CM 8350P/CM 8350EP CDMA2000 EVDO 3G DTU
¼¼ Êõ ¹æ ·¶
 
Ò»¡¢²úÆ·¸ÅÊö
CM 8350P/CM 8350EP CDMA2000 EVDO 3G DTU²ÉÓÃARM9¸ßÐÔÄܹ¤Òµ¼¶Ç¶Èëʽ´¦ÀíÆ÷£¬ÒÔʵʱ²Ù×÷ϵͳRTOSΪÈí¼þÖ§³Åƽ̨,³¬´óÄÚ´æ,ÄÚǶÍêÉÆ×ÔÖ÷֪ʶ²úȨµÄTCP/IPЭÒéÕ»¡£ÎªÓû§Ìṩ¸ßËÙ¡¢°²È«¡¢Îȶ¨¿É¿¿´«Ê䷽ʽ£¬Êý¾ÝÖÕ¶ËÓÀÔ¶ÔÚÏߣ»Ö§³Ö¸ß°²È«¶àÖÖЭÒéת»»µÄÐéÄâרÓÃÍøÂç¡£Õë¶ÔÍøÂçÁ÷Á¿¿ØÖƵÄÓû§£¬²úÆ·Ö§³ÖÓïÒô£¬¶ÌÐÅ£¬Êý¾Ý´¥·¢ÉÏÏßÒÔ¼°³¬Ê±×Ô¶¯¶ÏÏߵŦÄÜ¡£Í¬Ê±Ò²Ö§³ÖË«Êý¾ÝÖÐÐı¸·Ý£¬ÒÔ¼°¶àÊý¾ÝÖÐÐÄͬ²½½ÓÊÕÊý¾ÝµÈ¹¦ÄÜ¡£¹«Ë¾²úÆ·Òѹ㷺ӦÓÃÓÚµçÁ¦£¬½ðÈÚ£¬Ë®Àû£¬»·±££¬ÓÊÕþ£¬ÆøÏóµÈÐÐÒµ¡£
 
¶þ¡¢           3G DTUÎÞÏß²ÎÊý
1.        ¼æÈÝIS-95 A/B, IS-2000 and 1XEV-DO(Revision 0 and A)
2.        Transmit / Receive Frequency Interval:45MHz for Cellular and 80MHz for PCS
3.        Transmit Frequency Range£º
821.04          848.97 MHz for Cellular and 1851.25 ~ 1908.75MHz for PCS
4.        Receive Frequency Range£º
869.04          893.97 MHz for Cellular and  1931.25 ~ 1988.75MHz for PCS
5.        Number of Channel 832 for Cellular and 42 for PCS
6.        Frequency Stability ¡À300Hz for Cellular and ¡À150Hz for PCS
7.        Êý¾ÝËÙÂÊ EVDO
Downlink (up to 3.1Mbps)
Uplink (up to 1.8Mbps)
 
Èý¡¢           3G DTUÓ²¼þϵͳ
1.      CPU£º¹¤Òµ¼¶¸ßÐÔÄÜARM9ǶÈëʽ´¦ÀíÆ÷£¬´øÄÚ´æ¹ÜÀíMMU,200MPS, 16KB Dcache,16KB Icache
2.      FLASH£º8MB£¬¿ÉÀ©³äµ½32MB
3.      SDRAM£º64MB£¬¿ÉÀ©³äµ½256MB
4.      ½Ó¿Ú£º
UART:
CM 8350P:
1¸öRS232´®¿Ú
´®¿ÚËÙÂÊ£º    110bps ~ 230400bps
Êý¾Ýλ֧³Ö£º  8λ »ò 7λ
ÆæÅ¼Ð£Ñéλ£º  ÎÞ »ò ÆæÊýУÑé »ò żÊýУÑé
Í£  Ö¹  Î»£º  1λ »ò 2λ
Á÷      ¿Ø£º  ÎÞ »ò RTS/CTS
CM 8350EP£º
1¸öRS485½Ó¿Ú£¨¸ù¾ÝÐèÒª£¬¿ÉÓ²¼þÌøÏßÖ§³ÖRS232/422/TTL£©
´®¿ÚËÙÂÊ£º    110bps ~ 230400bps
Êý¾Ýλ֧³Ö£º  8λ »ò 7λ
ÆæÅ¼Ð£Ñéλ£º  ÎÞ »ò ÆæÊýУÑé »ò żÊýУÑé
Í£ Ö¹ λ£º    1λ »ò 2λ
Á÷    ¿Ø£º    ÎÞ »ò RTS/CTS
              ¿ØÖƿڣº
              RS-232, 115200 bps, 8 data bits,1 stop bit, no parity (8N1)
       ָʾµÆ£º¾ßÓеçÔ´¡¢Í¨Ðż°ÔÚÏßָʾµÆ
       ÌìÏß½Ó¿Ú£º±ê×¼SMAÒõÍ·ÌìÏß½Ó¿Ú£¬ÌØÐÔ×迹50Å·
       UIM¿¨½Ó¿Ú£º3V/1.8V±ê×¼µÄÍÆ¸ËʽÓû§¿¨½Ó¿Ú
       µçÔ´½Ó¿Ú£º±ê×¼µÄ3о»ð³µÍ·µçÔ´²å×ù
       ÓïÒô½Ó¿Ú£º±ê×¼µÄ¶ú»úÂó¿Ë·ç½Ó¿Ú
5.      ¹©µç£º
Íâ½ÓµçÔ´£ºDC 9V 500mA
¿íµçѹ¹©µç£ºDC 5-32V
ͨÐŵçÁ÷£º350mA
´ý»úµçÁ÷£º35mA
6.      ³ß´ç£º
²úÆ·ÍâÐγߴ磺92x62x22 mm£¨²»°üÀ¨ÌìÏß¼°¹Ì¶¨¼þ£©
       ²úÆ·°ü×°³ß´ç£º298x226x60mm
7. ÖØÁ¿
0.41KG
8. ÆäËû²ÎÊý:
¹¤×÷»·¾³Î¶ȣº -25~+65ºC
´¢´æÎ¶ȣº -40~+85ºC
Ïà¶Ôʪ¶È£º 95%(ÎÞÄý½á)
ËÄ¡¢          3G DTU Èí¼þ¹¦ÄÜ
1.        TCP/UDP͸Ã÷Êý¾Ý´«Ê䣻֧³Ö¶àÖÖ¹¤×÷ģʽ£»ÐÄÌø°ü¼¼Êõ
2.        ÖÇÄÜ·ÀµôÏߣ¬Ö§³ÖÔÚÏß¼ì²â£¬ÔÚÏßά³Ö£¬µôÏß×Ô¶¯Öز¦£¬È·±£É豸ÓÀÔ¶ÔÚÏß
3.        Ö§³ÖRSA£¬RC4¼ÓÃÜËã·¨
4.        Ö§³ÖÐéÄâÖµÊØVWM£¨Virtual Man Watch£©¹¦ÄÜ£¬È·±£ÏµÍ³Îȶ¨¿É¿¿
5.        Ö§³ÖÐéÄâÊý¾ÝרÓÃÍø£¨APN/VPDN£©
6.        Ö§³ÖÊý¾ÝÖÐÐĶ¯Ì¬ÓòÃûºÍIPµØÖ··ÃÎÊ
7.        Ö§³ÖDNS¶¯Ì¬»ñÈ¡£¬·ÀÖ¹DNS·þÎñÆ÷Òì³£µ¼ÖµÄÉ豸µ±»ú
8.        Ö§³ÖË«Êý¾ÝÖÐÐı¸·Ý
9.        Ö§³Ö¶àÊý¾ÝÖÐÐÄͬʱ½ÓÊÜÊý¾Ý
10.    Ö§³Ö¶ÌÐÅ¡¢ÓïÒô¡¢Êý¾ÝµÈ»½ÐÑ·½Ê½ÒÔ¼°³¬Ê±¶Ï¿ªÍøÂçÁ¬½Ó
11.    Ö§³Ö¶ÌÏûÏ¢±¸·Ý¼°¸æ¾¯
12.    ¶àÖØÈíÓ²¼þ¿´ÃŹ·
13.    Êý¾Ý°ü´«Êä״̬±¨¸æ
14.    ±ê×¼µÄATÃüÁî½çÃæ
15.  ¿ÉÒÔÓÃ×öÆÕͨ²¦ºÅMODEM
16.  Ö§³Ötelnet¹¦ÄÜ
17.  Ö§³ÖÔ¶³ÌÅäÖã¬Ô¶³Ì¿ØÖÆ
18.  ͨ¹ý´®¿ÚÈí¼þÉý¼¶
19.  ͬʱ֧³ÖLINUX¡¢UNIXºÍWINDOWS²Ù×÷ϵͳ
 
Îå¡¢          3G DTU ²úÆ·ÌØÐÔ
1¡¢  ϵͳºÍ3GÎÞÏßÄ£¿é¼ä²ÉÓÃUSB2.0½Ó¿Ú£¬×ÜÏßËÙ¶È¿ÉÒÔ´ïµ½480M£¬½â¾öÁËÒµÄڴ󲿷ֳ§¼ÒϵͳºÍ3GÎÞÏßÄ£¿éÖ®¼ä²ÉÓÃRS232µÄ½Ó¿Ú£¬ÒòRS232´«ÊäËٶȲ»¹»¿ì£¬¿ìËÙ´«ËÍ3GµÄ½ÓÊÕµÄÊý¾Ý¶øµ¼ÖÂÊý¾Ý¶ªÊ§ÎÊÌâ¡£
2¡¢  Èý²ãϵͳ±£»¤£º       ÔÚÔ­À´Á½¼¶£¨Èí¼þ±£»¤+CPUÄÚÖÿ´ÃŹ·±£»¤£¬ÍâÖÃÓ²¼þ¿´ÃŹ·±£»¤£©ÏµÍ³±£»¤µÄ»ù´¡ÉÏ£¬Ôö¼ÓÒ»¼¶ÏµÍ³¼à²â±£»¤SWP£¨System Watch Protect£©£¬³¹µ×½â¾öÁËÒµÄÚ¡°¼ÙÔÚÏß¡±£¬¡°¼ÙËÀ»ú¡±£¬¡°µ±»ú¡±µÈÒÉÄÑÎÊÌâ¡£
3¡¢  ³¬´ó»º´æ£º¿ÉÒÔÌṩ16MµÄ¿Í»§´«ÊäÊý¾Ý»º´æ£¬½â¾öÒòÍøÂçÆ¿¾±µ¼ÖµÄÊý¾Ý¶ªÊ§»òÖØ´«£¬¼«´óÌá¸ß´«ÊäЧÂÊ£¬½ÚÊ¡¿Í»§¿ªÖ§¡£
4¡¢  ¸ßËÙ´¦ÀíCPU£º      ²ÉÓü«¸ßËÙARM9µÄ¹¤Òµ¼¶CPU£¬¿ÉÒÔ¸ü¼Ó¸ßËٵش¦Àí¸÷ÖÖЭÒéÊý¾Ýת»»£¬¹æ±ÜÒòCPU´¦ÀíËÙ¶ÈÂý¶øµ¼ÖµÄÊý¾ÝÖØ´«ºÍ¶ªÊ§µÈÎÊÌâ
5¡¢  DNS×Ô¶¯»ñÈ¡£º×Ô¶¯»ñÈ¡DNS£¬²»ÔÙÐèÒªÈ˹¤ÅäÖÃÊäÈëDNS£¬¹æ±ÜÁËÒòΪѡÔñµÄDNS·þÎñÆ÷Òì³££¬µ¼ÖÂDTUÉ豸µ±»úµÄÑÏÖØÏÖÏó¡£
6¡¢  ÍêÉÆµÄЭÒéÕ»£º       ϵͳ¼ÓÔØÁËÍêÉÆµÄTCP/IPЭÒéÕ»£¬²»ÏñÏÖÓдóÁ¿³§¼Ò²ÉÓõÄÊÇÇáÁ¿¼¶TCP/IP(LPIP)ЭÒéÕ»£¬Ð­ÒéÕ»ÊÇÓвüôµÄ£¬ÎÒ˾ϵͳ²ÉÓÃÁËÍêÉÆµÄTCP/IPЭÒéÕ»£¬ÍøÂçͨÐÅÐÔÄÜÓÅÒì¡£
7¡¢  EMCÐÔÄÜÓÅÒ죺ͨ¹ýµçÁ¦3000Vµç»÷²âÊÔ£¬ÌرðÊʺÏÔÚ¹¤ÒµÁìÓò»·¾³¶ñÁÓÏÂʹÓã¬ÏµÍ³Îȶ¨¿É¿¿¡£
8¡¢  Ö§³Ö¶àÖÐÐÄ£º¿Í»§Êý¾Ý¿ÉÒÔͬʱÍù¿Í»§Ö¸¶¨µÄ¼à¿ØÖÐÐÄ·¢ËÍ£¬×î´óÖ§³Ö·¢ËÍÖÐÐÄ´ï256¸ö¡£
9¡¢  RTUÈ«ÃæÖ§³Ö£ºÎÒ˾É豸ÔÚÊý¾Ýλ¡¢Í£Ö¹Î»¡¢Ð£Ñéλ¡¢Á÷¿ØÉÏ£¬ÄÜÈ«ÃæÖ§³ÖÒµÄÚµÄËùÓÐÐͺŵÄRTU.½â¾öÁËÒµÄÚ´óÁ¿³§¼ÒÎÞ·¨Ö§³Ö7λÊý¾ÝºÍ2λֹͣλµÄÎÊÌâ¡£
 
 


 

Áù¡¢           3G DTUµäÐÍÓ¦ÓÃ
1. µçÁ¦¼à¿Ø
2. ÓÍÌï¼à²â
3. Ô¶³Ì³­±í
4. ·µÆ¼à¿Ø
5. »·¾³¼à²â
6. ÆøÏó¼à²â
7. Ë®Àû¼à²â
8. ÈÈÍø¼à²â
9. µç±í¼à²â
10. »ú·¿¼à¿Ø
11. ½»Í¨Ö¸Ê¾
12. ú̿¼à¿Ø
13. µØÕð¼à²â
14. ³µÁ¾ÓÕµ¼
15. ¹©Ë®¼à¿Ø
16. ¸ßËÙ¹«Â·¼à²â
17. ÔëÉùʵʱ¼à¿Ø
18. »·±£ÖصãÎÛȾԴ¼à¿Ø
19. ¹©Ë®¹ÜÍøÊµÊ±´«Êä¼à¿Ø
20. µçÁ¦ÅäÍø×Ô¶¯»¯Ò£¿ØÏµÍ³
21. ¸÷Àà¹úÄÚÍâ´ø´®¿Ú»ò485½Ó¿ÚµÄPLC£¬RTUʵÏÖÎÞÏßÊý¾Ý´«ÊäµÈ
 


¹«Ë¾¼ò½é
²úƷĿ¼
¹©Ó¦ÐÅÏ¢

¹«Ë¾Ãû³Æ£º ÏÃÃŲÅïͨÐſƼ¼ÓÐÏÞ¹«Ë¾
µç »°£º 0592 5902655 / ÏÃÃŲÅï
ÊÖ»ú£º
µØ Ö·£º ÏÃÃÅÊÐÈí¼þÔ°2ÆÚÍûº£Â·37ºÅ2Â¥
ÓÊ ±à£º 361009
Ö÷ Ò³£º http://www.caimore.com

¸Ã³§ÉÌÏà¹Ø²úÆ·£º
  • ÏÃÃŲÅïÉÌÒµ¼¶WIFI·ÓÉÆ÷¼¼Êõ²ÎÊý
  •  
  • ÏÃÃŲÅ﹤ҵ¼¶2G/3G/4G+WIFI·ÓÉÆ÷¼¼Êõ²ÎÊý
  •  
  • ÏÃÃŲÅï3G/4G±êÇå°æÎÞÏßÊÓÆµ¼à¿ØÖն˼¼Êõ²ÎÊý
  •  
  • ÏÃÃŲÅïCM550-5XX ÎÞÏßRTU¼¼Êõ²ÎÊý
  •  
  • ÏÃÃŲÅïWIFIÍø¹ØÔËÓª¹ÜÀí·þÎñÆ÷
  •  
  • ÏÃÃŲÅï³µÔØ3G/4G+WiFi·ÓÉÆ÷
  •  
  • CM3181 GPRS DTUÎÞÏßÊý¾Ý´«ÊäÖÕ¶Ë
  •  
  • ²ÅïͨÐŵ¥¿ÚLTE 4G·ÓÉÆ÷
  •  
  • ÏÃÃŲÅ﹤ҵ¼¶5¿ÚLTE 4GÍø¹ØCM8551G
  •  
  • ZIGBEE RTU²É¼¯ÖÕ¶ËCM5592
  •  
    ¸ü¶à²úÆ·...
      ¹ØÓÚÎÒÃÇ | ÁªÏµÎÒÃÇ | ¹ã¸æ·þÎñ | ±¾Õ¾¶¯Ì¬ | ÓÑÇéÁ´½Ó | ·¨ÂÉÉùÃ÷ | ·Ç·¨ºÍ²»Á¼ÐÅÏ¢¾Ù±¨  
    ¹¤¿ØÍø¿Í·þÈÈÏߣº0755-86369299
    °æÈ¨ËùÓÐ ¹¤¿ØÍø Copyright@ Gkong.com, All Rights Reserved