓÚÐèÒª¿ª·¢Èí¼þµÄÓû§£¬ÎÒÃÇÃâ·ÑÌṩͨѶ¶¯Ì¬¿â¡¢ÉèÖö¯Ì¬¿â»òOCX¿Ø¼þ£»
→ͨ¹ýä¯ÀÀÆ÷¡¢ÉèÖÃÈí¼þ»òÉèÖö¯Ì¬¿â½øÐвÎÊýÉèÖã»
→Ö§³ÖDNSÓòÃû½âÎö¹¦ÄÜ£»
→µÍÏûºÄÉè¼Æ£¬ÎÞÐèÉ¢ÈÈ×°Öã»
→¿´ÃŹ·Éè¼Æ£¬Îȶ¨ÐԸߡ£
a) ±¾²úÆ·ÓÐÒÔÏÂÈýÖÖ¹¤×÷ģʽ£º
1£®×÷ΪTCP·þÎñÆ÷£¬×ª»»Æ÷ÉϵçºóÔÚÖ¸¶¨µÄTCP ¶Ë¿ÚµÈ´ýÊý¾Ý·þÎñÆ÷µÄÁ¬½ÓÇëÇó£¬Êý¾Ý·þÎñÆ÷ÔÚÐèÒªÓëת»»Æ÷ͨѶµÄʱºò£¬Ïòת»»Æ÷µÄ¼àÌý¶Ë¿ÚÇëÇó½¨Á¢TCP Á¬½Ó£¬Á¬½Ó½¨Á¢ºó£¬Êý¾Ý·þÎñÆ÷¿ÉÒÔËæÊ±Ïòת»»Æ÷·¢ËÍÊý¾Ý£¬×ª»»Æ÷Ò²¿ÉÒÔËæÊ±½«Êý¾Ý·¢Ë͵½Êý¾Ý·þÎñÆ÷£¬ÔÚÍê³ÉÖ¸¶¨µÄͨѶºó£¬Êý¾Ý·þÎñÆ÷¿ÉÒÔÖ÷¶¯ÒªÇó¶Ï¿ªÁ¬½Ó£¬·ñÔòÁ¬½ÓÒ»Ö±±£³Ö¡£
2£®×÷ΪTCP¿Í»§¶Ë£¬×ª»»Æ÷Éϵçʱ»áÖ÷¶¯Ïò·þÎñÆ÷ÇëÇóÁ¬½Ó£¬Ö±µ½TCPÁ¬½Ó½¨Á¢ÎªÖ¹£¬²¢ÇÒÁ¬½ÓÒ»µ©½¨Á¢½«Ò»Ö±±£³Ö£¬Á¬½Ó½¨Á¢ºó£¬Êý¾Ý·þÎñÆ÷¿ÉÒÔËæÊ±Ïòת»»Æ÷·¢ËÍÊý¾Ý£¬×ª»»Æ÷Ò²¿ÉÒÔËæÊ±½«Êý¾Ý·¢Ë͵½Êý¾Ý·þÎñÆ÷¡£
3£®UDP·½Ê½ÓÐÁ½ÖÖ£º
µ±C2000 ¹¤×÷ÔÚ“UDP normal”ģʽʱ£¬C2000»á»ØÓ¦ËùÓеÄIPµØÖ·ºÍ¶Ë¿Ú·¢¹ýÀ´µÄÊý¾Ý£¬²¢½«·µ»ØµÄÊý¾Ý·¢Ë͵½×îºóÒ»´Î·¢¸øËü²éѯÇëÇóµÄIPµØÖ·ºÍ¶Ë¿Ú¡£
µ±C2000 ¹¤×÷ÔÚ“UDP Appointed”ģʽʱ£¬ËüÄܽÓÊÕËùÓеÄIPµØÖ·ºÍ¶Ë¿Ú·¢¹ýÀ´µÄÊý¾Ý£¬µ«Ö»½«·µ»ØµÄÊý¾Ý·¢Ë͸øÖ¸¶¨µÄIPµØÖ·ºÍ¶Ë¿Ú¡£
b) Ó¦ÓÃÈí¼þ¿ÉʹÓÃÈýÖÖ·½Ê½Óëת»»Æ÷ͨѶ£º
1£®Í¨¹ý±¾¹«Ë¾¿ª·¢µÄÐéÄâ´®¿Ú¹ÜÀí³ÌÐò£¬½«ÍøÂçÊý¾ÝÖØ¶¨Ïòµ½ÐéÄâ´®¿Ú£¬È»ºó´ÓÐéÄâ´®¿Ú¶ÁÈ¡Êý¾Ý£»
2£®Óñ¾¹«Ë¾¿ª·¢µÄ¿Ø¼þEDSockServer.ocx(»ò¶¯Ì¬¿âEDSockServer.dll)£»
3£®Ê¹ÓÃSocket½øÐÐͨѶ¡£
1.2 ¼¼Êõ²ÎÊý
ϵͳ
|
CPU
|
32-bit ARM
|
RAM
|
64KB
|
Flash
|
256KB
|
LAN
|
ËÙÂÊ
|
10M/100Mbps
|
½Ó¿Ú
|
RJ45
|
´®¿Ú
|
TTL
|
RXD£¬TXD£¬RTS£¬CTS£¬GND
|
´®¿ÚͨÐŲÎÊý
|
ЧÑé
|
None£¬Even£¬Odd£¬MARK£¬SPACE
|
Êý¾Ýλ
|
6¡¢7¡¢8
|
ֹͣλ
|
1¡¢2
|
Á÷Á¿¿ØÖÆ
|
RTS/CTS£¬XON/XOFF£¬None
|
ËÙÂÊ
|
300bps~115200bps
|
Èí¼þÌØµã
|
ÐÒé
|
ARP£¬IP£¬ICMP£¬TCP£¬UDP£¬DHCP£¬HTTP£¬DNS
|
²Ù×÷ģʽ
|
TCP Server¡¢TCP Client£¬UDP£¬ÐéÄâ´®¿Ú¡¢µã¶ÔµãÁ¬½Ó
|
ÉèÖÃ
|
C2000ÉèÖóÌÐò¡¢Webä¯ÀÀÆ÷¡¢ÉèÖö¯Ì¬¿â¡¢´®¿ÚÉèÖ㨿ÉÑ¡£©
|
ÌṩÈí¼þ
|
ÐéÄâ´®¿ÚÈí¼þ¡¢C2000ÉèÖóÌÐò¡¢´®¿Úµ÷ÊÔ¹¤¾ß¡¢ÍøÂçÉèÖóÌÐò¡¢EDSockServer.OCX¿Ø¼þ¡¢EDSockServer.DLL¶¯Ì¬¿â¡¢ÉèÖö¯Ì¬¿âÒÔ¼°VB¡¢VC¡¢BC¡¢DelphiµÄʾÀý´úÂë
|
Çý¶¯Ö§³Ö
|
Windows 98/ME/2000/XP/2003/Vista/Windows 7 32λ
|
µçÔ´ÐèÇó
|
µçÔ´¹æ¸ñ
|
5VDC£¬±5%
|
µçÁ÷
|
×î´óµçÁ÷СÓÚ180mA
|
»·¾³
|
²Ù×÷ζÈ
|
-25¡æ~85¡æ
|
´¢´æÎ¶È
|
-60¡æ~125¡æ
|
ʪ¶È
|
5~95%RH£¬²»Äý¶
|
³ß´ç
|
Òý½Å¼ä¾à
|
2.54mm
|
Ä£¿éÓÐÁ½ÅŲåÕëÒý½ÅJ1ºÍJ2£¬ÓÃÓÚÓëÓû§°åÁª½Ó£¬¸ÃÁ½ÅÅÒý½Å·Ö±ðÓÐ9¸öºÍ8¸ö²åÕ룬Æä²åÕ붨ÒåÈçÏ£º
J1¶¨Òå
J1(Òý½ÅÐòºÅ)
|
¹¦ÄÜÃû³Æ
|
±¸×¢£¨Ê¹ÓÃÒªµã¼°×¢ÒâÊÂÏ
|
1
|
TXD(´®¿ÚÐźŷ¢ËͶË)
|
Ä£¿éÄÚ²¿ÉÏÀ£¬½¨Òé½Ó4.7K ÉÏÀµç×è¡£
|
2
|
RXD(´®¿ÚÐźŽÓÊÕ¶Ë)
|
Ä£¿éÄÚ²¿ÉÏÀ£¬½¨Òé½Ó4.7K ÉÏÀµç×è¡£
|
3
|
CTS(´®¿Ú)
|
Ä£¿éÄÚ²¿ÉÏÀ£¬½¨Òé½Ó4.7K ÉÏÀµç×è¡£
|
4
|
RTS(´®¿Ú)
|
Ä£¿éÄÚ²¿ÉÏÀ£¬½¨Òé½Ó4.7K ÉÏÀµç×è¡£
|
5
|
RESET(ÊÖ¶¯¸´Î»ÊäÈë¶Ë)
|
µÍµçƽģ¿é¸´Î»£¬²»Ê¹ÓÃʱ¿ÉÐü¿Õ»ò½ÓµçÔ´£»Ê¹ÓÃʱ¿ÉÓëÓû§ÏµÍ³¸´Î»¶ËÏàÁ¬(×¢ÒâÓÐЧ¸´Î»µçƽΪ“0”»¹ÊÇΪ“1”)
|
6
|
SETUP(»Ö¸´³ö³§ÉèÖÃ)
|
Ä£¿éÄÚ²¿ÉÏÀ£¬½«´ËÒý½Å½ÓµØ£¬Ä£¿é°´³ö³§ÉèÖù¤×÷£¬²»Ê¹ÓÃʱ¿ÉÐü¿Õ¡£
|
7
|
PROTECT£¨ÉèÖÃÐÅϢд±£»¤£©
|
Ä£¿éÄÚ²¿ÉÏÀ£¬½«¸ÃÒý½ÅÐü¿Õ»ò½ÓVCC ʱ£¬ÉèÖòÎÊý½«²»»á±»¸Äд£»½ÓµØÊ±·½¿É¸Äд²ÎÊý¡£
|
8
|
VCC£¨µçÔ´Õý¼«£©
|
½Ó+5V µçÔ´£¬½¨Òé¿¿½ü¸ÃÒý½Å¼Ó0.1uF µçÈݺÍ100uF µÄµç½âµçÈÝ£¨µçÔ´·¶Î§4.5V~5.5V£©¡£
|
9
|
GND£¨µçÔ´¸º¼«£©
|
½ÓµØ
|
J2¶¨Òå
J2(Òý½ÅÐòºÅ)
|
¹¦ÄÜÃû³Æ
|
±¸×¢£¨Ê¹ÓÃÒªµã¼°×¢ÒâÊÂÏ
|
1
|
MODE
|
ÒÔÌ«ÍøÈ«Ë«¹¤¡¢°ëË«¹¤Ö¸Ê¾µÆ£¬È«Ë«¹¤µãÁÁ£¬¸ßµçƽÇý¶¯LED¡£
|
2
|
SPEED
|
ÒÔÌ«10M/100MָʾµÆ£¬100MµãÁÁ£¬¸ßµçƽÇý¶¯LED¡£
|
3
|
TPIN+(ERX+)
|
ÍøÂçÊý¾Ý²î·Ö½ÓÊÕÕý¶Ë£¬Ê¹Ó÷½·¨²Î¿¼ÏÂÃæµÄʾÀýͼ¡£
|
4
|
TPIN-(ERX-)
|
ÍøÂçÊý¾Ý²î·Ö½ÓÊÕ¸º¶Ë£¬Ê¹Ó÷½·¨²Î¿¼ÏÂÃæµÄʾÀýͼ¡£
|
5
|
LD(ETX-)
|
ÍøÂçÊý¾Ý²î·Ö·¢Ë͸º¶Ë£¬Ê¹Ó÷½·¨²Î¿¼ÏÂÃæµÄʾÀýͼ¡£
|
6
|
HD(ETX+)
|
ÍøÂçÊý¾Ý²î·Ö·¢ËÍÕý¶Ë£¬Ê¹Ó÷½·¨²Î¿¼ÏÂÃæµÄʾÀýͼ¡£
|
7
|
E_COM
|
ÍøÂç·¢ËͶ˵IJο¼Ðźš£
|
8
|
LINK
|
ÒÔÌ«ÍøÁ¬½ÓָʾµÆ£¬Á¬½Ó״̬µãÁÁ£¬¸ßµçƽÇý¶¯LED¡£
|
¸Å Êö
|
C2000 E210ÊǾßÓиßÐÔ¼Û±ÈÇÒÎȶ¨¿É¿¿µÄ´®¿ÚÉ豸ǶÈëʽÁªÍøÄ£¿é£¬ËüÌṩTTL´®¿Úµ½TCP/IPÍøÂçºÍTCP/IPÍøÂçµ½TTL´®¿ÚµÄÊý¾Ý͸Ã÷´«Ê䣬Ëü¿ÉÒÔʹÉ豸Á¢¼´¾ß±¸ÁªÈëTCP/IPÍøÂçµÄ¹¦ÄÜ¡£
C2000 E210ÏòÉÏÌṩ10/100MÒÔÌ«Íø½Ó¿Ú£¬ÏòÏÂÌṩ1¸ö±ê×¼TTL´®Ðпڣ¬Í¨Ñ¶²ÎÊý¿Éͨ¹ý¶àÖÖ·½Ê½ÉèÖᣠC2000 E210¿É¹ã·ºÓ¦ÓÃÓÚPLC¿ØÖÆÓë¹ÜÀí¡¢ ÃŽûÒ½ÁÆ¡¢ Â¥Óî×Ô¿Ø¡¢ ¹¤Òµ×Ô¶¯»¯¡¢ ²âÁ¿ÒÇ±í¼°»·¾³¶¯Á¦¼à¿ØÏµÍ³¡¢ ÐÅÏ¢¼Òµç¡¢ LEDÐÅÏ¢ÏÔʾÉ豸ºÍCNC¹ÜÀíµÈ¡£
|
|
¡¡Ó¦ ÓÃ
|
→PLC¿ØÖÆÓë¹ÜÀí
→ÃŽûÒ½ÁÆ
→Â¥Óî×Ô¿Ø
→¹¤Òµ×Ô¶¯»¯
→²âÁ¿ÒÇ±í¼°»·¾³¶¯Á¦¼à¿ØÏµÍ³
→ÐÅÏ¢¼Òµç
→LEDÐÅÏ¢ÏÔʾÉ豸
→CNC¹ÜÀí
|
|
¡¡¼¼Êõ²ÎÊý
|
ϵͳ
|
CPU
|
32-bit ARM
|
RAM
|
64KB
|
Flash
|
256KB
|
LAN
|
ËÙÂÊ
|
10M/100Mbps
|
½Ó¿Ú
|
RJ45
|
´®¿Ú
|
TTL
|
RXD£¬TXD£¬RTS£¬CTS£¬GND
|
´®¿ÚͨÐŲÎÊý
|
ЧÑé
|
None£¬Even£¬Odd£¬MARK£¬SPACE
|
Êý¾Ýλ
|
6¡¢7¡¢8
|
ֹͣλ
|
1¡¢2
|
Á÷Á¿¿ØÖÆ
|
RTS/CTS£¬XON/XOFF£¬None
|
ËÙÂÊ
|
300bps~115200bps
|
Èí¼þÌØµã
|
ÐÒé
|
ARP£¬IP£¬ICMP£¬TCP£¬UDP£¬DHCP£¬HTTP£¬DNS
|
²Ù×÷ģʽ
|
TCP Server¡¢TCP Client£¬UDP£¬ÐéÄâ´®¿Ú¡¢µã¶ÔµãÁ¬½Ó
|
ÉèÖÃ
|
C2000ÉèÖóÌÐò¡¢Webä¯ÀÀÆ÷¡¢ÉèÖö¯Ì¬¿â¡¢´®¿ÚÉèÖ㨿ÉÑ¡£©
|
ÌṩÈí¼þ
|
ÐéÄâ´®¿ÚÈí¼þ¡¢C2000ÉèÖóÌÐò¡¢´®¿Úµ÷ÊÔ¹¤¾ß¡¢ÍøÂçÉèÖóÌÐò¡¢EDSockServer.OCX¿Ø¼þ¡¢EDSockServer.DLL¶¯Ì¬¿â¡¢ÉèÖö¯Ì¬¿âÒÔ¼°VB¡¢VC¡¢BC¡¢DelphiµÄʾÀý´úÂë
|
Çý¶¯Ö§³Ö
|
Windows 98/ME/2000/XP/2003/Vista/Windows 7 32λ
|
µçÔ´ÐèÇó
|
µçÔ´¹æ¸ñ
|
5VDC£¬±5%
|
µçÁ÷
|
×î´óµçÁ÷СÓÚ180mA
|
»·¾³
|
²Ù×÷ζÈ
|
-25¡æ~85¡æ
|
´¢´æÎ¶È
|
-60¡æ~125¡æ
|
ʪ¶È
|
5~95%RH£¬²»Äý¶
|
³ß´ç
|
Òý½Å¼ä¾à
|
2.54mm
|
|
|