Ê×Ò³ - ÐÂÎÅ - ÕÐÆ¸ - ÏÂÔØ - ²úÆ· - ³§ÉÌ - ·½°¸ - ÎÄÕª - Çó¹º - Õ¹ÀÀ
Ãâ·Ñ×¢²á µÇ¼ | ¹ã¸æ·þÎñ | ¿Í·þÖÐÐÄ
Öлª¹¤¿ØÍø ¡ú ¹¤¿Ø²úÆ· ¡ú MOXA ¹¤Òµ¼¶¹âµçת»»Æ÷ IMC-101
²úÆ·Ãû³Æ£º MOXA ¹¤Òµ¼¶¹âµçת»»Æ÷ IMC-101
ÐÍ ºÅ£º IMC-101
¼Û ¸ñ£º 0.00
Æ· ÅÆ£º
 
Êղش˲úÆ·     ²é¿´ÊÕ²Ø
Ö§³Ö Link Fault Pass-Through
Ìṩ¿íΠ(-40~75¡ãC) ²Ù×÷»úÐÍ
µçÔ´¹ÊÕÏ£¬¶Ï¿ÚÖжϣ¬¿ÉÓм̵çÆ÷Êä³ö±¨¾¯
˫ֱÁ÷¿ÉÈßÓà 24 VDC µçÔ´ÊäÈë
ÊÊÓÃÓÚÑÏ¿Á¹¤Òµ»·¾³

¸ÅÊö

MOXA ¹¤Òµ¼¶¹âÏËת»»Æ÷ IMC-101£¬ÌرðÊÊÓÃÓÚÑÏ¿ÁµÄ¹¤Òµ»·¾³£¬ÆäÖ§³Ö 10/100BaseT(X) ¼° 100BaseFX ¼ä¹¤Òµ¼¶Ã½½éµÄת»»£¬ÄÜÌṩϵͳÐÅÀµÇÒÎȶ¨ÐÔµÄÔË×÷¡£IMC-101 ¿É¿¿ÍêÉÆµÄ¹¤ÒµÉè¼Æ£¬Èù¤Òµ×Ô¶¯»¯Ó¦ÓóÖÐøË³³©£¬Í¬Ê±±¸ÓÐ relay Êä³ö¾¯¸æ¹¦ÄÜÒÔ·ÀÖ¹¸÷ÖÖË𺦼°Ëðʧ¡£

IMC-101 ÌØ±ðÊÊÓÃÓÚÑÏ¿ÁµÄ¹¤Òµ»·¾³£¬ÈçΣÏÕ³¡Ëù (class 1, division 2 or zone 2) ¼°±ØÐè×ñÊØ FCC¡¢T¨¹V¡¢UL ¼° CE µÈ±ê×¼µÄ×÷Òµ»·¾³¡£³ýÁËÖ§³Ö 0 µ½ 60¡ãC µÄ²Ù×÷ζÈÍ⣬ÒàÊÊÓÃÓÚ -40 µ½ 75¡ãC µÄ²Ù×÷ζȡ£ÔÙÕߣ¬IMC-101 ²úƷͨ¹ý 100% ÉÕ»ú²âÊÔ£¬¸ü¼ÓÈ·±£ÆäÊÊÓÃÓÚ¹¤Òµ×Ô¶¯»¯¿ØÖÆ»·¾³¡£

Link Fault Pass-Through
IMC-101µÄ"Link Fault Pass-Through" ÌØÐÔ¿Ë·þÁË´«Í³¹âÏËÊÕ·¢Æ÷ËùÓöµ½µÄÎÊÌ⣬¼´µ±Á¬½ÓµÄÒ»±ß·¢ÉúÁ¬½Ó´íÎó£¬ÁíÍâÒ»±ßÈÔÈ»·¢ËÍÊý¾Ý°ü£¬½Ó×ŵȴýʧȥÁ¬½ÓµÄÒ»¶ËÓÀÔ¶ÎÞ·¨µ½´ï¡£
IMC-101 Ëù×öµÄ¾ÍÊÇÒ»µ©¼ì²âµ½Ò»¶ËÁ¬½Óʧ°Ü£¬¾ÍÇ¿ÖÆ¹Ø±Õ£¬ÁíÒ»¶ËÔÊÐíÁ¬ÐøÓ¦ÓÃÈí¼þ¶ÔÕâ¸öÇé¿ö½øÐÐÏàÓ¦´¦Àí¡£

ÈßÓàµçÔ´ÊäÈë
IMC-101 ÌṩÁËÁ½Â·µçÔ´ÊäÈ룬ÔÊÐíͬʱÓëÏÖ³¡µÄµçÔ´Á¬½Ó¡£Èç¹ûÒ»¸öµçÔ´ÊäÈë³öÏÖ¹ÊÕÏ£¬ÁíÍâÒ»¸öµçÔ´×÷Ϊ±¸Óöø×Ô¶¯ÔËÐУ¬À´Âú×ãIMC-101µÄµçÔ´ÐèÇó¡£

¶Ë¿ÚÖжϺ͵çÔ´¹ÊÕÏʱ£¬¼ÌµçÆ÷Êä³ö±¨¾¯
IMC-101ΪÏÖ³¡µçÔ´¹ÊÕϺͶ˿ÚÁ¬½ÓÖжÏÌṩ¼ÌµçÆ÷Êä³ö±¨¾¯£¬Í¨Öª¹¤³§µÄ¼¼ÊõÈËÔ±£¬ÒÔ±ãÄÜѸËٵIJÉÈ¡Êʵ±µÄ½ô¼±²Ù×÷¡£

ÌØµã

Ö§³Ö Link Fault Pass-Through

Ö§³Ö 10/100BaseT(X) ×ÔÊÊÓ¦ºÍ×Ô¶¯MDI/MDIX ¼ì²â

¶àÄ£ºÍµ¥Ä££¬Å䱸SC »òST ¹âÏËÁ¬½ÓÍ·

¶Ë¿ÚÖжϺ͵çÔ´¹ÊÕÏʱ£¬¼ÌµçÆ÷Êä³ö±¨¾¯

²Ù×÷ζȷ¶Î§: 0 ~ 60¡ãC, ¿íι¤×÷ζÈ: -40 ~ 75¡ãC ( -T ¿íλúÐÍ)
ͨ¹ý Class 1 Div. 2 / Zone 2 ÈÏÖ¤
Ìṩ 40 ¹«Àï»ò 80 ¹«Àﳤ¾àÀë´«ÊäÐͺÅ


¹æ¸ñ
¼¼Êõ

±ê×¼
IEEE802.3, 802.3u, Link Fault Pass-Through

½Ó¿Ú
RJ45 ¿Ú
10/100BaseT(X)

¹âÏË¿Ú
100BaseFX (¿ÉʹÓÃSC, ST Á¬½ÓÍ·)

LED ָʾµÆ
Power, Fault, 10/100, Full/Half Duplex, Collision

Dip¿ª¹Ø
100BaseFX ȫ˫¹¤/°ëË«¹¤Ñ¡Ôñ£¬¶Ï¿ÚÖжϱ¨¾¯ÑÚÂ뿪¹Ø

±¨¾¯Á¬½Ó
һ·¼ÌµçÆ÷Êä³ö£¬µçÁ÷¸ºÔØÄÜÁ¦1A @ 24 VDC





 


¹«Ë¾¼ò½é
²úƷĿ¼
¹©Ó¦ÐÅÏ¢

¹«Ë¾Ãû³Æ£º Ħɯ¹ú¼ÊóÒ×£¨ÉϺ££©ÓÐÏÞ¹«Ë¾
µç »°£º 021 52589955 / Íõ С ½ã
ÊÖ»ú£º
µØ Ö·£º ÉϺ£ÊÐÑÓ°²Î÷·1160ºÅÊ×ÐÅÒø¶¼¹ú¼Ê¹ã³¡18²ã
ÓÊ ±à£º 200052
Ö÷ Ò³£º http://www.moxa.com.cn

¸Ã³§ÉÌÏà¹Ø²úÆ·£º
  • moxa EDR-810ϵÁÐ
  •  
  • moxa MD-119ϵÁÐ º£ÊÂרÓÃÏÔʾÆ÷
  •  
  • moxa MXview2.3ÍøÂç¹ÜÀíÈí¼þ
  •  
  • moxa ioLogik R1241
  •  
  • ioLogik R1240
  •  
  • moxa ioLogik R1214
  •  
  • moxa ioLogik R1212
  •  
  • moxa ioLogik R1210
  •  
  • moxa IEX-402-VDSL2ϵÁÐ
  •  
  • moxa MGate™ 5102-PBM-PNϵÁÐ
  •  
    ¸ü¶à²úÆ·...
      ¹ØÓÚÎÒÃÇ | ÁªÏµÎÒÃÇ | ¹ã¸æ·þÎñ | ±¾Õ¾¶¯Ì¬ | ÓÑÇéÁ´½Ó | ·¨ÂÉÉùÃ÷ | ·Ç·¨ºÍ²»Á¼ÐÅÏ¢¾Ù±¨  
    ¹¤¿ØÍø¿Í·þÈÈÏߣº0755-86369299
    °æÈ¨ËùÓÐ ¹¤¿ØÍø Copyright@ Gkong.com, All Rights Reserved