Ò»¡¢²úÆ·¼ò½é
ÏÃÃŲÅ﹤ҵ¼¶LTE 4G·ÓÉÆ÷£¬ÐͺÅ:CM8560R£¬ÊÇÒ»¿î¹¤Òµ¼¶Éè¼Æ£¬²ÉÓÃLTE 4GÍøÂ磨֧³ÖTDDƵ¶ÎºÍFDDƵ¶Î£©£¬Ö§³ÖÒƶ¯M2M¹¦ÄÜ£¬Ö§³ÖµçÐÅM2M¹¦ÄÜ£¬´ø1¸öÒÔÌ«Íø¿Ú£¬1¸öRS232½Ó¿Ú£¬1¸öRS485½Ó¿ÚÒÔ¼°¶à·´ø¹âµç¸ôÀë¿ÉÉèÖõÄÊäÈëÊä³öGPIO¹¦Äܵĸ߶ËÎïÁªÍøÎÞÏß·ÓÉÆ÷¡£
É豸²ÉÓøßÐÔÄܵĹ¤Òµ¼¶400MHzÖ÷ƵµÄARM9ͨÐÅ´¦ÀíÆ÷£¬ÒÔǶÈëʽʵʱ²Ù×÷ϵͳΪÈí¼þÖ§³Åƽ̨£¬ÏµÍ³¼¯³ÉÁËȫϵÁдÓÂß¼Á´Â·²ãµ½Ó¦ÓòãͨÐÅÐÒ飬֧³ÖVPN£¨°üÀ¨PPTP+L2TP+MPPEºÍIPSEC+GRE£©,IPTABLE·À»ðǽ£¬¾²Ì¬¼°¶¯Ì¬Â·ÓÉ£¬PPP server¼°PPP client£¬,DHCP server¼°DHCP client£¬DDNS£¬·À»ðǽ£¬SNAT/DNAT£¬DMZÖ÷»ú,WEBÅäÖã¬Ö§³ÖAPN/VPDN£¬Ö§³ÖÉϵç×Ô¶¯²¦ºÅ£¬×Ô¶¯Î¬»¤Í¨ÐÅÁ´Â·£¬±£Ö¤Á´Â·ÓÀÔ¶ÔÚÏߣ¬Ö§³Ö×Ô¶¯¶¨Ê±ÉÏÏߺÍÏÂÏß¹¦Äܵȹ¦ÄÜ¡£
²úÆ·ÓµÓÐά»¤ÏµÍ³Îȶ¨µÄרÀû¼¼Êõ£¬È·±£É豸ÓÀÔ¶ÔÚÏߣ»²úÆ·Õû»ú²ÉÓýðÊôÍâ¿Ç£¬¿¹¸ÉÈÅ·À·øÉ䣬Ӳ¼þÉϲÉÓù¤Òµ¼¶Éè¼Æ£»ÏµÍ³´øÓп´ÃŹ·WDT±£»¤£¬ÁíÍâ¼ÓÔØÁËϵͳ¼à²â±£»¤SWP£¨System Watch Protect£©£»Õû»ú²úƷͨ¹ýÅ·ÖÞCEÈÏÖ¤£¬Í¨¹ýÖмìËù²âÊÔ£¬Í¨¹ýµçÁ¦3000Vµç»÷²âÊÔ£¬ËùÓÐÎÞÏßÄ£¿é¶¼ÓÐͨ¹ýCGDÈÏÖ¤»òÕßFCCÈÏÖ¤»òÕßCEÈÏÖ¤£»¾¹ýÑϸñµÄÉè¼Æ¡¢²âÊÔºÍ8ÄêµÄʵ¼ÊÓ¦Ó㬲úÆ·ÐÔÄÜÎȶ¨¿É¿¿¡£
²úƷͨ¹ýµçÐÅM2Mƽ̨½ÓÈë²âÊÔ£¬Òƶ¯M2Mƽ̨½ÓÈë²âÊÔ¡£
±¾²úÆ·Òѹ㷺ӦÓÃÓÚ½ðÈÚ£¬½»Í¨£¬¼à¿Ø£¬Ë®Àû£¬»·±££¬µçÁ¦£¬ÓÊÕþ£¬ÆøÏó¡¢Òƶ¯ÎïÁªÍøÒÔ¼°µçÐÅÎïÁªÍøµÈÐÐÒµ¡£
²úÆ·½Ó¿Úͼ£º
²úÆ·Åä¼þͼƬ£º
¶þ¡¢²úÆ·ÌØÐÔ
¹¤Òµ¼¶Éè¼Æ
- ¹¤Òµ¼¶ÎÞÏßÄ£¿é£º²ÉÓù¤Òµ¼¶ÎÞÏßÄ£¿é£¬¿¹¸ÉÈÅÇ¿£¬´«ÊäÎȶ¨¡£
- ʵʱ²Ù×÷ϵͳ£º²ÉÓÃLINUX2.6²Ù×÷ϵͳ£¬ÊµÊ±ÐÔÇ¿£¬¹¦ÄÜÉý¼¶¿ì£¬ÏµÍ³Îȶ¨£¬´øÍêÉÆTCP/IPÐÒéÕ»£»
- Ç¿»¯µç·°å£ºPCB²ÉÓÃ×ñÑ20HºÍ3WÔÔò£¬Í¬Ê±¹«Ë¾ËùÓвúÆ·µç·°å¶¼²ÉÓøßÆ·ÖʲÄÖÊÀ´Éú²ú£¬È·±£°å²ÄµÄÎȶ¨¿É¿¿¡£
- ¹¤Òµ¼¶ÔªÆ÷¼þ£ºÕû»úÔªÆ÷¼þ²ÉÓÃÑϸñɸѡµÄ¹¤Òµ¼¶ÔªÆ÷¼þÀ´Éú²ú¡£
- ¹¤Òµ¼¶µçÔ´£º¿íѹµçÔ´Éè¼Æ£¬µçÔ´ÊÊÓ¦·¶Î§ÎªDC5V~DC35V£¬ÄÚÖõçÔ´·´Ïò±£»¤ºÍ¹ýѹ¹ýÁ÷±£»¤¡£
- µç´Å·À»¤£ºÒÔÌ«Íø½Ó¿ÚÄÚÖÃ1.5KVµç´Å¸ôÀë·À»¤
- ¿¹¸ÉÈÅÉè¼Æ£º²ÉÓýðÊôÍâ¿Ç£¬ÆÁ±Îµç´Å¸ÉÈÅ£¬ÏµÍ³±£»¤µÈ¼¶IP30£»ÌìÏß´ø·ÀÀ×Éè¼Æ£»ÏµÍ³³¬µÍκͳ¬¸ßÎÂÉè¼Æ£»ÌرðÊʺÏÔÚ»·¾³¶ñÁӵĹ¤Òµ»·¾³ÏÂʹÓá£
Îȶ¨¿É¿¿
- ÔÚÏßά³ÖרÀû¼¼Êõ£ºÖÇÄÜ·ÀµôÏߣ¬ÔÚÏß¼ì²â£¬ÔÚÏßά³Ö£¬µôÏß×Ô¶¯Öز¦£¬Òì³£×Ô¶¯¸´Î»£¬È·±£É豸ÓÀÔ¶ÔÚÏß
- Èý²ãϵͳ±£»¤£ºÔÚÔÀ´Á½¼¶£¨Èí¼þ±£»¤+CPUÄÚÖÿ´ÃŹ·WDT±£»¤£©ÏµÍ³±£»¤µÄ»ù´¡ÉÏ£¬Ôö¼ÓÒ»¼¶ÏµÍ³ÐéÄâÖµÊØVWM£¨Virtual Man Watch£©¼ì²â±£»¤¹¦ÄÜ£¬ÍøÂçÒì³£¡¢»òÕßϵͳÊÕµ½Ç¿¸ÉÈÅÒ쳣ʱ£¬ÏµÍ³»áÖØг¹µ×¸´Î»£¬Ï൱ÓÚά»¤ÈËÔ±ÉÏÃŰε磬³¹µ×½â¾öÁËÒµÄÚϵͳÒì³£ÊÇÐèÒªÉÏÃŰεçµÄÂé·³£¬±£Ö¤ÏµÍ³Îȶ¨¿É¿¿
- UIM/SIM¿¨ESD±£»¤£º1.8V/3V/5V±ê×¼µÄÍƸËʽÓû§¿¨½Ó¿Ú£¬ÄÚÖÃ15KV ESD±£»¤¡£
- ´®¿ÚESD±£»¤£º´®¿ÚRS232ÄÚÖÃ15KV ESD±£»¤¡£
- ½ðÊôÍâ¿Ç£º²ÉÓýðÊôÍâ¿Ç£¬·À·øÉ䣬¿¹¸ÉÈÅ£»Íâ¿ÇºÍϵͳ°²È«¸ôÀ룬·ÀÀ×Éè¼Æ£»·ûºÏµçÁ¦°²¹æÒªÇó£»·À»¤µÈ¼¶ÎªIP41£»ÌرðÊʺÏÓÚ»·¾³¶ñÁӵĹ¤Òµ¿ØÖÆÁìÓò¡£
- ËùÓÐÎÞÏßÄ£¿é¶¼ÓÐͨ¹ýCGDÈÏÖ¤»òÕßFCCÈÏÖ¤»òÕßCEÈÏÖ¤¡£
- ¹¤Òµ¼¶CPU£º¹¤Òµ¼¶ARM9¸ßÐÔÄÜǶÈëʽ´¦Àí£¬400MHz£»´ø 16KB Dcache£¬¸ßËÙ»º´æÊý¾Ý£¬¼Ó¿ì¸ßËÙÊý¾Ý·ÃÎÊËٶȣ»´ø16KB Icache£¬¸ßËÙÖ¸Á´æ£¬¼ÓÇ¿ÁËÖ¸Áî´¦ÀíËÙ¶È, ´øÄÚ´æ¹ÜÀíµ¥ÔªMMU,ÅäºÏ²Ù×÷ϵͳ£¬¿ÉÒÔ·ÀÖ¹ÄÚ´æÒç³öµ¼ÖµÄËÀ»úÎÊÌâ¡£
- ³¬´óÄڴ棺FLASH64Mbits£¬SDRAM£¬256Mbits£¬Óг¬´óµÄÄÚ´æÀ´»º´æ¿Í»§·¢ËÍÊý¾Ý£¬Í¬Ê±½ÓÊÕ³¬´óÊý¾Ý°ü£¬Êý¾Ý²»¶ªÊ§¡£
- ÍêÉƵÄÐÒéÕ»£ºÐÂϵͳ¼ÓÔØÁËÍêÉƵÄTCP/IPÐÒéÕ»£¬²ÉÓÃÁËÍêÉƵÄTCP/IPÐÒéÕ»£»Ê¹ÍøÂçͨÐÅÐÔÄÜÓÅÒ죬µôÏ߸ÅÂʼ«´ó½µµÍ¡£
- EMCÐÔÄÜÓÅÒ죺ͨ¹ýÅ·ÖÞCEÈÏÖ¤£¬Í¨¹ýÖмìËù²âÊÔ£¬Í¨¹ýEMC²âÊÔ£»Í¨¹ýµçÁ¦3000Vµç»÷²âÊÔ£¬ÌرðÊʺÏÔÚ¹¤ÒµÁìÓò»·¾³¶ñÁÓÏÂʹÓã»ÏµÍ³EMC/EMIÓÅÒ죬ϵͳÎȶ¨¿É¿¿£»
¹¦ÄÜÇ¿´ó
- Ö§³ÖÒÔÌ«ÍøÊý¾ÝͨÐźÍ·ÓÉת·¢
- Ö§³Ö´®¿ÚTCP/UDP͸Ã÷Êý¾Ý´«Êä»òÕß´®¿ÚÅäÖã¨DTU¹¦ÄÜ£©
- Ö§³ÖRS485½Ó¿ÚTCP/UDP͸Ã÷Êý¾Ý´«Êä
- Ö§³ÖVPN°²È«ËíµÀ¹¦ÄÜ,°üÀ¨PPTP¡¢MPPE¡¢L2TP¡¢GREºÍIPSEC
- ÖÇÄÜ·ÀµôÏߣ¬Ö§³ÖÔÚÏß¼ì²â£¬ÔÚÏßά³Ö£¬µôÏß×Ô¶¯Öز¦£¬È·±£É豸ÓÀÔ¶ÔÚÏß
- Ö§³ÖIPTABLES·À»ðǽ£¬°ü¹ýÂ˹¦ÄÜ
- Ö§³Ö¶¨Ê±ÉÏÏßÏÂÏß¹¦ÄÜ£¬¿ÉÒÔÉèÖÃÉ豸ÔÚij¶Îʱ¼äÄÚÉÏÏߺÍij¸öʱ¼äÄÚÏÂÏß
- Ö§³Ö¶¯Ì¬Â·Óɺ;²Ì¬Â·ÓÉ¡¢RIPv1¡¢RIPv2¡¢OSPF¡¢BGP¡¢NDSP¡¢IRMP¡¢SNSP¡¢IGMP¡¢DVMRP¡¢PIM-SM/DM
- Ö§³Ö¶àÖÖÐÒ飺TCP/IP£¬UDP£¬ICMP£¬SMTP£¬HTTP£¬POP3£¬OICQ£¬TELNET£¬FTPµÈ¡£
- Ö§³Ö¶¯Ì¬Â·Óɺ;²Ì¬Â·ÓÉ
- Ö§³ÖDHCP/DHCPD¹¦ÄÜ
- Ö§³Ö¶Ë¿ÚÓ³ÉäNAT¹¦ÄÜ£¬ÈçSNAT£¬DNAT
- Ö§³Ö¶¯Ì¬DDNS£ºÖ§³Ö»¨Éú¿Ç¡¢88IPºÍdyndnsÓòÃû·þÎñÉÌ
- Ö§³ÖDMZÖ÷»ú
- Ö§³ÖAPN/VPDNÍøÂç
- Ö§³Ö´ø¿í¹ÜÀí
- ·½±ãµÄWEBÅäÖã¬Ö§³ÖÔ¶³ÌWEB¹ÜÀí
- Ö§³ÖWEBÅäÖñ£´æºÍ»Ö¸´£¬ÊµÏÖ²ÎÊýµÄ±¸·ÝºÍÅúÁ¿É豸µÄ¿ìËÙÅäÖÃ
- Ö§³Ötelnet¹ÜÀí£¬·½±ãÒ×ÓõĿØÖÆ̨shell½»»¥»·¾³
- Ö§³Ö¶ą̀Öն˹²Ïírouter ppp¹ãÓòÍø³ö¿Ú
- Ö§³Ö¶àÖÖÎÞÏß²¦ºÅ·½Ê½£º×Ô¶¯·ÖÅ䣬ָ¶¨IP£¬Ö¸¶¨±¾µØ¶Ô¶ËIP
- Ö§³Ö×÷ΪPPP·þÎñÆ÷£¬¶àÖÖÈÏÖ¤·½Ê½£¬Ö§³ÖË«ÏòÈÏÖ¤
- ·½±ãÒ×ÓõÄCOM¼°SYSLOGϵͳÕï¶Ï£¬µ÷ÊÔ¹¦ÄÜ
- Ö§³Ö´®¿Ú±¾µØÈí¼þÉý¼¶
- Ö§³ÖTFTPÈí¼þÔ¶³ÌÉý¼¶
- Ö§³ÖRTCʵʱʱÖÓ
- ͬʱ֧³ÖLINUXºÍWINDOWS²Ù×÷ϵͳ
¼òµ¥Ò×ÓÃ
- ²úÆ·³ö³§ÅäÖÃĬÈϲÎÊý£¬¿Í»§Ö»ÐèÐ޸ĸö±ð²ÎÊýÉõÖÁ²»ÐèÒª×öÈκβÎÊýÐ޸ģ¬¾Í¿ÉÒÔʵÏÖ¿ìËÙʹÓÃÉ豸¡£
- ͼÐλ¯ÅäÖù¤¾ß£ºÍêÉƵÄͼÐλ¯ÅäÖù¤¾ß£¬Ìṩ¿ìËÙÅäÖù¦ÄÜ£¬ÊµÏÖ¿Í»§¿ìËÙÅäÖã»ÌṩÅúÁ¿ÅäÖù¦ÄÜ£¬ÊµÏÖÅúÁ¿É豸µÄÅäÖá£
- ²úƷ˵Ã÷ÊéÌṩ¿ìËÙÅäÖÃ˵Ã÷£¬¿ÉÒÔ¿ìËÙʹÓÃÉ豸¡£
- ¼ì²éÈí¼þ£ºÌṩSYSLOGÈÕÖ¾Êä³ö¹¦ÄÜ£¬¿ÉÒÔÓÃÓڲο¼É豸¹¤×÷ÈÕÖ¾£¬Í¬Ê±ÐÖú·ÖÎöÒ쳣ʱµÄÔÒò£»Í¨¹ý´®¿Úµ÷ÊÔÈí¼þ£¬Ìṩ²»Í¬µÄµ÷ÊԵȼ¶Êä³ö£¬·½±ã¿Í»§²é¿´¸÷ÖÖÐÅÏ¢£¬¿ìËÙ¶¨Î»ÎÊÌâ¡£
- É豸¾¹ý8ÄêµÄ³Áµí£¬É豸¹¦ÄÜÍêÉÆͬʱ¼òµ¥Ò×Óá£
Èý¡¢¼¼Êõ²ÎÊý
ÎÞÏß²ÎÊý£º
씀|
ÄÚÈÝ
|
ÎÞÏßÄ£¿é
|
²ÉÓù¤Òµ¼¶ÎÞÏßÄ£¿é
|
±ê×¼¼°Æµ¶Î
£¨TDDƵ¶Î£©
|
LTE TDD: 2600/2300MHz
UMTS: 2100/900MHz
GSM: 850/900/1800/1900MHz
RxDiv Band:UMTS 2100/900MHz LTE TDD 2600/2300MHz
|
±ê×¼¼°Æµ¶Î
£¨FDDƵ¶Î£©
|
LTE FDD: 2600/2100/1800/DD800MHz
UMTS: 2100/900MHz
RxDiv Band:UMTS 2100/900MHz LTE FDD 2600/2100/1800/DD800MHz
|
±àÂë·½°¸
|
LTE/UMTS/HSPA+/HSDPA/HSUPA/WCDMA/EDGE/GSM
|
ͨÐÅ´ø¿í
( TDDƵ¶Î)
|
LET TDD:DL 68Mbps/UL 17Mbps
DC_HSPA+:DL 42Mb/s(Category 24)
HSPA+:DL 28Mb/s(Category 18)
HSdPA:DL 14.4Mb/s(Category 8)
HSUPA+:DL 5.76Mb/s(Category 6)
WCDMA CS:UL 64kbps/DL 64kbps
WCDMA PS:UL384kbps/DL384kbps
|
ͨÐÅ´ø¿í
£¨ FDDƵ¶Î£©
|
LET FDD:DL 100Mbps/UL 50Mbps
DC_HSPA+:DL 42Mb/s(Category 24)
HSPA+:DL 28Mb/s(Category 18)
HSdPA:DL 14.4Mb/s(Category 8)
HSUPA+:DL 5.76Mb/s(Category 6)
WCDMA CS:UL 64kbps/DL 64kbps
WCDMA PS:UL384kbps/DL384kbps
|
·¢É书ÂÊ
|
LET:23 dBm WCDMA/HSDPA:24dBm
|
½ÓÊÕÁéÃô¶È
|
<-109dBm
|
¹¦ÄÜÖ§³Ö
|
Ö§³ÖÊý¾Ý¡¢ÓïÒô¡¢¶ÌÐźʹ«Õæ
|
Ó²¼þϵͳ£º
씀|
ÄÚÈÝ
|
CPU
|
¹¤Òµ¼¶ARM9¸ßÐÔÄÜǶÈëʽ´¦Àí£»400MHz£»´ø 16KB Dcache,¸ßËÙ»º´æÊý¾Ý£¬¼Ó¿ì¸ßËÙÊý¾Ý·ÃÎÊËٶȣ»´ø16KB Icache£¬¸ßËÙÖ¸Á´æ£¬¼ÓÇ¿ÁËÖ¸Áî´¦ÀíËÙ¶È
|
MMU
|
CPU´øMMUÄÚ´æ¹ÜÀíµ¥Ôª£¬¿ÉÒÔ·ÀÖ¹ÄÚ´æÒç³öµ¼ÖÂϵͳµÄÒì³£
|
FLASH
|
64Mbits£¨¿ÉÀ©³äµ½256Mbits£©ÓÐ×ã¹»´óµÄÄÚ´æÀ´´æ·Å³ÌÐòºÍÊý¾Ý
|
SDRAM
|
256Mbits(¿ÉÀ©³äµ½2048Mbits)£¬ÓÐ×ã¹»´óµÄ»º´æÀ´Ìá¸ßϵͳÔËËãËÙ¶È
|
²Ù×÷ϵͳ£º
씀|
ÄÚÈÝ
|
²Ù×÷ϵͳ
|
²ÉÓÃLINUX2.6²Ù×÷ϵͳ£¬´øÄÚ´æ¹ÜÀíµ¥Ôª£¬ÊµÊ±ÐÔÇ¿£¬¹¦ÄÜÉý¼¶¿ì£¬ÏµÍ³Îȶ¨£»
|
½Ó¿ÚÀàÐÍ£º
씀|
ÄÚÈÝ
|
ÒÔÌ«Íø¿Ú
|
1¸ö 10/100 Base-T ÒÔÌ«Íø¿Ú£¬Ethernet IEEE 802-3, 802-2£»ÄÚÖÃ1.5KVµç´Å¸ôÀë±£»¤
|
´®¿Ú
|
1¸öRS232´®¿Ú»ò1¸öRS485½Ó¿Ú£¨¿ÉÖ§³ÖRS422/TTL£©
Êý¾Ýλ£º7¡¢8λ
ֹͣλ£º1¡¢2λ
УÑéλ£ºÎÞУÑé¡¢ÆæУÑ顢żУÑé¡¢SPACE¼°MARKУÑé
´®¿ÚËÙÂÊ£º110bps ~ 230400bps
Á÷¿Øλ£ºÎÞÁ÷¿Ø¡¢RTS/CTS Ó²Á÷¿Ø»òXON/XOFFÈíÁ÷¿Ø
|
RS485
|
1·RS485½Ó¿Ú£¬Ö§³ÖRS485ͨÐÅ
|
5·GPIO
|
5·´ø¹âµç¸ôÀëGPIO£¬¿ÉÒÔÉèÖóÉÊäÈë»òÕßÉèÖóÉÊäÈ룬ÒÔ¿ØÖÆÍâΧÉ豸£¬»òÕß¼ì²âÍâΧÉ豸״̬
|
ָʾµÆ
|
¾ßÓеçÔ´POWER,Á¬½ÓLink/ACT£¬Í¨ÐÅCOMM¼°ÔÚÏßָʾµÆOnline
|
ÌìÏß½Ó¿Ú
|
±ê×¼SMAÒõÍ·ÌìÏß½Ó¿Ú£¬ÌØÐÔ×迹50Å·£»¹«Ë¾¿ÉÒÔÑ¡Åä3M/5M/10M/15MµÄÌìÏßÑÓ³¤Ïߣ¬Âú×ã¿Í»§µÄ²»Í¬Ê¹Óó¡ºÏÐèÒª
|
UIM¿¨½Ó¿Ú
|
1.8V/3V/5V±ê×¼µÄÍƸËʽÓû§¿¨½Ó¿Ú£¬ÄÚÖÃ15KV ESD±£»¤
|
ÓïÒô½Ó¿Ú
|
±ê×¼µÄ¶ú»úÂó¿Ë·ç½Ó¿Ú£¨ÐèÒªÈí¼þÅäºÏ²ÅÄÜʹÓã©
|
µçÔ´½Ó¿Ú
|
±ê×¼µÄ3о»ð³µÍ·µçÔ´²å×ù
|
¹©µçÇé¿ö£º
씀|
ÄÚÈÝ
|
¹©µçµçѹ
|
¿íµçѹÉè¼Æ£¬DC 5Vµ½DC32VµçÔ´¶¼¿ÉÒÔÖ±½Ó¸øÉ豸¹©µç£»Í¬Ê±ÄÚÖõçÔ´·´Ïò±£»¤ºÍ¹ýѹ¹ýÁ÷±£»¤
|
±êÅäµçÔ´
|
DC9V/1.5A
|
ͨÐŵçÁ÷
|
ͨÐÅʱƽ¾ùµçÁ÷£º390mA@+9VDC;
µÇÍø˲¼ä·åÖµµçÁ÷£º1.0A@+9VDC
|
´ý»úµçÁ÷
|
´ý»úƽ¾ùµçÁ÷£º<56mA@+9VDC
|
ÎïÀíÌØÐÔ£º
씀|
ÄÚÈÝ
|
Íâ¿Ç
|
²ÉÓýðÊôÍâ¿Ç£¬·À·øÉ䣬¿¹¸ÉÈÅ£»Íâ¿ÇºÍϵͳ°²È«¸ôÀ룬·ÀÀ×Éè¼Æ£»·ûºÏµçÁ¦°²¹æÒªÇó£»·À»¤µÈ¼¶ÎªIP30£»ÌرðÊʺÏÓÚ»·¾³¶ñÁӵĹ¤Òµ¿ØÖÆÁìÓò
|
²úÆ·ÍâÐγߴç
|
155*96*23mm£¨²»°üÀ¨ÌìÏß¼°¹Ì¶¨¼þ£©
|
²úÆ·°ü×°³ß´ç
|
298x226x60mm
|
ÖØÁ¿
|
0.69kg
|
ÆäËû²ÎÊý£º
씀|
ÄÚÈÝ
|
¹¤×÷ζÈ
|
-30 ºC ~+70ºC
|
À©Õ¹¹¤×÷ζÈ
|
-35 ºC~+75ºC
|
´¢´æζÈ
|
-40~+85ºC
|
Ïà¶Ôʪ¶È
|
95%(ÎÞÄý½á)
|
ËÄ¡¢²úÆ·Ó¦ÓÃÁ´½Óͼ
1¡¢½ðÈÚ½»Ò×»ò½»Í¨¿ØÖÆÐÐÒµÓ¦ÓÃ
2¡¢ÊÓƵ¼à¿Ø»òÊÓƵ´«Êä
Îå¡¢µäÐÍÓ¦ÓÃ
µçÁ¦ÐÐÒµ
- µçÁ¦¼à¿Ø
- ·µÆ¼à¿Ø
- µç±í¼à²â
- »ú·¿¼à¿Ø
- µçÁ¦ÅäÍø×Ô¶¯»¯Ò£¿Øϵͳ
- Ô¶³Ì³±í
½»Í¨ÐÐÒµ
- ½»Í¨Ö¸Ê¾
- ³µÁ¾ÓÕµ¼
- ¸ßËÙ¹«Â·¼à²â
- ½»Í¨ºìÂ̵ƿØÖƺÍÅÄÕÕ´«Êä
Ë®ÀûÐÐÒµ
- Ë®Àû¼à²â
- ¹©Ë®¼à¿Ø
- ¹©Ë®¹ÜÍøʵʱ´«Êä¼à¿Ø
|
»·¾³¡¢ÆøÏó¡¢ÓÍÌïµÈÐÐÒµ
- »·±£ÖصãÎÛȾԴ¼à¿Ø
- »·¾³¼à²â
- ÆøÏó¼à²â
- ÔëÉùʵʱ¼à¿Ø
- ÓÍÌï¼à²â
- ÈÈÍø¼à²â
- ú̿¼à¿Ø
- µØÕð¼à²â
- ¸÷Àà¹úÄÚÍâ´ø´®¿Ú»ò485½Ó¿ÚµÄPLC£¬RTUʵÏÖÎÞÏßÊý¾Ý´«Êä
|
Áù¡¢¹«Ë¾×ÊÖÊ
ÄÚÈÝ
|
Çé¿öÖ¸±ê
|
¹«Ë¾ÈÙÓþ
|
2011Äê±»ÆÀΪ“Öйú¹¤¿ØÐÐÒµ¿Í»§ÂúÒâ×î¼Ñ¹©Ó¦ÉÌ”£»¹«Ë¾GPRS DTU²úÆ·±»ÆÀΪ“´´Ð²úÆ·½±”; 2012Ä깫˾³ÉΪ“ÖйúÖÊÁ¿ÍòÀïÐД»áÔ±¡£
|
¸ßпƼ¼ÆóÒµ
|
2010Äê±»¹ú¼ÒÈ϶¨µÄ¸ßпƼ¼ÆóÒµ
|
Ë«ÈíÆóÒµ
|
2010Äê±»¹ú¼ÒÈ϶¨µÄË«ÈíÆóÒµ
|
Öø×÷°æȨ
|
¹«Ë¾ÓµÓÐ1Ïî±£³ÖÉ豸Îȶ¨µÄרÀû¼¼ÊõÖ¤ÊéºÍ8¸öÈí¼þÖø×÷°æȨ֤Êé
|
°ìÊ´¦
|
È«¹úÉèÁ¢ÁË9´óÇøÓò°ìÊ´¦£¬·½±ãΪ¿Í»§Ìṩ½ü¾àÀëÌùÐÄ·þÎñ
|
×¢²á×ʱ¾
|
¹«Ë¾×¢²á×ʱ¾500Íò£»ÊÇÏÃÃÅÊÐÖصã·ö³Ö¸ßпƼ¼ÆóÒµ
|
ÀúÊ·³Áµí
|
11ÄêµÄÐÐÒµÑз¢»ýÀÛºÍÐÐÒµÓ¦Óÿ¼Ñé
|