MIER-5226½»»»»úÊǶþ²ãÍø¹ÜÐ͹¤ÒµÒÔÌ«Íø½»»»»ú,רΪÂú×ã¶ÔEMCÐÔÄÜÒªÇóÑϸñµÄ¹¤ÒµÍ¨ÐÅϵͳÐèÇóÉè¼Æ£¬½»»»»úÊÇÓÉ24¸ö10/100Base–TX»ò100Base-FX¶Ë¿ÚÒÔ¼°2¸öǧÕ×¶Ë¿Ú×é³É¡£½»»»»úÖ§³ÖMR-Ring×ÔÓú»·£¬ÊʺÏÓÃ×÷ÖÐÐĶ˽»»»»ú£¬×î´óµÄÌØµãÊÇÖ§³Ö¶à×é×ÔÓú»·Íø£¬¿ÉÓÉÓû§×ÔÐÐÉ趨×ÔÓú»·µÄ»·Â·¶Ë¿Ú£¬¶ø2¸öǧÕ׿ڿÉÒÔ½«¶ą̀MIER-5226×é³ÉǧÕ××ÔÓú»·£¬±£Ö¤¶à¸öÖÐÐĽ»»»»úÖ®¼äµÄǧÕ×Á´Â·°²È«¡£
MIER-5226Ö§³Ö¶àÖÖÍøÂç¹ÜÀí·½Ê½£¬È磺SNMP£¬Webä¯ÀÀÆ÷£¬TelnetºÍRS232¿ØÖÆÌ¨¹ÜÀí¡£Íø¹ÜÄÚÈݰüÀ¨£º¶Ë¿ÚÅäÖá¢ËùÓн»»»»ú¶þ²ã¹¦ÄÜ¡¢RSTP¡¢MR-Ring¡¢·ÃÎÊ¿ØÖÆ¡¢Ô¶³Ì¼à¿Ø¡¢¶Ë¿Úͳ¼Æ¡¢ÍøÂçÕï¶ÏµÈ¡£MIER-5226µÄ¹¤×÷ζȷ¶Î§¿ÉÒÔ´ïµ½-40¡æÖÁ75¡æ£¬¿ÉÒԷdz£ÇáËɵØÊÊÓ¦»·¾³±È½Ï¶ñÁӵĹ¤Òµ³¡Ëù¡£
MIER-5226 ¼¼Êõ²ÎÊý
Ãû³Æ
|
¹æ¸ñ²ÎÊý
|
ÒÔÌ«Íø¿Ú
|
0¡«24¸ö10/100Base-T(X)×ÔÊÊÓ¦ÒÔÌ«ÍøRJ45½Ó¿Ú
|
¹â¿Ú
|
24¡«0¸ö100Base-FX¹â¿Ú£¬µ¥/¶àÄ£SC/ST/FC½Ó¿Ú¿ÉÑ¡
|
ǧÕ×¶Ë¿Ú
|
2¸ö1000¶Ë¿Ú£¬Ö§³Ö¹â¿Ú»òµç¿Ú
|
ÒÔÌ«Íø¿Ú´«ÊäËÙÂÊ
|
1O/1OOM×ÔÊÊÓ¦
|
ÒÔÌ«Íø¿Ú´«Êä¾àÀë
|
Ë«½ÊÏß:100m(²ÉÓñê×¼CAT5£¬CAT5e ÍøÂçÏßÀÂ)
|
¹â¿Ú¹¤×÷²¨³¤
|
°ÙÕ×£ºµ¥Ä£1310nm£¬¶àÄ£1310nm£»Ç§Õ×£ºµ¥Ä£1310nm£¬¶àÄ£850nm
|
¹â¿Ú´«Êä¾àÀë
|
°ÙÕ×£ºµ¥Ä£20km,¶àÄ£2km£»Ç§Õ×£ºµ¥Ä£20km,¶àÄ£550m£¨³¤¾àÀëÄ£¿é¿É¶¨ÖÆ£©
|
×ÔÓú»··½Ê½
|
Ö§³Ö¶à×é×ÔÓú»·
|
Ö§³ÖÏàÇл·
|
ÈßÓ༼Êõ
|
Ö§³ÖRingÐÒé(×ÔÓúʱ¼ä<20ms),STP\RSTP(×ÔÓúʱ¼ä<10s)
|
ÍøÂç¹ÜÀí¼à¿Ø
|
Ö§³ÖTelnet, WEB¹ÜÀí·½Ê½, SNMPv1/v2 , LLDP, NTP, DHCP
|
×é²¥ÐÒé
|
Ö§³ÖIGMP Snooping, ¾²Ì¬×é²¥
|
ÍøÂç»®·Ö
|
Ö§³Ö»ùÓÚ¶Ë¿ÚVLAN, IEEE-802.1Q
|
·þÎñÖÊÁ¿
|
Ö§³ÖQoS
|
´ø¿í¹ÜÀí
|
Ö§³Ö¶Ë¿Ú¾ÛºÏ, ¶Ë¿ÚÏÞËÙ, ¹ã²¥·ç±©ÒÖÖÆ, ×é²¥\δ֪µ¥²¥°üÒÖÖÆ
|
ÍøÂ簲ȫ
|
Ö§³Ö¶Ë¿ÚMACµØÖ·°ó¶¨, IP·ÃÎÊ¿ØÖÆ, IEEE802.1X, SSH, SSL
|
É豸¹ÜÀí
|
Ö§³ÖFTP/TFTPÉý¼¶,Ö§³ÖÈÕÖ¾¼Ç¼, Ö§³ÖÅäÖÃÎļþÏÂÔØÓëÉÏ´«
|
É豸ά»¤
|
Ö§³Ö¶Ë¿Ú¾µÏñ, ping¹¦ÄÜ
|
¸æ¾¯Êä³ö
|
Ö§³ÖµçÔ´ºÍ¶Ë¿Ú¸æ¾¯
|
ÌØÉ«¹¦ÄÜ
|
Ö§³ÖÁ´Â·¼ì²â(Link Check)
|
ÓÅÏȼ¶
|
ÓÅÏȼ¶¶ÓÁÐ:4
|
VLAN»®·Ö
|
VLANÊý:4K£¬VLAN ID:1¡«4094
|
×é²¥×éÊý
|
×é²¥×éÊý:256
|
´¦ÀíÀàÐÍ
|
´æ´¢×ª·¢
|
MACµØÖ·±í´óС
|
8k
|
±³°å´ø¿í
|
8.8Gbps
|
Á÷¿Ø
|
IEEE 802.3xÁ÷Á¿¿ØÖÆ£¬°ë/Ë«¹¤±³Ñ¹Á÷Á¿¿Ø
|
ָʾµÆ
|
µçԴָʾ£¬½Ó¿ÚµÆÖ¸Ê¾
|
µçÔ´
|
ÊäÈëµçѹ£ºAC/DC85¡«265V
|
6λÂÌÉ«¶Ë×Ó½ÓÏß
|
¹¤×÷»·¾³
|
¹¤×÷ζȣº-40¡æ¡«+75¡æ
|
´¢´æÎ¶ȣº-40¡æ¡«85¡æ
|
Ïà¶Ôʪ¶È£º5£¥¡«95£¥ÎÞÄý¶
|
°²×°·½Ê½
|
1U»ú¼Üʽ°²×°
|
ÍâÐγߴç
|
¿í׸ß×É485.8×44×280mm
|
·À»¤µÈ¼¶
|
IP30·À»¤µÈ¼¶£¬ÎÞ·çÉÈÉè¼Æ
|
MTBF
|
350000h
|
Öʱ£ÆÚ
|
5Äê
|
·ûºÏ±ê×¼
|
IEEE802.3£ºCSMA/CD
|
IEEE802.3i£º10Base-T
|
IEEE802.3u£º100Base-T
|
IEEE802.3z:1000Base-LX
|
IEEE 802.3ad£ºÁ´Â·¾ÛºÏ
|
IEEE 802.3x£ºÈ«Ë«¹¤ÒÔÌ«ÍøÊý¾ÝÁ´Â·²ãÁ÷¿Ø
|
IEEE 802.1p£ºÁ÷Á¿ÓÅÏȼ¶
|
IEEE 802.1Q£ºVLAN
|
IEEE 802.1w£º¿ìËÙÉú³ÉÊ÷
|
IEEE 802.1X£º»ùÓڶ˿ڵÄÍøÂç·ÃÎÊ¿ØÖÆ
|
EMI
|
µç´Å¸ÉÈŶȲâÊÔ
|
EMC
|
IEC61000-4-2(ESD) ±8kV(contact),±15kV(air)
|
IEC61000-4-3(RS) 10V/m(80MHz¡«2GHz)
|
IEC61000-4-4(EFT) Power Port:±4kV;Data Port:±2kV
|
IEC61000-4-5(Surge) Power Port:±2kV/DM,±4kV/CM;Data Port:±2kV
|
IEC61000-4-6(CS) 3V(10kHz¡«150kHz);10V(150kHz¡«80MHz)
|
IEC61000-4-16(¹²Ä£´«µ¼) 30V(cont.),300V(1s)
|
MIER-5226 EMCµÈ¼¶
Ãû³Æ
|
ÒÀ¾Ý±ê×¼
|
µÈ¼¶
|
¾²µç·Åµç¿¹ÈŶÈÊÔÑé
|
GB/T 17626.2-1998
|
4¼¶
|
µç¿ìËÙ˲±äÂö³åȺ¿¹ÈŶÈÊÔÑé
|
GB/T 17626.4-199
|
4¼¶
|
ÀËÓ¿(³å»÷)¿¹ÈŶÈ
|
GB/T 17626.5-1999
|
4¼¶
|
Âö³å´Å³¡¿¹ÈŶÈÊÔÑé
|
GB/T 17626.9-1998
|
4¼¶
|
MIER-5226 °²×°³ß´ç

MIER-5226 ¶©»õÐÅÏ¢
²úÆ·ÐͺÅ
|
¹æ¸ñ˵Ã÷
|
MIER-5226
|
24¸ö10/100Mµç¿Ú£¬Ö§³ÖÍø¹Ü
|
MIER-5226-GX2
|
24¸ö10/100Mµç¿Ú£¬2¸ö1000Mµç¿Ú»ò2¸ö1000M SFPÀ©Õ¹²Û£¬Ö§³ÖÍø¹Ü
|
MIER-5226MC4
|
20¸ö10/100Mµç¿Ú£¬4¸ö100M¶àÄ£SC/ST/FC¹â¿Ú£¬0-2km£¬Ö§³ÖÍø¹Ü
|
MIER-5226SC4
|
20¸ö10/100Mµç¿Ú£¬4¸ö100Mµ¥Ä£SC/ST/FC¹â¿Ú£¬0-20km£¬Ö§³ÖÍø¹Ü
|
MIER-5226MC4-GX2
|
20¸ö10/100Mµç¿Ú£¬8¸ö100M¶àÄ£SC/ST/FC¹â¿Ú£¬0-2km£¬2¸ö1000Mµç¿Ú»ò2¸ö1000M SFPÀ©Õ¹²Û£¬Ö§³ÖÍø¹Ü
|
MIER-5226SC4-GX2
|
20¸ö10/100Mµç¿Ú£¬8¸ö100Mµ¥Ä£SC/ST/FC¹â¿Ú£¬0-20km£¬2¸ö1000Mµç¿Ú»ò2¸ö1000M SFPÀ©Õ¹²Û£¬Ö§³ÖÍø¹Ü£¬
|
MIER-5226MC8
|
16¸ö10/100Mµç¿Ú£¬8¸ö100M¶àÄ£SC/ST/FC¹â¿Ú£¬1310nm£¬0-2km£¬Ö§³ÖÍø¹Ü
|
MIER-5226SC8
|
16¸ö10/100Mµç¿Ú£¬8¸ö100Mµ¥Ä£SC/ST/FC¹â¿Ú£¬1310nm£¬0-20km£¬Ö§³ÖÍø¹Ü
|
MIER-5226MC8-GX2
|
16¸ö10/100Mµç¿Ú£¬8¸ö100M¶àÄ£SC/ST/FC¹â¿Ú£¬1310nm£¬0-2km£¬2¸ö1000Mµç¿Ú»ò2¸ö1000M SFPÀ©Õ¹²Û£¬Ö§³ÖÍø¹Ü
|
MIER-5226SC8-GX2
|
16¸ö10/100Mµç¿Ú£¬8¸ö100Mµ¥Ä£SC/ST/FC¹â¿Ú£¬1310nm£¬0-20km£¬2¸ö1000Mµç¿Ú»ò2¸ö1000M SFPÀ©Õ¹²Û£¬Ö§³ÖÍø¹Ü
|
MIER-5226MC16
|
8¸ö10/100Mµç¿Ú£¬16¸ö100M¶àÄ£SC/ST/FC¹â¿Ú£¬2¸ö1000Mµç¿Ú»ò2¸ö1000M SFPÀ©Õ¹²Û£¬Ö§³ÖÍø¹Ü
|
MIER-5226SC16
|
8¸ö10/100Mµç¿Ú£¬16¸ö100Mµ¥Ä£SC/ST/FC¹â¿Ú£¬2¸ö1000Mµç¿Ú»ò2¸ö1000M SFPÀ©Õ¹²Û£¬Ö§³ÖÍø¹Ü
|
MIER-5226MC16-GX2
|
8¸ö10/100Mµç¿Ú£¬16¸ö100M¶àÄ£SC/ST/FC¹â¿Ú£¬1310nm£¬0-2km£¬2¸ö1000Mµç¿Ú»ò2¸ö1000M SFPÀ©Õ¹²Û£¬Ö§³ÖÍø¹Ü
|
MIER-5226SC16-GX2
|
8¸ö10/100Mµç¿Ú£¬16¸ö100Mµ¥Ä£SC/ST/FC¹â¿Ú£¬1310nm£¬0-20km£¬2¸ö1000Mµç¿Ú»ò2¸ö1000M SFPÀ©Õ¹²Û£¬Ö§³ÖÍø¹Ü
|
MIER-5226MC24
|
24¸ö100M¶àÄ£SC/ST/FC¹â¿Ú+2¸ö1000Mµç¿Ú»ò2¸ö1000M SFPÀ©Õ¹²Û£¬Ö§³ÖÍø¹Ü
|
MIER-5226SC24
|
24¸ö100Mµ¥Ä£SC/ST/FC¹â¿Ú+2¸ö1000Mµç¿Ú»ò2¸ö1000M SFPÀ©Õ¹²Û£¬Ö§³ÖÍø¹Ü
|
MIER-5226MC24-GX2
|
24¸ö100M¶àÄ£SC/ST/FC¹â¿Ú£¬1310nm£¬0-2km£¬2¸ö1000Mµç¿Ú»ò2¸ö1000M SFPÀ©Õ¹²Û£¬Ö§³ÖÍø¹Ü
|
MIER-5226SC24-GX2
|
24¸ö100Mµ¥Ä£SC/ST/FC¹â¿Ú£¬1310nm£¬0-20km£¬2¸ö1000Mµç¿Ú»ò2¸ö1000M SFPÀ©Õ¹²Û£¬Ö§³ÖÍø¹Ü
|
v ¿ÉÑ¡¸½¼þ
²úÆ·ÐͺÅ
|
¹æ¸ñ˵Ã÷
|
1G SFPÄ£¿é
|
ME-S2101
|
SFP with 10M/100M/1000M£¨RJ-45£©
|
ME-S2118-S
|
SFP 1.25G/1.0625G¡¢ 850nm LC 550m
|
ME-S2123-S
|
SFP 1.25G/1.0625G¡¢ 1310nm LC 20km
|
ME-S2123-S40
|
SFP 1.25G/1.0625G¡¢ 1310nm LC 40km
|
ME-S2125-S80
|
SFP 1.25G/1.0625G ¡¢1550nm LC 80km
|
ME-S2123S-S
|
SFP 1.25G/1.0625G¡¢ 1310nm µ¥ÏËLC 20km
|
ME-S2123S-S40
|
SFP 1.25G/1.0625G¡¢ 1310nm µ¥ÏËLC 40km
|
ME-S2125S-S80
|
SFP 1.25G/1.0625G ¡¢1550nm µ¥ÏËLC 80km
|
Èç¹ûÄúÏëÁ˽â¸ü¶à¹ØÓÚMIER-5226»ú¼ÜÊ½Íø¹ÜÐÍǧÕ×¹¤ÒµÒÔÌ«Íø½»»»»úÏêϸÐÅÏ¢£¬ÇëµÇ¼ÎÒÃǵĹٷ½ÍøÕ¾£¬Í¬Ê±ÄúÒ²¿ÉÒÔÁªÏµÎÒÃǵÄÏúÊÛ¹¤³Ìʦ£¬ÎÒÃǽ«½ß³ÏΪÄú·þÎñ£¡
ÉϺ£×ܲ¿£º¡¡
µç »°£º021-67756421/2/3/4/5/6/9 ¡¡
·þÎñÈÈÏߣº400-66-12508
´« Õæ£º021-67756427
ÓÊ ±à£º201615
ÓÊ Ï䣺mexontec@mexontec.com
µØ Ö·£ºÉϺ£ÊÐËɽ¸ß¿Æ¼¼Ô°Çø¾Åãþ·959ºÅºÀØ®´´ÒµÔ°±±×ù6F/4F
꿅᣼http://www.mexontec.com
ÄϾ©°ìÊ´¦:µç»°£º025-66916358
³É¶¼°ìÊ´¦:µç»°£º028-87606176
±±¾©°ìÊ´¦:µç»°£º010-62931243
ÉîÛÚ°ìÊ´¦:µç»°£º0755-26403312
Î÷°²°ìÊ´¦:µç»°£º029-88223137