Î÷ÃÅ×ÓPLCÄ£¿éCPU319-3PN/DP Î÷ÃÅ×ÓPLCÄ£¿éCPU319-3PN/DP´úÀíÉÌ Î÷ÃÅ×ÓPLCÄ£¿éCPU319-3PN/DPÄÄÀïÓÐÏúÊÛ Î÷ÃÅ×ÓPLCÄ£¿éCPU319-3PN/DPÔ×°ÕýÆ· Î÷ÃÅ×ÓPLCÄ£¿éCPU319-3PN/DP¿ØÖÆÆ÷ Î÷ÃÅ×ÓPLCÄ£¿éCPU319-3PN/DPÖ÷»úÄ£¿é Î÷ÃÅ×ÓPLCÄ£¿éÖйúÒ»¼¶´úÀíÉÌ
6ES7318-3EL01-0AB0
SIMATIC S7-300 CPU 1516-3 PN/DP, ÖÐÑë´¦ÀíÆ÷ mit 2MB ¹¤×÷´æ´¢Æ÷, 1. SS MPI/DP 12MBit/s, 2. SS DP-Master/´ÓÕ¾, 3. SS ÒÔÌ«Íø PROFINET, mit 2 Port ½»»»»ú, ΢ÐÍ´æ´¢¿¨ ÐèÒª
CPU 319-3 PN/DPÊÇ×î¿ìËÙµÄS7-300 CPU,¾ßÓдóÈÝÁ¿³ÌÐò´æ´¢Æ÷.³ýÁËÓÃÓÚ¼¯ÖÐʽI/OÍ⣬»¹¿ÉÓÃÓÚ·Ö²¼Ê½×Ô¶¯»¯½á¹¹ÖС£ÀýÈ磬ÓÃÓÚÉú²úÏßÉϵļ¯ÖпØÖÆÆ÷»ò¾ßÓиßËÙ´¦ÀíµÄ»ú´²¿ØÖÆÆ÷¡£
Æä³ÌÐò¿ò¼ÜÌØ±ðÊÊÓÃÓÚʹÓÃSIMATIC¹¤³Ì¹¤¾ß£¬ÀýÈ磺
ÓÃSCL±à³Ì
Óà S7-GRAPH ½øÐÐ˳Ðò¿ØÖƱà³Ì
Òò´Ë£¬¸ÃCPUÌØ±ðÊÊÓÃÓÚͨ¹ýÈí¼þʵÏֵļ¼Êõ¹¦ÄÜÈÎÎñ£¬ÀýÈ磺
ÓÃEasy Motion ControlʵÏÖÔ˶¯¿ØÖÆ
ÓÃSTEP 7¿é»ò±ê×¼£¯Ä£¿é»¯PID¿ØÖÆÊµÊ±Èí¼þ½â¾ö±Õ»·¿ØÖÆÈÎÎñ
ͨ¹ýʹÓà SIMATIC S7-PDIAG ¼ÓÇ¿¹ý³ÌÕï¶ÏÄÜÁ¦¡£
ͨ¹ýCPUÄÚÖõÄͨѶÉ豸£¬ÎÞÐèÆäËü×é¼þ¼´¿ÉʵÏÖÍøÂç×Ô¶¯»¯½â¾ö·½°¸£®
Design
CPU 319-3 PN/DP ×°ÅäÓУº
ͨ¹ý¸½¼ÓµÄERTEC 400 ASICʵÏÖ¶à´¦ÀíÆ÷ϵͳ£¬Âú×ãPROFINETͨѶ
¼«¸ßµÄ´¦ÀíÐÔÄܺÍͨѶÐÔÄÜ
2 MB RAM(¿É´æ´¢Ô¼ 680 K ÌõÖ¸Áî)£»
ͨ¹ýÀ©Õ¹RAMÖ´ÐÐÓû§³ÌÐò£¬¿ÉÒÔÏÔÖøÌá¸ßÓû§³ÌÐòµÄ¿Õ¼ä¡£×÷Ϊ³ÌÐò×°ÔØ´æ´¢Æ÷µÄ΢ÐÍ´æ´¢¿¨£¨×î´óΪ 8 MB£©Ò²ÔÊÐí½«¿ÉÒÔÏîÄ¿£¨°üÀ¨·ûºÅºÍ×¢ÊÍ£©±£´æÔÚ CPU ÖС£×°ÔØ´æ´¢Æ÷»¹¿ÉÓÃÓÚÊý¾Ý¹éµµºÍÅä·½¹ÜÀí¡£
Áé»îµÄÀ©Õ¹ÄÜÁ¦;
¶à´ï 32 ¸öÄ£¿é£¬£¨4ÅŽṹ£©
MPI/DP ×éºÏ½Ó¿Ú£»
µÚ1¸öÄÚÖà DP ½Ó¿Ú¿ÉÒÔ×î¶àͬʱ½¨Á¢ 32 ¸öÓë S7-300/400 »òÓë PG¡¢PC¡¢OP µÄÁ¬½Ó¡£ÔÚÕâЩÁ¬½ÓÖУ¬Ê¼ÖÕ·Ö±ðΪ PG ºÍ OP ¸÷±£ÁôÒ»¸öÁ¬½Ó¡£
MPI ¿ÉÒÔͨ¹ý“È«¾ÖÊý¾ÝͨѶ”Óë×î¶à32¸öCPU×齨¼òµ¥µÄÍøÂç¡£
¸Ã½Ó¿Ú¿É´ÓMPI½Ó¿ÚÖØÐÂÉèÖÃΪDP½Ó¿Ú¡£
PROFIBUS DP ½Ó¿Ú:
È«ÃæÖ§³Ö PROFIBUS DP V1 ±ê×¼¡£Õ⽫Ôö¼Ó DP V1 ±ê×¼´ÓÕ¾ÔÚÕï¶ÏºÍ²ÎÊý¸³ÖµÄÜÁ¦µÄ·¶Î§¡£
DP ½Ó¿Ú£»
µÚ2¸öÄÚÖà DP ½Ó¿Ú¿ÉÒÔ×î¶àͬʱ½¨Á¢ 32 ¸öÓë S7-300/400 »òÓë PG¡¢PC¡¢OP µÄÁ¬½Ó¡£ÔÚÕâЩÁ¬½ÓÖУ¬Ê¼ÖÕ·Ö±ðΪ PG ºÍ OP ¸÷±£ÁôÒ»¸öÁ¬½Ó¡£
DP½Ó¿Ú¿É×÷ΪDPÖ÷Õ¾»òDP´ÓվʹÓá£ÔڸýӿÚÉÏ£¬PROFIBUS DP´ÓÕ¾¿ÉÔÚµÈʱģʽÏÂÔËÐУ®È«ÃæÖ§³Ö PROFIBUS DP V1 ±ê×¼¡£Õ⽫Ôö¼Ó DP V1 ±ê×¼´ÓÕ¾ÔÚÕï¶ÏºÍ²ÎÊý¸³ÖµÄÜÁ¦µÄ·¶Î§¡£
ÒÔÌ«Íø½Ó¿Ú£»
CPU 319-3 PN/DP µÄµÚ 3 ¸ö¼¯³É½Ó¿ÚÊÇÒ»¸ö»ùÓÚÒÔÌ«Íø TCP/IP µÄ PROFINET ½Ó¿Ú£¬´øÓÐË«¶Ë¿Ú½»»»»ú¡£ËüÖ§³ÖÏÂÁÐÐÒ飺
S7ͨѶÓÃÓÚÔÚSIMATIC¿ØÖÆÆ÷¼ä½øÐÐÊý¾ÝͨѶ
PG/OP ͨѶ£¬ÓÃÓÚͨ¹ý STEP 7 ½øÐбà³Ì¡¢µ÷ÊÔºÍÕï¶Ï
ÓëHMIºÍSCADAÁ¬½ÓµÄPG/OPͨѶ
ÔÚPROFINETÉÏʵÏÖ¿ª·ÅµÄTCP/IP¡¢UDPºÍISO-on-TCP (RFC1006)ͨѶ
SIMATIC NET OPC-ServerÓÃÓÚÓëÆäËü¿ØÖÆÆ÷ÒÔ¼°CPU×Ô´øµÄI/OÉ豸½øÐÐͨѶ
SIMATIC S7-200 PLC
S7-200 PLCÊdz¬Ð¡ÐÍ»¯µÄPLC£¬ËüÊÊÓÃÓÚ¸÷Ðи÷Òµ£¬¸÷ÖÖ³¡ºÏÖеÄ×Ô¶¯¼ì²â¡¢¼à²â¼°¿ØÖƵȡ£S7-200 PLCµÄÇ¿´ó¹¦ÄÜʹÆäÎÞÂÛµ¥»úÔËÐУ¬»òÁ¬³ÉÍøÂç¶¼ÄÜʵÏÖ¸´ÔӵĿØÖƹ¦ÄÜ¡£
S7-200PLC¿ÉÌṩ4¸ö²»Í¬µÄ»ù±¾ÐͺÅÓë8ÖÖCPU¿É¹©Ñ¡ÔñʹÓá£
2£®SIMATIC S7-300 PLC
S7-300ÊÇÄ£¿é»¯Ð¡ÐÍPLCϵͳ£¬ÄÜÂú×ãÖеÈÐÔÄÜÒªÇóµÄÓ¦Ó᣸÷ÖÖµ¥¶ÀµÄÄ£¿éÖ®¼ä¿É½øÐй㷺×éºÏ¹¹³É²»Í¬ÒªÇóµÄϵͳ¡£ÓëS7-200 PLC±È½Ï£¬S7-300 PLC²ÉÓÃÄ£¿é»¯½á¹¹£¬¾ß±¸¸ßËÙ£¨0.6~0.1μs£©µÄÖ¸ÁîÔËËãËÙ¶È£»Óø¡µãÊýÔËËã±È½ÏÓÐЧµØÊµÏÖÁ˸üΪ¸´ÔÓµÄËãÊõÔËË㣻һ¸ö´ø±ê×¼Óû§½Ó¿ÚµÄÈí¼þ¹¤¾ß·½±ãÓû§¸øËùÓÐÄ£¿é½øÐвÎÊý¸³Öµ£»·½±ãµÄÈË»ú½çÃæ·þÎñÒѾ¼¯³ÉÔÚS7-300²Ù×÷ϵͳÄÚ£¬ÈË»ú¶Ô»°µÄ±à³ÌÒªÇó´ó´ó¼õÉÙ¡£SIMATICÈË»ú½çÃæ£¨HMI£©´ÓS7-300ÖÐÈ¡µÃÊý¾Ý£¬S7-300°´Óû§Ö¸¶¨µÄË¢ÐÂËÙ¶È´«ËÍÕâЩÊý¾Ý¡£S7-300²Ù×÷ϵͳ×Ô¶¯µØ´¦ÀíÊý¾ÝµÄ´«ËÍ£»CPUµÄÖÇÄÜ»¯µÄÕï¶ÏϵͳÁ¬Ðø¼à¿ØÏµÍ³µÄ¹¦ÄÜÊÇ·ñÕý³£¡¢¼Ç¼´íÎóºÍÌØÊâϵͳʼþ£¨ÀýÈ磺³¬Ê±£¬Ä£¿é¸ü»»£¬µÈµÈ£©£»¶à¼¶¿ÚÁî±£»¤¿ÉÒÔʹÓû§¸ß¶È¡¢ÓÐЧµØ±£»¤Æä¼¼Êõ»úÃÜ£¬·Àֹδ¾ÔÊÐíµÄ¸´ÖƺÍÐ޸ģ»S7-300 PLCÉèÓвÙ×÷·½Ê½Ñ¡Ôñ¿ª¹Ø£¬²Ù×÷·½Ê½Ñ¡Ôñ¿ª¹ØÏñÔ¿³×Ò»Ñù¿ÉÒ԰γö£¬µ±Ô¿³×°Î³öʱ£¬¾Í²»Äܸıä²Ù×÷·½Ê½£¬ÕâÑù¾Í¿É·ÀÖ¹·Ç·¨É¾³ý»ò¸ÄдÓû§³ÌÐò¡£¾ß±¸Ç¿´óµÄͨÐŹ¦ÄÜ£¬S7-300 PLC¿Éͨ¹ý±à³ÌÈí¼þStep 7µÄÓû§½çÃæÌṩͨÐÅ×é̬¹¦ÄÜ£¬ÕâʹµÃ×é̬·Ç³£ÈÝÒס¢¼òµ¥¡£S7-300 PLC¾ßÓжàÖÖ²»Í¬µÄͨÐŽӿڣ¬²¢Í¨¹ý¶àÖÖͨÐÅ´¦ÀíÆ÷À´Á¬½ÓAS-I×ÜÏ߽ӿں͹¤ÒµÒÔÌ«Íø×ÜÏßϵͳ£»´®ÐÐͨÐÅ´¦ÀíÆ÷ÓÃÀ´Á¬½Óµãµ½µãµÄͨÐÅϵͳ£»¶àµã½Ó¿Ú£¨MPI£©¼¯³ÉÔÚCPUÖУ¬ÓÃÓÚͬʱÁ¬½Ó±à³ÌÆ÷¡¢PC»ú¡¢ÈË»ú½çÃæÏµÍ³¼°ÆäËûSIMATIC S7/M7/C7µÈ×Ô¶¯»¯¿ØÖÆÏµÍ³¡£
3£® SIMATIC S7-400 PLC
S7-400 PLCÊÇÓÃÓÚÖС¢¸ßµµÐÔÄÜ·¶Î§µÄ¿É±à³ÌÐò¿ØÖÆÆ÷¡£
S7-400 PLC²ÉÓÃÄ£¿é»¯ÎÞ·çÉȵÄÉè¼Æ£¬¿É¿¿ÄÍÓã¬Í¬Ê±¿ÉÒÔÑ¡ÓöàÖÖ¼¶±ð£¨¹¦ÄÜÖð²½Éý¼¶£©µÄCPU£¬²¢ÅäÓжàÖÖͨÓù¦ÄܵÄÄ£°å£¬ÕâʹÓû§Äܸù¾ÝÐèÒª×éºÏ³É²»Í¬µÄרÓÃϵͳ¡£µ±¿ØÖÆÏµÍ³¹æÄ£À©´ó»òÉý¼¶Ê±£¬Ö»ÒªÊʵ±µØÔö¼ÓһЩģ°å£¬±ãÄÜʹϵͳÉý¼¶ºÍ³ä·ÖÂú×ãÐèÒª¡£
4£® ¹¤ÒµÍ¨Ñ¶ÍøÂç
Í¨Ñ¶ÍøÂçÊÇ×Ô¶¯»¯ÏµÍ³µÄÖ§Öù£¬Î÷ÃÅ×ÓµÄÈ«¼¯³É×Ô¶¯»¯ÍøÂçÆ½Ì¨ÌṩÁË´Ó¿ØÖƼ¶Ò»Ö±µ½ÏÖ³¡¼¶µÄÒ»ÖÂÐÔͨѶ£¬“SIMATIC NET”ÊÇÈ«²¿ÍøÂçϵÁвúÆ·µÄ×ܳƣ¬ËûÃÇÄÜÔÚ¹¤³§µÄ²»Í¬²¿ÃÅ£¬ÔÚ²»Í¬µÄ×Ô¶¯»¯Õ¾ÒÔ¼°Í¨¹ý²»Í¬µÄ¼¶½»»»Êý¾Ý£¬Óбê×¼µÄ½Ó¿Ú²¢ÇÒÏ໥֮¼äÍêÈ«¼æÈÝ¡£
5£® ÈË»ú½çÃæ£¨HMI£©Ó²¼þ
HMIÓ²¼þÅäºÏPLCʹÓã¬ÎªÓû§ÌṩÊý¾Ý¡¢Í¼ÐκÍʼþÏÔʾ£¬Ö÷ÒªÓÐÎı¾²Ù×÷Ãæ°åTD200£¨¿ÉÏÔʾÖÐÎÄ£©£¬OP3£¬OP7£¬OP17µÈ£»Í¼ÐÎ/Îı¾²Ù×÷Ãæ°åOP27£¬OP37µÈ£¬´¥ÃþÆÁ²Ù×÷Ãæ°åTP7£¬TP27/37£¬TP170A/BµÈ£»SIMATICÃæ°åÐÍPC670µÈ¡£¸öÈ˼ÆËã»ú£¨PC£©Ò²¿ÉÒÔ×÷ΪHMIÓ²¼þʹÓá£HMIÓ²¼þÐèÒª¾¹ýÈí¼þ£¨ÈçProTool£©×é̬²ÅÄÜÅäºÏPLCʹÓá£
6£® SIMATIC S7¹¤ÒµÈí¼þ
Î÷ÃÅ×ӵĹ¤ÒµÈí¼þ·ÖΪÈý¸ö²»Í¬µÄÖÖÀࣺ
£¨1£©±à³ÌºÍ¹¤³Ì¹¤¾ß ±à³ÌºÍ¹¤³Ì¹¤¾ß°üÀ¨ËùÓлùÓÚPLC»òPCÓÃÓÚ±à³Ì¡¢×é̬¡¢Ä£ÄâºÍά»¤µÈ¿ØÖÆËùÐèµÄ¹¤¾ß¡£STEP 7±ê×¼Èí¼þ°üSIMATIC S7ÊÇÓÃÓÚS7-300/400£¬C7 PLCºÍSIMATIC WinAC»ùÓÚPC¿ØÖƲúÆ·µÄ×é̬±à³ÌºÍά»¤µÄÏîÄ¿¹ÜÀí¹¤¾ß£¬STEP 7-Micro/WINÊÇÔÚWindowsƽ̨ÉÏÔËÐеÄS7-200ϵÁÐPLCµÄ±à³Ì¡¢ÔÚÏß·ÂÕæÈí¼þ¡£
£¨2£©»ùÓÚPCµÄ¿ØÖÆÈí¼þ »ùÓÚPCµÄ¿ØÖÆÏµÍ³WinACÔÊÐíʹÓøöÈ˼ÆËã»ú×÷Ϊ¿É±à³ÌÐò¿ØÖÆÆ÷£¨PLC£©ÔËÐÐÓû§µÄ³ÌÐò£¬ÔËÐÐÔÚ°²×°ÁËWindows NT4.0²Ù×÷ϵͳµÄSIMATIC¹¤¿Ø»ú»òÆäËüÈκÎÉÌÓûú¡£WinACÌṩÁ½ÖÖPLC£¬Ò»ÖÖÊÇÈí¼þPLC£¬ÔÚÓû§¼ÆËã»úÉÏ×÷ΪÊÓ´°ÈÎÎñÔËÐС£ÁíÒ»ÖÖÊDzå²ÛPLC£¨ÔÚÓû§¼ÆËã»úÉϰ²×°Ò»¸öPC¿¨£©£¬Ëü¾ßÓÐÓ²¼þPLCµÄÈ«²¿¹¦ÄÜ¡£WinACÓëSIMATIC S7ϵÁд¦ÀíÆ÷ÍêÈ«¼æÈÝ£¬Æä±à³Ì²ÉÓÃͳһµÄSIMATIC±à³Ì¹¤¾ß£¨ÈçSTEP 7£©£¬±àÖÆµÄ³ÌÐò¼È¿ÉÔËÐÐÔÚWinACÉÏ£¬Ò²¿ÉÔËÐÐÔÚS7ϵÁд¦ÀíÆ÷ÉÏ¡£
£¨3£©ÈË»ú½çÃæÈí¼þ ÈË»ú½çÃæÈí¼þΪÓû§×Ô¶¯»¯ÏîÄ¿ÌṩÈË»ú½çÃæ£¨HMI£©»òSCADAϵͳ£¬Ö§³Ö´ó·¶Î§µÄƽ̨¡£ÈË»ú½çÃæÈí¼þÓÐÁ½ÖÖ£¬Ò»ÖÖÊÇÓ¦ÓÃÓÚ»úÆ÷¼¶µÄProTool£¬ÁíÒ»ÖÖÊÇÓ¦ÓÃÓÚ¼à¿Ø¼¶µÄWinCC¡£
ProToolÊÊÓÃÓڴ󲿷ÖHMIÓ²¼þµÄ×é̬£¬´Ó²Ù×÷Ô±Ãæ°åµ½±ê×¼PC¶¼¿ÉÒÔÓü¯³ÉÔÚSTEP 7ÖеÄProToolÓÐЧµØÍê³É×é̬¡£ProTool/liteÓÃÓÚÎı¾ÏÔʾµÄ×é̬£¬È磺OP3£¬OP7£¬OP17£¬TD17µÈ¡£ProTool/ProÓÃÓÚ×é̬±ê×¼PCºÍËùÓÐÎ÷ÃÅ×ÓHMI²úÆ·£¬ProTool/Pro²»Ö»ÊÇ×é̬Èí¼þ£¬ÆäÔËÐаæÒ²ÓÃÓÚWindowsƽ̨µÄ¼à¿ØÏµÍ³¡£
WinCCÊÇÒ»¸öÕæÕý¿ª·ÅµÄ£¬ÃæÏò¼à¿ØÓëÊý¾Ý²É¼¯µÄSCADA£¨Supervisory Control and Data Acquisition£©Èí¼þ£¬¿ÉÔÚÈκαê×¼PCÉÏÔËÐС£WinCC²Ù×÷¼òµ¥£¬ÏµÍ³¿É¿¿ÐԸߣ¬ÓëSTEP 7¹¦Äܼ¯³É£¬¿ÉÖ±½Ó½øÈëPLCµÄÓ²¼þ¹ÊÕÏϵͳ£¬½ÚÊ¡ÏîÄ¿¿ª·¢Ê±¼ä¡£ËüµÄÉè¼ÆÊʺÏÓڹ㷺µÄÓ¦Ó㬿ÉÒÔÁ¬½Óµ½ÒÑ´æÔÚµÄ×Ô¶¯»¯»·¾³ÖУ¬ÓдóÁ¿µÄͨÐŽӿںÍÈ«ÃæµÄ¹ý³ÌÐÅÏ¢ºÍÊý¾Ý´¦ÀíÄÜÁ¦£¬Æä×îеÄWinCC5.0Ö§³ÖÔڰ칫ÊÒͨ¹ýIEä¯ÀÀÆ÷¶¯Ì¬¼à¿ØÉú²ú¹ý³Ì¡£
Overview
½« SIMATIC S7-400 Á¬½Óµ½¹¤ÒµÒÔÌ«Íø
¶àÐÒéÔËÐУ¬ÓÃÓÚ ISO¡¢TCP/IP¡¢UDP Óë PROFINET IO ÐÒé
¿Éµ÷½ÚµÄ Keep Alive ¹¦ÄÜ
Á½¸ö¶ÀÁ¢µÄ½Ó¿Ú£¨¼¯³ÉµÄÍøÂç·ÖÀ룩£º
ǧÕ×ÒÔÌ«Íø½Ó¿Ú£¬´øÓÐ RJ45 ¶Ë¿Ú£¬10/100/1000 Mbit/s ȫ˫¹¤/°ëË«¹¤£¬¾ßÓÐ×Ô¶¯Õì²â¹¦ÄÜ
PROFINET ½Ó¿Ú£¬´øÓÐËĸö RJ45 ¶Ë¿Ú£¬10/100 Mbit/s ȫ˫¹¤/°ëË«¹¤£¬Í¨¹ý 4 ¶Ë¿Ú½»»»»úÖ´ÐÐ×Ô¶¯¸Ð²âºÍ×Ô¶¯½»²æ¹¦ÄÜ
ͨ¹ýÁ½¸ö½Ó¿Ú½øÐÐͨѶ·þÎñ
¿ª·ÅʽͨѶ£¨ISO¡¢TCP/IP ºÍ UDP£©£¬Ê¹Óà UDP ¶àµã´«ËÍ£¬°üÀ¨Á½¸ö½Ó¿ÚÖ®¼äµÄ·ÓÉ
±à³ÌÆ÷/OPͨѶ£º
ͨ¹ý S7 ·ÓɵĽ»²æÍøÂç
S7 ͨѶ£¨¿Í»§¶Ë¡¢·þÎñÆ÷¡¢¶à·¸´Óã©£¬°üÀ¨Á½¸ö½Ó¿ÚÖ®¼äµÄ·ÓÉ
IT ͨѶ£º
HTTP ͨѶ֧³Öͨ¹ý×Ô¼ºµÄ web Ò³·ÃÎʹý³ÌÊý¾Ý£»
µç×ÓÓʼþ¿Í»§¶Ë¹¦ÄÜ£¬Ö±½Ó´ÓÓû§³ÌÐò·¢ËͰüº¬Éí·ÝÑéÖ¤ÐÅÏ¢µÄµç×ÓÓʼþ£»
FTP ͨѶ֧³Ö³ÌÐò¿ØÖÆµÄ FTP ¿Í»§¶ËͨѶ£»
ͨ¹ý FTP ·þÎñÆ÷·ÃÎÊÊý¾Ý¿é
ͨ¹ý PROFINET ½Ó¿Ú½øÐÐͨѶ·þÎñ
PROFINET IO ¿ØÖÆÆ÷£¬¾ßÓÐʵʱÊôÐÔ£¨RT ºÍ IRT£©
PROFINET CBA
ͨ¹ý DHCP¡¢¼òµ¥µÄ PC ¹¤¾ß»òͨ¹ýÓû§³ÌÐò£¨ÀýÈç HMI£©½øÐÐ IP µØÖ··ÖÅä
Ö§³Ö PROFINET IO É豸µÄÓÅÏÈÆô¶¯
ʹÓà STEP 7 ×é̬
½éÖÊÈßÓà (MRP)£»
ÔÚ²ÉÓû·ÐÎÍØÆË½á¹¹µÄÒÔÌ«ÍøÍøÂçÄÚ£¬CP Ö§³Ö½éÖÊÈßÓà³ÌÐò MRP¡£
ͨ¹ý¿É×é̬µÄ IP ·ÃÎÊÁÐ±í½øÐзÃÎʱ£»¤
ÎÞÐè±à³ÌÆ÷¼´¿É½øÐÐÄ£°å¸ü»»£»
ËùÓÐÐÅÏ¢¶¼±£´æÔÚ C-PLUG ÖУ¨¼´Ê¹ÊÇÓÃÓÚ IT ¹¦ÄܵÄÎļþϵͳ£©¡£
·á¸»µÄÕï¶Ï¹¦ÄÜ£¬¿ÉÓÃÓÚ»ú¼ÜÖеÄËùÓÐÄ£°å
ͨ¹ý SNMP V1 MIB-II£¬¼¯³ÉÔÚÍøÂç¹ÜÀíϵͳÖÐ
ÔËÐÐÓÚÈßÓà S7 ͨѶ»ò DP Ö÷վͨѶµÄ SIMATIC H ϵͳ¡£
ÔÚÓë SIMATIC S7-400 CPU 416F Ò»ÆðʹÓõĹÊÕϰ²È«ÐÍÓ¦ÓóÌÐò (PROFIsafe) ÖвÙ×÷
ÓÃÓÚ¼ò±ã¡¢¿ì½ÝµØ¶ÔS7-400Ä£°å½øÐнÓÏß
¿ÉÌṩÏÂÁÐÄÚÈÝ£º
ǰÁ¬½ÓÆ÷£º
¸ü»»Ä£°åʱÎÞÐèÖØÐ½ÓÏß
TOP Á¬½Ó£º
ÓÃÓÚ¿ìËÙ¡¢ÎÞ¹ÊÕϵØÁ¬½Ó´«¸ÐÆ÷ºÍÖ´ÐÐÆ÷£¬Á¬½Ó¾àÀë¿É´ï30m
Flexible(ÈáÐÔ)Á¬½Ó£º
¿ÉÒÔ¿ìËÙ¡¢Ö±½ÓµØ½«SIMATIC S7-400Á¬½Óµ½¿ØÖƹñÖеÄÿ¸ö¿ØÖƵ¥ÔªÉÏ
CPU 1512C-1 PN Êǽô´ÕÐÍ CPU£¬ÓÃÓÚ·ÇÁ¬ÐøÉú²ú¼¼ÊõÖжԴ¦ÀíËٶȺÍÏìÓ¦ËÙ¶ÈÒªÇ󲻸ߵÄÓ¦Óá£
CPU 1512C-1 PN ¾ßÓÐ 5 µãÄ£ÄâÁ¿ÊäÈ룻ͨ¹ýÕâЩÊäÈ룬¿ÉÒԼǼѹÁ¦»òζȵÈÄ£Äâ¹ý³ÌÐźš£ÆäÖÐ 4 µã¸öÊäÈë¿ÉÓÃÓÚµçÁ÷»òµçѹ²âÁ¿£¬1 µãÊäÈë¿ÉÓÃÓÚµç×è²âÁ¿¡£
CPU ÉϵÉÄ£ÄâÁ¿Êä³ö½« 16 λÊý×Öֵת»»ÎªµçÁ÷»òµçѹ²¢Êä³öµ½¹ý³Ì¡£ÀýÈ磬ËüÃÇÊʺϿØÖƱÈÀý·§¡£
½èÖúÓÚ 32 µã¼¯³ÉʽÊý×ÖÁ¿ÊäÈ룬¿ÉÔÚ¿ØÖÆÆ÷ÉÏÖ±½Ó¼Ç¼À´×ÔÉ豸µÄ 24 V DC Ðźš£
32 µã¼¯³ÉʽÊý×ÖÁ¿Êä³ö¿ÉÒÔÇл» 24 V DC µçѹ£¬´Ó¶ø½«ÄÚ²¿ÐźŴӿØÖÆÆ÷´«Ë͵½É豸¡£
¼¯³ÉµÄ¼ÆÊýÆ÷¿É¼Ç¼Ëٶȸߴï 100 kHz µÄÐźŲ¢Ö±½ÓÔÚ¿ØÖÆÆ÷ÖзÖÎö¼ÆÊýÆ÷״̬»òµ±Ç°ËÙ¶È£¬ÎÞÐèʹÓø½¼ÓÄ£¿é¡£ËÙ¶È¿ÉÒÔÆµÂÊ»òÖÜÆÚµÄÐÎʽÊä³ö£¬»òÒÔÓû§¹éÒ»»¯ËٶȵÄÐÎʽÊä³ö¡£
CPU µÄÔ˶¯¿ØÖƹ¦Äܿɽ«¼ÆÊýÆ÷ÓÃ×÷ʵ¼ÊλÖÃÖµ£¬½«Ä£ÄâÁ¿Êä³öÓÃ×÷ËÙ¶ÈÉ趨ֵÊä³ö¡£ÁíÍ⣬CPU ͨ¹ýÒ××é̬µÄ¿éÌá¹©È«Ãæ¿ØÖƹ¦ÄÜ£¬ÒÔ¼°Í¨¹ý±ê×¼»¯ PLC-open ¿é ÌṩÁ¬½ÓÖÁÇý¶¯Æ÷µÄÄÜÁ¦¡£
CPU 1512C-1 PN ¿É±»ÓÃ×÷ PROFINET IO ¿ØÖÆÆ÷»ò·Ö²¼ÖÇÄÜϵͳ£¨PROFINET ÖÇÄÜÉ豸£©¡£¼¯³Éʽ PROFINET IO IRT ½Ó¿ÚÉè¼ÆÎªË«¶Ë¿Ú½»»»»úÒÔ±ãÔÚϵͳÖÐÉèÁ¢×ÜÏßÐÍÍØÆË¡£
CPU 1512C-1 PN ¾ßÓУº
¹¦ÄÜÇ¿´óµÄ´¦ÀíÆ÷£º
¸Ã CPU µÄµ¥Ìõ¶þ½øÖÆÃüÁîµÄÃüÁîÖ´ÐÐʱ¼ä¿ÉµÍÖÁ 60 ns¡£
´óÈÝÁ¿¹¤×÷´æ´¢Æ÷£º
250 KB ÓÃÓÚ³ÌÐò£¬1 MB ÓÃÓÚÊý¾Ý
¼¯³ÉÊäÈë/Êä³ö£»
32 µãÊý×ÖÁ¿ÊäÈëºÍ 32 µãÊý×ÖÁ¿Êä³öÒÔ¼° 5 µãÄ£ÄâÁ¿ÊäÈëºÍ 2 µãÄ£ÄâÁ¿Êä³ö£¨ÓÃÓÚµçÁ÷/µçѹÐźţ©£¬²¢¾ßÓÐÒ»¸öÓÃÓÚ²âÁ¿ CPU ζȵĸ½¼ÓÊäÈë¡£
SIMATIC ´æ´¢¿¨×÷Îª×°ÔØ´æ´¢Æ÷£º
¾ßÓÐÊý¾Ý¼Ç¼ºÍ¹éµµµÈ¸½¼Ó¹¦ÄÜ
Áé»îµÄÀ©Õ¹¹¦ÄÜ£º
µ¥²ã×é̬×î¶à¿ÉÖ§³Ö 32 ¸öÄ£¿é£¨CPU + 31 ¸öÄ£¿é£©
¾ßÓÐÒÔϹ¦ÄܵįÁÄ»»Ã棺
ÏÔʾ¸ÅÀÀÐÅÏ¢£¬ÀýÈ磺¼¯³É½Ó¿ÚµÄ IP µØÖ·¡¢Õ¾Ãû³Æ¡¢É豸Ãû³Æ¡¢Î»Öñêʶ·ûµÈ
ÏÔʾÕï¶ÏÐÅÏ¢
Ä£¿éÐÅÏ¢ÏÔʾ
ÏÔʾ¿ÉÓÉÓû§¶¨ÒåµÄ»Õ±ê
ÏÔʾÏÔʾÆÁÉèÖÃ
ÉèÖà IP µØÖ·
ÉèÖÃÈÕÆÚºÍʱ¼ä
Ñ¡ÔñÔËÐÐģʽ
½« CPU ¸´Î»Îª³ö³§ÉèÖÃ
½ûÓÃ/ÆôÓÃÏÔʾ
ÆôÓñ£»¤¼¶±ð¡£
PROFINET IO IRT ½Ó¿Ú£º
¾ßÓÐͨ¹ý PROFINET Á¬½Ó·Ö²¼Ê½ I/O µÄÑ¡¼þ¡£