¸É»É¹ÜÓÖÃûÉà»É¹Ü»ò´Å»É¿ª¹Ø£¬Ó¢ÎÄÃûΪReedSwitch£ºËüÊÇÒ»ÖÖÆøÃÜʽÃÜ·âµÄ´Å¿ØÐÔ»úе¿ª¹Ø£¬¿ÉÒÔ×÷Ϊ´Å½Ó½ü¿ª¹Ø»òÕ߼̵çÆ÷ʹÓã¬Ëü±ÈÒ»°ã»úе¿ª¹ØÌå»ýС¡¢Ëٶȸߡ¢¹¤×÷ÊÙÃü³¤£¬Óëµç×Ó¿ª¹ØÏà±È£¬ËüÓÖÓп¹¸ºÔسå»÷ÄÜÁ¦Ç¿µÄÌØµã£¬¹¤×÷¿É¿¿ÐԺܸߡ£ÔÚÊÖ»ú¡¢ÎÀÐÇÌìÏß¡¢ÒûË®»ú¡¢¿§·È»ú¡¢¼Óʪ»ú¡¢³Ì¿Ø½»»»»ú¡¢¸´Ó¡»ú¡¢Ï´Ò»ú¡¢µç±ùÏä¡¢ÕÕÏà»ú¡¢Ïû¶¾Íë¹ñ¡¢ÃÅ´Å¡¢µç´Å¼ÌµçÆ÷¡¢µç×ÓºâÆ÷¡¢ÒºÎ»¼Æ¡¢Ô¶´«ÃºÆø±í\Ë®±í¡¢IC¿¨ÃºÆø±í\Ë®±í¡¢µç×ÓÃºÆø±í\Ë®±íÖж¼µÃµ½¹ã·ºµÄÓ¦Ó㬵ç×Óµç·ÖÐֻҪʹÓÃ×Ô¶¯¿ª¹Ø£¬»ù±¾É϶¼¿ÉÒÔʹÓøɻɹܡ£

INDEX Micro-Miniature Reed Switches Miniature Reed Switches
 
DATA SCAN
ÐÍ ºÅ
Unit HSR--003 MKA--07101 MKA--10110 MKA--14103 MKA-16101
Contact Form
½Ó´¥·½Ê½
  A A A A A
Max. Contact Rating
×î´ó¹¦ÂÊ
W 0.25 1 10 10 10
Max. Switching Voltage
×î´ó¿ª¹Øµçѹ
VDC 30 24 100 100 100
Min. Breakdown Voltage
×îС±ÀÀ£µçѹ
VDC 150 150 150 220 250 220
Max. Switching Current
×î´ó¿ª¹ØµçÁ÷
A 0.01 0.1 0.5 0.5 0.5
Max. Carry Current
×î´ó¸ºÔصçÁ÷
A ---- ---- ---- 1.0 1.0
Max.Intial Contact Resistance
×î´ó½Ó´¥µç×è
m¦¸ 500 200 100 100 100
Min. Insulation Resistance
×îС¾øÔµµç×è
¦¸ 109 109 109 1010 109
Operate time
¶¯×÷ʱ¼ä
ms 0.2 ---- 0.5 0.4 0.3
Bounce time
µ¯ÌøÊ±¼ä
ms ---- ---- 0.2 0.1 0.2
Release time
ÊÍ·Åʱ¼ä
ms ---- ---- 0.3 0.1 0.6
Resonant Frequency
ÏìӦƵÂÊ
Hz ---- 1200 5000 4000 3000
Max. Operating Frequency
×î´ó¹¤×÷îlÂÊ
Hz ---- ---- 400 500 400
Pull in Value
ÁéÃôÖµ
AT 5--20 07--35 10--35 10--25 25--40 10--35
Min. Drop out Value
×îС¸´Î»ÃôÖµ
AT ---- 4 4 5 5
Max. Contact Capacitance
×î´ó½Ó´¥µçÈÝ
PF ---- 0.4 0.5 0.7 0.3
Electrical Life
µçÆøÊÙÃü
(Resistive loads)
¸ºÔØ
    5¡Á107
(50mVDC,10mA)
2¡Á107
(5VDC,10mA)
5¡Á106
(5VDC,10mA)
105
(24VDC,250mA)
108
(5VDC,10mA)
105
(24VDC,400mA)
2¡Á106
(VDC,10mA)
106
(24VDC,250mA)
Test Coll
²âÊÔÏßȦ
Number of turns
ȦÊý
Resistance
µç×è
¦¸   5000
580
5000
580
5000
870
5000
620
INDEX ¡¡ ¡¡Miniature Reed Switches Standard Reed Switches
DATA SCAN
ÐÍ ºÅ
Unit ZM--140/I ZM--109 ZM--116 MKA20101 KAM-2
Contact Form
½Ó´¥·½Ê½
  A A A A A
Max. Contact Rating
×î´ó¹¦ÂÊ
W 10 12 10 10 10
Max. Switching Voltage
×î´ó¿ª¹Øµçѹ
VDC 50 100 150 250 50 150 200 180 180
Min. Breakdown Voltage
×îС±ÀÀ£µçѹ
VDC 100 200 250 400 100 200 250 220 280 250
Max. Switching Current
×î´ó¿ª¹ØµçÁ÷
A 0.5 0.5 0.5 0.5 0.5
Max. Carry Current
×î´ó¸ºÔصçÁ÷
A 1 1.5 1.5 1 1.5 ---- ¡¡
Max.Intial Contact Resistance
×î´ó½Ó´¥µç×è
m¦¸ 100 150 100 150 150
Min. Insulation Resistance
×îС¾øÔµµç×è
¦¸ 109 ---- ---- 109 109
Operate time
¶¯×÷ʱ¼ä
ms 1 ---- ---- ---- ----
Bounce time
µ¯ÌøÊ±¼ä
ms ---- ---- ---- ---- ----
Release time
ÊÍ·Åʱ¼ä
ms 0.1 ---- ---- ---- ----
Resonant Frequency
ÏìӦƵÂÊ
Hz ---- ---- ---- 2600 2400
Max. Operating Frequency
×î´ó¹¤×÷îlÂÊ
Hz ---- ---- ---- ---- ----
Pull in Value
ÁéÃôÖµ
AT 10--15 15--25 25--30 20--60 10--40 10--20 20--40 15--64
Min. Drop out Value
×îС¸´Î»ÃôÖµ
AT ---- ---- ---- ---- ----
Max. Contact Capacitance
×î´ó½Ó´¥µçÈÝ
PF 0.5 ---- ---- 0.4 0.4
Electrical Life
µçÆøÊÙÃü
(Resistive loads)
¸ºÔØ
  10x106
(100VDC,10mA)
3x106
(20VDC,500mA) 100x106
(5VDC,100uA)
---- ---- 106
(24VDC,250mA)
107
(5VDC,10mA)
106
(24VDC,250mA)
3¡Á106
(5VDC,10mA)
Test Coll
²âÊÔÏßȦ
Number of turns
ȦÊý
Resistance
µç×è
¦¸ 10000
1400
---- ---- 5000
550
5000
550
INDEX Standard Reed Switches
DATA SCAN
ÐÍ ºÅ
Unit ZM--107 ZW--103 ZW--104 MRPR-3 MRPR-8
Contact Form
½Ó´¥·½Ê½
  A A A A A
Max. Contact Rating
×î´ó¹¦ÂÊ
W 20 60 180 50 50
Max. Switching Voltage
×î´ó¿ª¹Øµçѹ
VDC 200 300 400 300 00 200 250
Min. Breakdown Voltage
×îС±ÀÀ£µçѹ
VDC 500 500 600 450 600 300 750
Max. Switching Current
×î´ó¿ª¹ØµçÁ÷
A 0.8 3.0 3.0
(7 for pulse switching)
1.5 1.0
Max. Carry Current
×î´ó¸ºÔصçÁ÷
A 2.0 5.0 5.0 3.0 2.5
Max.Intial Contact Resistance
×î´ó½Ó´¥µç×è
m¦¸ 150 100 150 100 100
Min. Insulation Resistance
×îС¾øÔµµç×è
¦¸ ---- ---- ---- 1010 1010
Operate time
¶¯×÷ʱ¼ä
ms ---- ---- ---- 0.75 0.75
Bounce time
µ¯ÌøÊ±¼ä
ms ---- ---- ---- ---- ----
Release time
ÊÍ·Åʱ¼ä
ms ---- ---- ---- 0.3 0.3
Resonant Frequency
ÏìӦƵÂÊ
Hz ---- ---- ---- 2100 2100
Max. Operating Frequency
×î´ó¹¤×÷îlÂÊ
Hz ---- ---- ---- ---- ----
Pull in Value
ÁéÃôÖµ
AT 40--70 40--60 60--100 40--60 60--110 22--43 22--43
Min. Drop out Value
×îС¸´Î»ÃôÖµ
AT ---- ---- ---- ---- ----
Max. Contact Capacitance
×î´ó½Ó´¥µçÈÝ
PF ---- ---- ---- 0.2 0.2
Electrical Life
µçÆøÊÙÃü
(Resistive loads)
¸ºÔØ
  ---- ---- ---- ¡¡ ¡¡
Test Coll
²âÊÔÏßȦ
Number of turns
ȦÊý
Resistance
µç×è
¦¸ ---- ---- ---- L4989 L4989
INDEX High Voltage Reed Switches
¡¡
DATA SCAN
ÐÍ ºÅ
Unit ZP--2 ZP--3 ZP--4 ZP--5 HSR-V7K HSR-V10K
Contact Form
½Ó´¥·½Ê½
  A A A A A A
Max. Contact Rating
×î´ó¹¦ÂÊ
W 50 50 10 10 50 50
Max. Switching Voltage
×î´ó¿ª¹Øµçѹ
VDC 7500 10000 12000 12000 5000 7500
Min. Breakdown Voltage
×îС±ÀÀ£µçѹ
VDC 10000 14000 17000 18000 7500 10000
Max. Switching Current
×î´ó¿ª¹ØµçÁ÷
A 2.0 2.0 2.0 2.0 3.0 3.0
Max. Carry Current
×î´ó¸ºÔصçÁ÷
A 3.0 3.0 3.0 3.0 ---- ----
Max.Intial Contact Resistance
×î´ó½Ó´¥µç×è
m¦¸ 100 100 100 100 100 100
Min. Insulation Resistance
×îС¾øÔµµç×è
¦¸ ---- ---- ---- ---- 1010 1010
Operate time
¶¯×÷ʱ¼ä
ms ---- ---- ---- ---- 3.0 3.0
Bounce time
µ¯ÌøÊ±¼ä
ms ---- ---- ---- ---- ---- ----
Release time
ÊÍ·Åʱ¼ä
ms ---- ---- ---- ----
Resonant Frequency
ÏìӦƵÂÊ
Hz ---- ---- ---- ---- ---- ----
Max. Operating Frequency
×î´ó¹¤×÷îlÂÊ
Hz ---- ---- ---- ---- ---- ----
Pull in Value
ÁéÃôÖµ
AT 100-180 120-200 160-200 160-200 60-125 100-150
Min. Drop out Value
×îС¸´Î»ÃôÖµ
AT ---- ---- ---- ---- ---- ----
Max. Contact Capacitance
×î´ó½Ó´¥µçÈÝ
PF ---- ---- ---- ---- ---- ----
Electrical Life
µçÆøÊÙÃü
(Resistive loads)
¸ºÔØ
  ---- ---- ---- ---- ---- ----
Test Coll
²âÊÔÏßȦ
Number of turns
ȦÊý
Resistance
µç×è
¦¸ ---- ---- ---- ---- ---- ----
INDEX ¡¡ High Power Reed Switches From C Reed Switches
¡¡
DATA SCAN
ÐÍ ºÅ
Unit HSR-V15K MKA--50201 MKA--50202 HSR-V207 MKC--27103 KAM--3
Contact Form
½Ó´¥·½Ê½
  A A A A C C
Max. Contact Rating
×î´ó¹¦ÂÊ
W 50 120 250 2008 30 30
Max. Switching Voltage
×î´ó¿ª¹Øµçѹ
VDC 10000 250 250 2500 200 125
Min. Breakdown Voltage
×îС±ÀÀ£µçѹ
VDC 15000 700 700 7000 350 180 250
Max. Switching Current
×î´ó¿ª¹ØµçÁ÷
A 3.0 3.0 5.0 3.0 1.0 1.0
Max. Carry Current
×î´ó¸ºÔصçÁ÷
A ---- ---- ---- ---- ---- ----
Max.Intial Contact Resistance
×î´ó½Ó´¥µç×è
m¦¸ 100 150 150 500 150 150
Min. Insulation Resistance
×îС¾øÔµµç×è
¦¸ 1010 109 109 1010 0.5¡Á109
1¡Á1010
0.2¡Á109
1¡Á109
Operate time
¶¯×÷ʱ¼ä
ms 3.0 ---- ---- 3.0 ---- ----
Bounce time
µ¯ÌøÊ±¼ä
ms ---- ---- ---- ---- ---- ----
Release time
ÊÍ·Åʱ¼ä
ms ---- ---- ---- ----   ----   ----
Resonant Frequency
ÏìӦƵÂÊ
Hz ---- 700 700 ¡¡ 2200 3000
Max. Operating Frequency
×î´ó¹¤×÷îlÂÊ
Hz ---- ---- ---- ---- ---- ----
Pull in Value
ÁéÃôÖµ
AT 130-170 50--90 50--90 100--150 45--90 30--55 55--80
Min. Drop out Value
×îС¸´Î»ÃôÖµ
AT ---- ---- ---- ---- ---- ----
Max. Contact Capacitance
×î´ó½Ó´¥µçÈÝ
PF ---- 1.0 1.0 ---- 2.0/1.0 2.5/0.5
Electrical Life
µçÆøÊÙÃü
(Resistive loads)
¸ºÔØ
  ---- 1¡Á106
24VDC,250mA
1¡Á104
220V,550mA
1¡Á105
250VDC,1A
---- 5¡Á105
30VDC,100mA
1¡Á105
60VDC,200mA
5¡Á105
24VDC,250mA
1¡Á106
5VDC,10mA
Test Coll
²âÊÔÏßȦ
Number of turns
ȦÊý
Resistance
µç×è
¦¸ ---- 5000
335
5000
335
---- 5000
450
5000
455

 


¹«Ë¾¼ò½é
²úƷĿ¼
¹©Ó¦ÐÅÏ¢

¹«Ë¾Ãû³Æ£º ¶«Ý¸Êи»Åôµç×ÓÖÆÆ·ÓÐÏÞ¹«Ë¾
µç »°£º 0769 83829262 / Ïò·¼Ã·
ÊÖ»ú£º 13798756616
µØ Ö·£º ³£Æ½ÕòÑØºÓ¶«¶þ·20ºÅ
ÓÊ ±à£º 523560
Ö÷ Ò³£º http://www.dgfupeng.com

¸Ã³§ÉÌÏà¹Ø²úÆ·£º
  • ÅçÂë»úרÓÃҺλ¼Æ
  •  
  • PP¸¡Çò
  •  
  • ½Ó½ü¿ª¹Ø
  •  
  • ²»Ðâ¸ÖË®Á÷¿ª¹Ø
  •  
  • ²»Ðâ¸Ö¸¡Çò
  •  
  • ¸É»É¹Ü
  •  
  • PPҺλ¿ª¹Ø ¸¡Çò¿ª¹Ø
  •  
  • ²»Ðâ¸ÖҺλ¿ª¹Ø
  •  
  • ¸¡Çò¿ª¹Ø
  •  
  • ¸ßѹ¼ÌµçÆ÷
  •  
    ¸ü¶à²úÆ·...