Ê×Ò³ - ÐÂÎÅ - ÕÐƸ - ÏÂÔØ - ²úÆ· - ³§ÉÌ - ·½°¸ - ÎÄÕª - Çó¹º - Õ¹ÀÀ
Ãâ·Ñ×¢²á µÇ¼ | ¹ã¸æ·þÎñ | ¿Í·þÖÐÐÄ
Öлª¹¤¿ØÍø ¡ú ¹¤¿Ø²úÆ· ¡ú MIE-2105P¿¨¹ìʽ·ÇÍø¹ÜÐ͹¤ÒµÒÔÌ«Íø½»»»»ú
²úÆ·Ãû³Æ£º MIE-2105P¿¨¹ìʽ·ÇÍø¹ÜÐ͹¤ÒµÒÔÌ«Íø½»»»»ú
ÐÍ ºÅ£º MIE-2105P
¼Û ¸ñ£º 0.00
Æ· ÅÆ£º
 
Êղش˲úÆ·     ²é¿´ÊÕ²Ø

 

    MIE-2105PϵÁÐ5¿Ú¿¨¹ìʽ·ÇÍø¹ÜÐÍȫǧÕ×POE¹¤ÒµÒÔÌ«Íø½»»»»ú£¬¿ÉÌṩ1¸öǧÕ×SFPÀ©Õ¹²Û£¬4¸öǧÕ×POE¹©µç¶Ë¿Ú£¬Ö§³ÖIEEE802.3af/atÒÔÌ«Íø¹©µç±ê×¼£¬Ö§³ÖIEEE802.3af/at¹©µç±ê×¼µÄÖÕ¶ËÉ豸¹©µç£¬²»ÐèҪȥµ£ÐÄ»áËð»µË½Óбê×¼µÄPoE»ò·ÇPoEÉ豸¡£×Ô¶¯Ê¶±ð PoE µÄÐèÇó£¬Ëٶȣ¬Ë«¹¤µÈÌØÊâÍøÏßÀàÐÍ£¬Ê¹Óüòµ¥·½±ã£¬ÎÞÐèÅäÖ㬼´²å¼´Óá£

 

    MIE-2105P       ¹¦ÄÜÌØÐÔ

  • 4¸öǧÕ×PoE ¶Ë¿Ú
  • 1¸öǧÕ×SPF²å²Û
  • RJ-45¶Ë¿ÚÖ§³Ö¼«ÐÔ×Ô¶¯·­
  • Ö§³ÖMACµØÖ·×Ôѧϰ¹¦ÄÜ£¬×Ô¶¯¸üй¦ÄÜ
  • Ö§³ÖÈ«Ë«¹¤ºÍ°ëË«¹¤×Ô¶¯Ð­ÉÌ·½Ê½
  • Ö§³Ö¿íÎÂ-40¡«+75¡æ
  • IP30·À»¤¼¶±ð

 

 MIE-2105P     ¼¼Êõ²ÎÊý

Ãû³Æ

¹æ¸ñ²ÎÊý

ÒÔÌ«Íø¿Ú

4¸ö10/100/1000Base-T(X)×ÔÊÊÓ¦ÒÔÌ«ÍøRJ45½Ó¿Ú£¬Ö§³ÖPOE¹©µç

SFP¶Ë¿Ú

1¸ö1000 SFPÀ©Õ¹²Û

ÒÔÌ«Íø¿Ú´«ÊäËÙÂÊ

1O/1OO/1000M×ÔÊÊÓ¦

ÒÔÌ«Íø¿Ú´«Êä¾àÀë

Ë«½ÊÏß:100m(²ÉÓñê×¼CAT5£¬CAT5e ÍøÂçÏßÀÂ)

¹â¿Ú¹¤×÷²¨³¤

µ¥Ä£1310nm£¬¶àÄ£850nm

¹â¿Ú·¢Éä¹â¹¦ÂÊ

µ¥Ä£-3¡«-11dB£¬¶àÄ£-8¡«-18dB

¹â¿Ú´«Êä¾àÀë

µ¥Ä£20km,¶àÄ£550m£¨³¤¾àÀëÄ£¿é¿É¶¨ÖÆ£©

MACµØÖ·±í´óС

8k

±³°å´ø¿í

10Gbps

°üת·¢ËÙÂÊ

14.88Mpps

ָʾµÆ

µçԴָʾ£¬½Ó¿ÚµÆָʾ

µçÔ´

ÊäÈëµçѹ£ºDC48V

6λÂÌÉ«¶Ë×Ó½ÓÏß

µ¥¿Ú¹©µç¹¦ÂÊ¿É´ï30W

¹¤×÷»·¾³

¹¤×÷ζȣº-40¡æ¡«+75¡æ

´¢´æζȣº-40¡æ¡«85¡æ

Ïà¶Ôʪ¶È£º5£¥¡«95£¥ÎÞÄý¶

°²×°·½Ê½

DIN¿¨¹ìʽ»ò±Ú¹Òʽ 

ÍâÐγߴç

¿í׸ß×É53×140×119.5mm

·À»¤µÈ¼¶

IP30·À»¤µÈ¼¶£¬ÎÞ·çÉÈÉè¼Æ

MTBF

300000h

Öʱ£ÆÚ

5Äê

·ûºÏ±ê×¼

IEEE802.3£ºCSMA/CD

IEEE802.3i£º10Base-T

IEEE802.3u£º100Base-T

IEEE802.3ab-----1000Base-T

IEEE802.3z-1000Base-SXºÍ1000Base-LX

IEEE802.3at/IEEE802.3af

EMI

µç´Å¸ÉÈŶȲâÊÔ

EMC

IEC61000-4-2(ESD) ±8kV(contact),±15kV(air)

IEC61000-4-3(RS) 10V/m(80MHz¡«2GHz)

IEC61000-4-4(EFT) Power Port:±4kV;Data Port:±2kV

IEC61000-4-5(Surge) Power Port:±2kV/DM,±4kV/CM;Data Port:±2kV

IEC61000-4-6(CS) 3V(10kHz¡«150kHz);10V(150kHz¡«80MHz)

IEC61000-4-16(¹²Ä£´«µ¼) 30V(cont.),300V(1s)

 

MIE-2105P      °²×°»úеͼ

MIE-2105P      Ñ¡ÐÍ×ÊÁÏ

 

²úÆ·ÐͺÅ

¹æ¸ñ²ÎÊý

MIE-2105P

4¸ö10/100/1000M PoEµç¿Ú£¬1¸ö1000M SFPÀ©Õ¹²Û

 

¿ÉÑ¡ÅäÖÃ

Ãû³Æ

¹æ¸ñ˵Ã÷

 1G SFPÄ£¿é

ME-S2101

SFP with 10M/100M/1000M£¨RJ-45£©

ME-S2118-S

SFP 1.25G/1.0625G¡¢ 850nm LC 550m

ME-S2123-S

SFP 1.25G/1.0625G¡¢ 1310nm LC 20km

ME-S2123-S40

SFP 1.25G/1.0625G¡¢ 1310nm LC 40km

ME-S2125-S80

SFP 1.25G/1.0625G ¡¢1550nm LC 80km

ME-S2123S-S

SFP 1.25G/1.0625G¡¢ 1310nm µ¥ÏËLC 20km

ME-S2123S-S40

SFP 1.25G/1.0625G¡¢ 1310nm µ¥ÏËLC 40km

ME-S2125S-S80

SFP 1.25G/1.0625G ¡¢1550nm µ¥ÏËLC 80km

 

Èç¹ûÄúÏëÁ˽â¸ü¶à¹ØÓÚMIE-2105P 5¿Ú¿¨¹ìʽ·ÇÍø¹ÜÐÍȫǧÕ×POE¹¤ÒµÒÔÌ«Íø½»»»»úµÄÏêϸÐÅÏ¢£¬ÇëµÇ¼ÎÒÃǵĹٷ½ÍøÕ¾£¬Í¬Ê±ÄúÒ²¿ÉÒÔÁªÏµÎÒÃǵÄÏúÊÛ¹¤³Ìʦ£¬ÎÒÃǽ«½ß³ÏΪÄú·þÎñ£¡

ÉϺ£×ܲ¿£º¡¡
µç »°£º021-67756421/2/3/4/5/6/9 ¡¡

·þÎñÈÈÏߣº400-66-12508
´« Õ棺021-67756427

ÓÊ ±à£º201615
ÓÊ Ï䣺mexontec@mexontec.com

µØ Ö·£ºÉϺ£ÊÐËɽ­¸ß¿Æ¼¼Ô°Çø¾Åãþ·959ºÅºÀØ®´´ÒµÔ°±±×ù6F/4F 

꿅᣼http://www.mexontec.com

ÄϾ©°ìÊ´¦:µç»°£º025-66916358

³É¶¼°ìÊ´¦:µç»°£º028-87606176

±±¾©°ìÊ´¦:µç»°£º010-62931243

ÉîÛÚ°ìÊ´¦:µç»°£º0755-26403312

Î÷°²°ìÊ´¦:µç»°£º029-88223137

 

 


¹«Ë¾¼ò½é
²úƷĿ¼
¹©Ó¦ÐÅÏ¢

¹«Ë¾Ãû³Æ£º ÉϺ£Õ×ԽͨѶ¼¼ÊõÓÐÏÞ¹«Ë¾
µç »°£º 86 400-661-2508 / ÀîС½ã
´« Õ棺 021-67756427
µØ Ö·£º ÉϺ£ÊÐËɽ­Çø¾ÅͤÕò¾Åãþ·701ºÅÐÂÑÅ¿Æ´´Ô°7ºÅÂ¥5Â¥A¡¢B×ù
ÓÊ ±à£º 201615
Ö÷ Ò³£º http://www.mexontec.com

¸Ã³§ÉÌÏà¹Ø²úÆ·£º
  • Cronet CC-7412-VPX 3UÈý²ãǧÕ×VPX¾ü¹¤½»»»Ä£¿é
  •  
  • MIE-5210 2¹â6µç×ÔÓú»·¹¤ÒµÒÔÌ«Íø¹âÏ˽»»»»ú
  •  
  • Cronet EP-2805 ¹¤ÒµEPON¹âÍøÂçµ¥Ôª£¨ONU£©
  •  
  • MIE-2412MPȫǧÕ×PoE¹¤ÒµÒÔÌ«Íø½»»»»ú
  •  
  • Cronet CC-SDN-4952 100GºËÐÄSDN½»»»»ú
  •  
  • ME-M4200-R RS232/485×ÔÓú»·´®¿Ú¹â¶Ë»ú
  •  
  • MIES-5814 8GE+4G M12/IP67 Èý²ãȫǧÕ×¹¤ÒµÒÔÌ«Íø½»»»»ú
  •  
  • MIER-2024 24GE+4GSFP»ú¼ÜʽȫǧÕ×·ÇÍø¹Ü¹¤Òµ½»»»»ú
  •  
  • MexonÕ×Ô½ Cronet CC-7414 8GE+4GSFP Èý²ã¾ü¹¤ÒÔÌ«Íø½»»»»ú
  •  
  • ME-10G ¹âÏËÊÕ·¢Æ÷
  •  
    ¸ü¶à²úÆ·...
      ¹ØÓÚÎÒÃÇ | ÁªÏµÎÒÃÇ | ¹ã¸æ·þÎñ | ±¾Õ¾¶¯Ì¬ | ÓÑÇéÁ´½Ó | ·¨ÂÉÉùÃ÷ | ·Ç·¨ºÍ²»Á¼ÐÅÏ¢¾Ù±¨  
    ¹¤¿ØÍø¿Í·þÈÈÏߣº0755-86369299
    °æȨËùÓÐ ¹¤¿ØÍø Copyright@ Gkong.com, All Rights Reserved