¸ÃϵÁвúÆ·ÊÇÒ»¿îÕë¶ÔµçÁ¦Åä¡¢Óõ糡¾°´æÔÚ´óÁ¿Ä©¶Ë¸ÐÖªÉ豸ÐèÒª½ÓÈëϵͳµÄ“±ßÔµ²à¶àÀàÐÍͨÐŽӿÚ×ÔÊÊÓ¦”µÄ¹¤Òµ¼¶ ONUÉ豸¡£Ìṩ¿ÉÑ¡µÄ2×GPON/2×GEPON£¬4G/5G LTEµÈ¶àÖÖÉÏÐÐÍøÂç½Ó¿Ú£¬Ìṩ8¸öGEµç¿Ú+4¸öRS485/R232´®¿Ú£¬ÒÔ¼°4·DI¸æ¾¯½ÓÈ룬2×USBÀ©Õ¹½Ó¿Ú¡£²úÆ·¿ÉÓ¦ÓÃÓÚµçÁ¦ÅäÍø×Ô¶¯»¯ÐÅÏ¢²É¼¯ºÍ´«Ê䣬µçÁ¦»ú·¿¶àÒµÎñÄ©¶Ë¸ÐÖªÉ豸½ÓÈ룬Ҳ¿ÉÂú×ãÊÓÆµ¼à¿ØµÈ½¨ÉèÒªÇó¡£
¸ÃϵÁвúÆ·EPON½ÓÈë×ñÑIEEE802.3ah£¬Âú×ã¡¶YD/T 1475-2006½ÓÈëÍø¼¼ÊõÒªÇó——»ùÓÚÒÔÌ«Íø·½Ê½µÄÎÞÔ´¹âÍøÂç(EPON)¡·ºÍ¡¶ÖйúµçÐÅEPON É豸¼¼ÊõÒªÇóV3.1¡·ÖжÔÓÚGEPON OUNÉ豸µÄÏà¹ØÒªÇó¡£Í¬Ê±£¬×ñѵçÁ¦ÐÐÒµµÄÖ÷ҪͨÐűê×¼¡¶»ùÓÚÒÔÌ«Íø·½Ê½µÄÎÞÔ´¹âÍøÂ磨EPON£©ÏµÍ³¡·ºÍµçÁ¦ÐÐÒµ¹¤Òµ¼¶ÒªÇóµÄÏà¹Ø¹æ·¶¡£²ÉÓÃÍøÂç±ê×¼Æä¿ª·ÅÐԺá¢Ó¦Óù㷺¡¢Ê¹ÓõÄÊÇ͸Ã÷¶øÍ³Ò»µÄTCP/IPÐÒ飬ÒÔ¼°±ê×¼»¯µÄOAMºÍSNMP¹ÜÀí¡£
GPON½ÓÈë×ñÑITU G.984ϵÁбê×¼£¬Âú×ã¡¶GB/T33845-2017½ÓÈëÍø¼¼ÊõÒªÇó——¼ª±ÈÌØµÄÎÞÔ´¹âÍøÂ磨GPON£©¡·£¬¡¶YD/T1949-2009½ÓÈëÍø¼¼ÊõÒªÇó——¼ª±ÈÌØµÄÎÞÔ´¹âÍøÂ磨GPON£©¡· ºÍ ¡¶ÖйúµçÐÅGPON É豸¼¼ÊõÒªÇóV2.0¡·ÖжÔÓÚGPON ONTÉ豸µÄÏà¹ØÒªÇ󣬼æÈÝÐԺã¬Ö§³Ö±ê×¼»°µÄOMCIºÍSNMP¹ÜÀí¡£
¸ÃϵÁвúÆ·Ö§³Ö4G/5G LTEÎÞÏßÔËÓªÉÌÍøÂç½ÓÈë»òÕß±¸·Ý£¬Ôö¼Ó²úÆ·µÄ¿É¿¿ÐÔ¡£¿ÉÁé»î¸ù¾ÝÓû§ÒªÇó£¬Ñ¡Ôñ²»Í¬ÍøÂçÓÅÏȲßÂÔ£¬±£Ö¤ÏµÍ³µÄ¿É¿¿ÐÔ¡£
Ö§³Ö8¸öGEÒÔÌ«Íø½ÓÈ룬·½±ã½ÓÈëÍøÂçÉãÏñ»ú£¬ÍøÂçÖն˲ɼ¯É豸£¬Ö§³Ö4¸öRS232/485½Ó¿Ú£¬¿É¶þ´Î¿ª·¢£¬Ö§³Ö¶àÖÖϹÒÖÕ¶ËÉ豸µÄ¶àÐÒé½ÓÈ룬Âú×ã¶àÖÖÄ©¶Ë¸ÐÖª/²É¼¯É豸½ÓÈëÒªÇó¡£²¢Ö§³Ö4·DIÊäÈë¸æ¾¯£¬¿ìËÙ½ÓÈë¸æ¾¯Ðźš£
Ó¦Óó¡¾°

XP3210Ó¦ÓÃÓÚµçÁ¦ÏµÍ³µÄ±ßÔµ²à×ۺϽÓÈ룬֧³ÖÔ¶³ÌÐÅÏ¢²É¼¯ºÍ´«Ê䣬ÔÚPONµÄÍøÂçÖУ¬Í¨¹ýÁ½¸öPONÉÏÐе½²»Í¬µÄOLT£¬Æðµ½ÍøÂç±£»¤×÷Óã»ÔÚÒÔÌ«ÍøÍøÂç»·¾³ÖУ¬Í¨¹ýË«GEÐγÉERPS»·Íø£¬Í¨¹ý»·Çл»±£»¤£¬Æðµ½ÍøÂç±£»¤×÷Óã¬Í¬Ê±£¬ÔÚÓÐÏßÍøÂç¹ÊÕÏÇé¿öÏ£¬»¹¿ÉÒÔͨ¹ý4G/5G LTEÍøÂç×÷Ϊ½ô¼±±¸·Ý£¬¼°Ê±¸æÖª¹ÊÕÏ£¬·½±ãÔ¶³Ì¹ÜÀíºÍά»¤£»ÏÂÐÐͨ¹ýGEºÍ´®¿Ú½ÓÈ뿪±ÕËù£¬»·Íø¹ñ£¬Åäµç·¿µÈÉ豸¡£
²úÆ·ÌØÐÔ
Ë«PONË«MACÉè¼Æ£¬¼áÇ¿Áé»îµÄ×éÍøÄ£ÐÍ¡£Ö§³ÖGPON/EPON×ÔÊÊÓ¦¡£
ONU²ÉÓÓÊÖÀÊ֔ȫ±£»¤µ¹»»Ð͵ĸ߿ɿ¿ÐÔÍØÆË½á¹¹£¬µçÍøÍ¨ÐÅÁ´Â·µÄ1+1±£»¤¹¦Äܲ¢ÇÒʵÏÖСÓÚ50ms±£»¤Çл»£¬±£ÕϵçÍøÍ¨ÐÅϵͳµÄ¿É¿¿ÔËÐС£Ö§³ÖTYPE BºÍTYPE CµÄµ¥/Ë«¹éÊôÒµÎñ±£»¤¡£´ËÍ⣬¸ù¾Ýʵ¼ÊÅäÍø½á¹¹µÄ²»Í¬£¬Ò²¿ÉÒÔÁé»î²ÉÓÃÊ÷ÐΡ¢Á´ÐÍÊÖÀÊÖ¡¢»·ÐεȽṹ¡£
¶àÖÖÍøÂç½ÓÈë
¿ÉÖ§³ÖGPON/EPON×ÔÊÊÓ¦£¬Âú×㲻ͬµÄ½¨ÍøÐèÇó¡£É豸¿ÉÁé»îÑ¡ÔñGPON/EPONÎÞÔ´¹âÍøÂç¡£
Ö§³ÖÎÞÏß¹ãÓòÍø4G/5G LTE±¸·Ý£¬ÓÐÏßÍøÂç¹ÊÕÏʱÄÜ¿ìËÙµ¹»»µ½ÎÞÏßÍøÂ磬±£Ö¤ÍøÂ糩ͨ£¬·½±ãʵÏÖÔ¶³Ì¹ÜÀíºÍÎÞÈËÖµÊØ¡£ÌØÊⳡ¾°Ò²¿ÉÒÔÖ§³Ö4G/5GÒµÎñ½ÓÈ룬·½±ãÍøÂ粿Êð¡£
Ìṩ¶àÒµÎñµÄQOS±£ÕÏ
Ö§³Ö»ùÓÚGPON/EPON/GEµÄQOS²ßÂÔ£¬Áé»î·ÖÅä´ø¿í£¬Çø·Ö¶àÖÖÒµÎñÓÅÏȼ¶£¬±£Ö¤¶àÒµÎñ½ÓÈ룬»ñµÃÏàÓ¦µÄÖÊÁ¿±£ÕÏ¡£
ÏȽøµÄ²úÆ·¼Ü¹¹
²úÆ·Ä£¿é»¯Éè¼Æ£¬Ö§³Ö¶àÖÖ¶¨ÖÆÐèÇó£¬Ë«µçÔ´¹©µç£¬°²È«¿É¿¿¡£²úÆ·¹©µç¿ÉÑ¡ÔñÖ§³ÖAC220V»òDC48V¡£È«¸²¸ÇÅäÍø»·¾³¶ÔÓÚÉ豸µçÔ´µÄÒªÇó¡£
·á¸»µÄÒÔÌ«Íø¹¦ÄÜ
Ö§³Ö8¸ö10/100/1000M×ÔÊÊÓ¦ÒÔÌ«Íø½Ó¿Ú£¬Ö§³Ö6KV·ÀÀËÓ¿±£»¤¡£¹¦ÄÜÌØÐԾ߱¸ÓÐЧµÄ¸ôÀë±£ÕÏ»úÖÆ¡¢VLAN¸ôÀë¡¢±£»¤¶Ë¿Ú¡¢MACµØÖ·°ó¶¨¡¢IPµØÖ·°ó¶¨¡¢¶Ë¿ÚÏÞËÙ¡¢¶ÓÁм¼Êõ¡¢Á÷¿Ø¼¼ÊõµÈΪ¶àÒµÎñÈںϵĿªÕ¹Æðµ½Á˼¼Êõ±£ÕÏ£¬ÄÜÆ½»¬Éý¼¶À©ÈÝ¡£
¼æÈÝÖ÷Á÷³§ÉÌ»ªÎª¡¢·é»ðµÈOLT
ÃæÏòÒµÎñ£¬ÌṩͳһµÄÍøÂç´«ÊäºÍ»¥ÁªÐÒé¡¢¼æÈÝ»ªÎª¡¢·é»ðµÈOLT¶Ô½Ó¡£Âú×ã¶àÒµÎñÐèÇ󣬷ḻµÄOAM/OMCI¹¦ÄÜ£¬Ò×ѧÒ×Óá£
Õë¶ÔµçÁ¦ÏµÍ³µÄ¹¤Òµ¼¶Éè¼Æ
ONU¾ß±¸Ë«PONÉÏÐУ¬ÌṩGPON/GEPON¡¢GEǧÕ×Íø¿Ú¡¢RSRS232/485µÈÒµÎñ½Ó¿Ú¡£Õû»ú¾ß±¸Íø¿Ú6KV·ÀÀËÓ¿ÄÜÁ¦£¬-40¡æ¡«75¡æ¿í¹¤×÷ζȷ¶Î§µÈ£¬Äܹ»ÊÊÓ¦¸÷ÖÖ¶ñÁÓ»·¾³£¬¿¹Ç¿À×»÷ºÍÇ¿µç´Å¸ÉÈÅ£¬·ûºÏGB/T17626µç´Å¼æÈÝ4¼¶±ê×¼¡¢°²¹æµÈÒªÇó¡£
씀|
ÃèÊö
|
¹Ì¶¨ÅäÖýӿÚ
|
2*GEPON/GPON¹Ì¶¨½Ó¿Ú£»
8*GE½Ó¿Ú£»
4*RS232/RS485½Ó¿Ú
1*Console¹ÜÀí½Ó¿Ú£»
1*DI£¨4·£©¸æ¾¯ÊäÈë½Ó¿Ú
2*USB2.0À©Õ¹½Ó¿Ú
|
PON½Ó¿Ú
|
ÉÏÏÂÐжԳÆ1.25Gbps´«ÊäËÙÂÊ£¨EPON£©£»ÏÂÐÐ2.5Gbps/ÉÏÐÐ1.25Gbps£¨GPON£©
|
ÍøÂ縲¸Ç°ë¾¶: 20¹«Àï
|
¹â½Ó¿ÚÀàÐÍ£ºSC/PC
|
·¢Ë͹⹦ÂÊ£º0¡«4dbm
|
½ÓÊÕ¹âÁéÃô¶È:≤ -27dBm
|
°²È«ÐÔ: ONUÖ§³ÖMACµØÖ·ÈÏÖ¤»úÖÆ£¬GPONÖ§³ÖOID/SNÈÏÖ¤
|
Ö§³Ö¹â¹¦Âʼì²âµÈDDMI¹¦ÄÜ
|
4G½Ó¿Ú
|
USB½Ó¿Ú¿¨£¬Ö§³Ö4GÄ£¿éÀ©Õ¹¡£
|
5G½Ó¿Ú
|
USB½Ó¿Ú¿¨£¬Ö§³Ö5GÄ£¿éÀ©Õ¹¡£
|
USB½Ó¿Ú
|
2¸öUSB2.0À©Õ¹½Ó¿Ú£¬¿ÉÍâÀ©USBÉ豸£º4G/5GÍø¿¨£¬UÅÌ´æ´¢£¬WIFIÉ豸£¬´®¿Ú£¬DI/DOÉ豸µÈ
|
´®¿Ú
|
´®¿ÚÀàÐÍ£ºÖ§³ÖRS232¡¢RS485ȫ˫¹¤/°ëË«¹¤
|
×î´ó¶Ë¿ÚËÙÂÊ£º 115200bps
|
»á»°ÀàÐÍ£ºÖ§³ÖTCP Server¡¢TCP Client¡¢UDP
|
Ö§³Ö͸´«IEC60870-5-101/104¡¢IEC61850¡¢CDT¡¢DNPµÈ¶àÖÖµçÁ¦Í¨ÐŹæÔ¼
|
¸æ¾¯¶Ë¿Ú
|
Ö§³Ö±¨¾¯ÊäÈë½Ó¿Ú
|
¶þ²ã¹¦ÄÜ
|
VLANÊýÁ¿£º4K£¬Ö§³ÖVLAN Tag¡¢untag¡¢1:1VLAN¡¢N:1VLAN¡¢VLAN͸´«µÈ
|
Ö§³ÖVLANת»»µÈ¹¦ÄÜ
|
Ö§³ÖSTP¹¦ÄÜ
|
Ö§³Ö¶Ë¿Ú¾µÏñ¹¦ÄÜ
|
Ö§³ÖUNI¶Ë¿ÚÁ÷¿Ø¹¦ÄÜ
|
Ö§³ÖIGMP Snooping
|
·þÎñÖÊÁ¿
|
±³Ñ¹Ê½Á÷¿Ø£¨°ëË«¹¤£©¡¢IEEE 802.3xÁ÷¿Ø£¨È«Ë«¹¤£©
|
IEEE 802.1p, CoS
|
WR¡¢SPºÍFIFO¶ÓÁе÷¶ÈËã·¨
|
¶Ë¿ÚÏÞËÙ
|
Ö§³ÖµÄÒµÎñÁ÷·ÖÀà
|
°²È«¹¦ÄÜ
|
Ö§³Ö½ÓÈëÉ豸ÈÝÁ¿ÏÞÖÆ¡¢MACµØÖ·¹ýÂ˹¦ÄÜ
|
Ö§³ÖUNI½Ó¿ÚÖ®¼ä°²È«¸ôÀ빦ÄÜ
|
Ö§³Ö»ùÓÚÓ¦ÓòãÐÒé¶Ë¿ÚºÅ¡¢IP¡¢Ô´Ä¿µÄMAC¡¢VLANidµÄÊý¾ÝÁ÷¹ýÂ˹¦ÄÜ
|
Ö§³Ö¹ã²¥¡¢×é²¥¡¢Î´Öªµ¥²¥µÄ±¨ÎÄÒÖÖÆ¹¦ÄÜ
|
Ö§³ÖUNI¶Ë¿Ú»·Â·¼ì²â¹¦ÄÜ
|
¿É¿¿ÐÔ
|
Ö§³ÖË«PON¿Ú“1+1”±£»¤×Ô¶¯Çл»ºÍ»Ö¸´£¬Çл»ºÍ»Ö¸´Ê±ÑÓ<50ms
|
Ö§³ÖGE¹â½Ó¿ÚÒÔÌ«ÍøERPS»·Íø¹¦ÄÜ£¬µ¹»»Ê±ÑÓ<50ms
|
MTBF: 50000Сʱ
|
¹ÜÀíÅäÖÃ
|
CLI, SNMP, TELNETµÈ¶àÖÖ¹ÜÀí·½Ê½
¿Éͨ¹ýTFTP¡¢OAMµÈ·½Ê½½øÐÐÈí¼þÉý¼¶
|
»úÏä
|
»úÏä³ß´ç£¨W×H×D£© 280mm×165mm×44mm
|
·À»¤µÈ¼¶IP40
|
ÎÞ·çÉÈ¡¢ÂÁºÏ½ð»úÏäÉ¢ÈȱíÃæÉè¼Æ
|
ÖØÁ¿£º1.0 Kg
|
µçÔ´
|
Ö§³ÖÖ±Á÷DC48VµÈ¹©µç£¨AC220V ¿ÉÑ¡£©
|
¶î¶¨¹¦ºÄ < 20W
|
»·¾³Ö¸±ê
|
¹¤×÷»·¾³£ºÎ¶È-40¡æ¡«75¡æ
|
´æ´¢»·¾³£ºÎ¶È-40¡æ¡«85¡æ
|
Ïà¶Ôʪ¶È£ºÊª¶È5%¡«95%ÎÞÀäÄý
|
¶©¹ºÁÐ±í£º
²úÆ·ÐͺÅ
|
¶Ë¿Ú
|
µçÔ´
|
XPON¿Ú
|
ǧÕ×µç¿ÚRJ45
|
RS232/485´®¿Ú
|
IP3000-3206-2GP-4R2-2DC
|
2xGPON
|
4
|
4
|
˫24/48VDC
|
IP3000-3210-2GP-4R2-2DC
|
2xGPON
|
8
|
4
|
˫24/48VDC
|
XP3000-3210-2XP-4R2-2DC
|
2¸öGPON/GEPON¶þºÏÒ»
|
8
|
4
|
˫24/48VDC
|
IP3000-3206-2GP-4R2-AC
|
2xGPON
|
4
|
4
|
µ¥90~260VAC
|
IP3000-3210-2GP-4R2-AC
|
2xGPON
|
8
|
4
|
µ¥90~260VAC
|
XP3000-3210-2XP-4R2-AC
|
2¸öGPON/GEPON¶þºÏÒ»
|
8
|
4
|
µ¥90~260VAC
|