E+HÒô²æÎïλ¼Æ/Òô²æ¿ª¹ØFTL31-AA1U2AAWBJµÂ¹úE+HϵÁÐÊǸ¡×Ó¿ª¹Ø»òµçµ¼Ê½¡¢µçÈÝʽºÍ¹âѧ´«¸ÐÆ÷²úÆ·µÄÀíÏëÌæ´úÆ·ÓÃÓÚ¹ÞÌå¡¢ÈÝÆ÷ºÍ¹ÜµÀÖеÄÒºÌåÏÞλ¼ì²â¡£»¹ÄܶÔÇåÏ´ºÍ¹ýÂËϵͳ£¬ÒÔ¼°ÀäÈ´¼Á¹ÞºÍÈó»¬Ó͹ÞÖÐÌṩÒç³ö±£»¤»ò±Ã¿Õת±£»¤¡£²Ù×÷°²È«£¬ÔËÓù㷺¡£
Ò»¡¢Òô²æÎïλ¼Æ/Òô²æ¿ª¹ØFTL31-AA1U2AAWBJµÂ¹úE+HµÄÌØµã
½ô´Õ£º
Êг¡ÉÏ×îС³ß´çµÄÒô²æ´«¸ÐÆ÷
°²È«£º
Á¬Ðø×Ô¼à¿Ø£»¿É¿¿¿ª¹Ø¶¯×÷£¬²»ÊܽéÖÊÊôÐÔµÄÓ°Ïì
¼òµ¥£º
ÎÞÐè±ê¶¨»òµ÷½Ú£»¼´²å¼´ÓÃ
¶þ¡¢Òô²æÎïλ¼Æ/Òô²æ¿ª¹ØFTL31-AA1U2AAWBJµÂ¹úE+HµÄÓÅÊÆ
1¡¢Éè¼Æ·ûºÏ¸ßÖÊÁ¿ºÍ»·¾³³ÖÐøÐÔÒªÇ󣬼á¹ÌÄÍÓõIJ»Ðâ¸ÖÍâ¿Ç¡£
2¡¢²ÉÓýô´ÕÐͽṹÉè¼Æ£¬¿ÉÒÔÔÚÏÁС¿Õ¼äÖÐÇáËɰ²×°Ê¹ÓÃ
3¡¢¼´Ê¹ÔÚ½éÖʱ仯µÄ³¡ºÏÖУ¬ÎÞÐèµ÷½Ú£¬Êµ¼ÊÒ²ÄÜʹÓü´²å¼´ÓõĴ«¸ÐÆ÷¡£²âÁ¿²»Êܵ絼ÂÊ¡¢Õ³¸½¡¢ÈŶ¯¡¢Á÷¶¯»òÆøÅݵÄÓ°Ïì
4¡¢ÎÞÐè±ê¶¨£¬ÎÞÐèÌØ¶¨ÖªÊ¶»ò¹¤¾ß(ÀýÈ磺Èí¼þ)
5¡¢Ä£¿é»¯Éè¼ÆÌṩ²»Í¬¹ý³ÌζȺÍÊг¡É϶àÑùµÄ¹ý³ÌÁ¬½ÓºÍ¸½¼þ£¬Âú×ãÿ¸öÓ¦ÓÃÒªÇó
6¡¢Ê¹ÓÃLED ָʾµÆ±êʶÏÖ³¡¹¦Äܼì²â

Èý¡¢Òô²æÎïλ¼Æ/Òô²æ¿ª¹ØFTL31µÄÓ¦ÓÃÁìÓò
FTL31Êǿɿ¿µÄÏÞλ¼ì²â¿ª¹Ø£¬²ÉÓýô´ÕÐÍÉè¼Æ£¬´ø²»Ðâ¸ÖÍâ¿Ç£»ÊÊÓÃÓÚËùÓÐÐÐÒµµÄÒ»°ã¹¤ÒµÓ¦Óã¬ÀýÈç°²×°¿Õ¼äÏÁСµÄOEMÉ豸¡£
¹ý³ÌÁ¬½Ó£ºÂÝÎÆ
ζȣº-40...+150°C (-40...+302°F)
ѹÁ¦£º-1...+40bar (-14.5...580psi)
±íÃæ¹â½à¶È£º3.2µm
ÈÏÖ¤£ºWHGÒç³ö±£»¤ºÍй©¼ì²â¡¢CSA C/US¡¢3.1²ÄÁÏÖ¤Êé¡¢´¬¼¶ÈÏÖ¤¡¢×îÖÕ¼ì²â±¨¸æ
ËÄ¡¢Òô²æÎïλ¼Æ/Òô²æ¿ª¹ØFTL31ÌØÕ÷ºÍ¹æ¸ñ
²âÁ¿ÔÀí
|
ÒºÌåÒô²æ
|
ÌØµã/Ó¦ÓÃ
|
Level switch for liquids and is used in tanks, vessels and pipes.
|
µçÔ´/ͨÐÅ
|
20 ... 253V AC/DC, 2-wire
10 ... 30V DC-PNP 3-wire
|
»·¾³Î¶È
|
-40 °C ... 70 °C
(-40 °F ... 158 °F)
|
¹ý³ÌζÈ
|
-40 °C ... 150 °C
(-40 °F ... 302 °F)
|
¹ý³ÌѹÁ¦£¨¾øÑ¹£©/×î´ó¹ýѹÏÞ¶¨Öµ
|
Vacuum ... 40 bar
(Vacuum ... 580 psi)
|
½éÖʵÄ×îСÃܶÈ
|
>0,7g/cm³
(>0,5g/cm³ optional)
|
Ö÷Òª½ÓÒº²¿¼þ
|
316L
|
¹ý³ÌÁ¬½Ó
|
Threads:
G1/2, G3/4, G1, MNPT1/2, MNPT3/4, MNPT1, R1/2, R3/4, R1
|
ͨÐÅ
|
AC/DC, DC-PNP
|
Ö¤Êé/ÈÏÖ¤
|
CSA C/US, EAC
|
°²È«ÈÏÖ¤
|
Overfill prevention WHG
Leakage
|
Éè¼ÆÈÏÖ¤
|
EN 10204-3.1
|
´¬¼¶ÈÏÖ¤
|
ABS/ LR/ BV/ DNV
|
Ñ¡Ïî
|
Adjustment switching delay
Cleaned from oil+grease,
PWIS free
|
FTL31ϵÁоßÌåÐͺţº
FTL31-AA4U2AAWBJ
FTL31-AA4M2AAWBJ
FTL31-AA4U2AAW5J