Ê×Ò³ - ÐÂÎÅ - ÕÐƸ - ÏÂÔØ - ²úÆ· - ³§ÉÌ - ·½°¸ - ÎÄÕª - Çó¹º - Õ¹ÀÀ
Ãâ·Ñ×¢²á µÇ¼ | ¹ã¸æ·þÎñ | ¿Í·þÖÐÐÄ
Öлª¹¤¿ØÍø ¡ú ¹¤¿Ø²úÆ· ¡ú MOXA ¸ß¼¶ÎÞÏß AP/ÍøÇÅ/AP¿Í»§¶Ë AWK-6222 ϵÁÐ
²úÆ·Ãû³Æ£º MOXA ¸ß¼¶ÎÞÏß AP/ÍøÇÅ/AP¿Í»§¶Ë AWK-6222 ϵÁÐ
ÐÍ ºÅ£º
¼Û ¸ñ£º 0.00
Æ· ÅÆ£º
 
Êղش˲úÆ·     ²é¿´ÊÕ²Ø

AWK-6222ϵÁÐÊÒÍâ˫ƵÉäƵÎÞÏßAP/ÍøÇÅ/¿Í»§¶ËΪ¹Ø¼ü¹¤Òµ Ó¦Óû·¾³ÌṩÁËÁé»îµÄÎÞÏß½â¾ö·½°¸¡£AWK-6222ϵÁеĿíΠ²Ù×÷Éè¼Æ¸ß´ï-40~75¡æ£¬ÆäÖ§³ÖIP68µÈ¼¶µÄ·À³¾·ÀË®Éè¼Æ£¬±ã ÓÚÓû§ÔÚ½«ÏÖÓеÄÓÐÏßÍøÂçÀ©Õ¹µ½ÊÒÍâ»·¾³¡£

AWK-6222µÄÁ½¸ö¶ÀÁ¢ÉäƵģ¿éÖ§³Ö¸ü¹ã·ºµÄÎÞÏßÅäÖúÍÓ¦ Óã¬ÆäÈßÓàÎÞÏßÁ¬½ÓÄÜÁ¦Ìá¸ßÁËÕû¸öÎÞÏßÍøÂçµÄ¿É¿¿ÐÔ¡£AWK- 6222ϵÁл¹ÓÐÁ½¸öÈßÓàÖ±Á÷µçÔ´ÊäÈ룬Ìá¸ßÁ˹©µç¿É¿¿ÐÔ£¬Í¬ ʱ»¹Ö§³ÖÒÔÌ«Íø¹©µç£¨PoE£©£¬ÈÃÍøÂ繩µçÅäÖøüΪ¼ò±ã¡£

ÈßÓàÉè¼ÆÌá¸ßϵͳ¿É¿¿ÐÔ

  • Ë«Ö±Á÷µçÔ´ÊäÈëºÍÒÔÌ«Íø¹©µç
  • ÈßÓàµÄ˫ƵÉäƵÉè¼ÆʵÏÖ¿ìËÙÖ÷»ú¹ÊÕϻָ´
  • ±ÜÃâµç²¨¸ÉÈÅÔì³ÉµÄÁ¬½ÓÖжÏ
  • ÎÞÏßͨПºÔØƽºâ

Âú×ãÑÏ¿Á»·¾³µÄ¼á¹ÌÉè¼Æ

  • P68½ðÊô·â×°
  • ·ÀË®·À³¾Éè¼ÆµÄRJ45Á¬½ÓÆ÷
  • M12Á¬½ÓÆ÷±£»¤Õñ¶¯³å»÷
  • ÌØÊâ¼ÓÓ²µÄ°²×°¹¤¾ßÂú×ãÊÒÍâµÄÁé»î°²×°ÒªÇó

    ÎÞÏß¾ÖÓòÍø½Ó¿Ú ±ê×¼:
    IEEE 802.11a/g/b ÎÞÏßÍøÂçЭÒé
    IEEE 802.11i ÎÞÏß°²È«Ð­Òé
    IEEE 802.3u ÒÔÌ«ÍøÂçЭÒé
    IEEE 802.3af ÒÔÌ«Íø¹©µçЭÒé
    IEEE 802.1D Éú³ÉÊ÷ЭÒé
    IEEE 802.1w ¿ìËÙÉú³ÉÊ÷ЭÒé
    À©Æµµ÷ÖÆÓëËÙÂÊ ( µäÐͲúÆ·):
    ¡¤Ö§³Ö DBPSK£¬DQPSK£¬CCKµ÷ÖÆ·½Ê½µÄDSSS(Ö±½ÓÐòÁÐչƵ)
    ¡¤Ö§³ÖBPSK£¬QPSK£¬16QAM£¬64QAM µÄOFDM(Õý½»Æµ·Ö¸´
    ÓÃ)64QAM @ 54 Mbps£¬16QAM @ 24/36 Mbps£¬QPSK @ 12/18
    Mbps,CCK @ 11/5.5 Mbps£¬DQPSK @ 2 Mbps£¬DBPSK@ 1
    Mbps
    ¹¤×÷Ƶ¶Î( ÖÐÐÄƵÂÊ):
    ÃÀ¹ú:
    2.412 ~ 2.462 GHz (11Ƶ¶Î)
    5.18 ~5.24 GHz (4Ƶ¶Î)
    Å·ÃË:
    2.412 ~ 2.472 GHz (13 Ƶ¶Î)
    5.18 to 5.24 GHz (4Ƶ¶Î)
    °²È«ÐÔ:
    ¡¤SSID¹ã²¥¿ª±Õ¹¦ÄÜ
    ¡¤»ùÓÚMAC/IP/ ЭÒé/ ¶Ë¿Ú¹ýÂ˵ķÀ»ðǽ¼¼Êõ
    ¡¤64λºÍ128 λWEP¼ÓÃÜ£¬WPA /WPA2 ¸öÈË°æºÍÆóÒµ°æ
    (IEEE802.1X/RADIUS£¬TKIP ºÍ AES)
    Êý¾Ý´«ÊäËÙÂÊ:
    802.11b: 1£¬2£¬5.5£¬11 Mbps
    802.11a/g: 6£¬9£¬12£¬18£¬24£¬36£¬48£¬54 Mbps
    ·¢É书ÂÊ:
    802.11b: Typ. 23¡À1.5 dBm @ 1 to 11 Mbps
    802.11g: Typ. 18¡À1.5 dBm @ 6 to 24 Mbps£¬Typ. 16¡À1.5 dBm
    @ 36 to 48Mbps£¬Typ. 15¡À1.5 dBm @ 54 Mbps
    802.11a: Ty p. 20 ¡À 1.5 d B m @ 6 to 24 M b p s£¬Typ. 19 ¡À 1.5 d B m @ 36 M b p s£¬
    Ty p. 18 ¡À 1.5 d B m @ 48 M b p s£¬Typ. 17 ¡À 1.5 d B m @ 54 M b p s
    ½ÓÊÕÁéÃô¶È:
    802.11b: -97 dBm @ 1 Mbps£¬-94 dBm @ 2 Mbps£¬-92 dBm @ 5.5 Mbps£¬
    -90 dBm @ 11 Mbps
    802.11g: -93 dBm @ 6 Mbps£¬-91 dBm @ 9 Mbps£¬-90 dBm @ 12 Mbps£¬
    -88 dBm @ 18 Mbps£¬-84 dBm @ 24 Mbps£¬-80 dBm @ 36 Mbps£¬
    -76 dBm @ 48 Mbps£¬-74 dBm @ 54 Mbps
    802.11a: -90 dBm @ 6 Mbps£¬-89 dBm @ 9 Mbps£¬-89 dBm @ 12 Mbps£¬
    -85 dBm @ 18 Mbps£¬-83 dBm @ 24 Mbps£¬-79 dBm @ 36 Mbps£¬
    -75 dBm @ 48 Mbps£¬-74 dBm @ 54 Mbps
    ЭÒéÖ§³Ö
    Ò»°ãЭÒéÖ§³Ö: Proxy ARP£¬DNS£¬HTTP£¬HTTPS£¬IP£¬ICMP£¬
    SNTP£¬TCP£¬UDP£¬RADIUS£¬SNMP£¬RTP
    AP ЭÒéÖ§³Ö: ARP£¬BOOTP£¬DHCP£¬¶¯Ì¬VLAN-Tags
    £¨802.1X-Clients£©£¬STP/RSTP (IEEE 802.1D/w)
    ½Ó¿Ú ĬÈÏÌìÏß: 5 dBi£¬2.4 GHz È«ÏòÌìÏߣ¬N-type(male)
    À©Õ¹ÌìÏßÁ¬½Ó: N-type (female)
    ¾ÖÓòÍø¶Ë¿Ú: 2¸ö10/100BaseT(X) ×ÔÊÊÓ¦ (RJ45·ÀË®½Ó¿Ú)
    ¿ØÖƶ˿Ú: RS-232 (RJ45·ÀË®½Ó¿Ú)
    LEDָʾµÆ: PWR£¬FAULT£¬STATE£¬WLAN1£¬WLAN2£¬
    LAN1£¬LAN2
    ±¨¾¯´¥Í· ( Êý×ÖÊä³ö·½Ê½£¬M12 Á¬½ÓÆ÷): 1¸öÔØÁ÷¼ÌµçÊä³ö
    µçÈÝ£º1A @ 24 VDC
    Êý×ÖÊäÈ루M12 Á¬½ÓÆ÷): 2 ·µç¸ôÀëÊäÈë
    ¡¤+13 ~ +30 V ״̬¡°1¡±
    ¡¤+3 ~ -30 V ״̬¡°0¡±
    ¡¤×î´óÊäÈëµçÁ÷: 8 mA
    »úеÌØÐÔ ·â×°: IP68·À»¤µÈ¼¶£¬½ðÊô·â×°
    ÖØÁ¿: 1.8 kg
    ³ß´ç: 224 x 147.7 x 66.5 mm (8.82 x 5.82 x 2.62 Ó¢´ç)
    °²×°: ±Ú¹Ò°²×°(±ê×¼)¡¢DINµ¼¹ì°²×° (¿ÉÑ¡)¡¢¸Ëʽ°²×°£¨¿ÉÑ¡£©

    ¹¤×÷»·¾³
    ¹¤×÷ζÈ: -40 ~ 75¡æ(-40 ~ 167 ¡ãF)
    ´æ´¢Î¶È: -40 ~ 85¡æ(-40 ~ 185 ¡ãF)
    ¹¤×÷ʪ¶È: 5% ~ 95% ( ÎÞÄý¶)
    µçÔ´ÒªÇó ÊäÈëµçѹ: 12 ~ 48 VDC£¬ÈßÓàË«Ö±Á÷µçÔ´ÊäÈë»òÕß48 VDCÒÔÌ«
    Íø¹©µç ( ¼æÈÝIEEE 802.3af)
    Á¬½Ó·½Ê½: A-CodingµÄM12Á¬½ÓÆ÷
    Ìṩ·´½Ó±£»¤
    °²¹æÈÏÖ¤ °²È«ÈÏÖ¤: EN60950-1£¬UL60950-1
    ƵÂÊ: EN300 328£¬EN301 893
    µç´Å¼æÈÝ: EN301 489-1/-17£¬FCC Part 15
    ×¢Òâ: Çë¹Ø×¢moxa ¹«Ë¾ÍøÕ¾ÒÔ»ñµÃ×îÐÂÈÏ֤ͨ¹ýÇé¿ö.

    ±£ÐÞÆÚ
    5Äê
 


¹«Ë¾¼ò½é
²úƷĿ¼
¹©Ó¦ÐÅÏ¢

¹«Ë¾Ãû³Æ£º Ħɯ¹ú¼ÊóÒ×£¨ÉϺ££©ÓÐÏÞ¹«Ë¾
µç »°£º 021 52589955 / Íõ С ½ã
´« Õ棺 021-52585505
µØ Ö·£º ÉϺ£ÊÐÑÓ°²Î÷·1160ºÅÊ×ÐÅÒø¶¼¹ú¼Ê¹ã³¡18²ã
ÓÊ ±à£º 200052
Ö÷ Ò³£º http://www.moxa.com.cn

¸Ã³§ÉÌÏà¹Ø²úÆ·£º
  • moxa EDR-810ϵÁÐ
  •  
  • moxa MD-119ϵÁÐ º£ÊÂרÓÃÏÔʾÆ÷
  •  
  • moxa MXview2.3ÍøÂç¹ÜÀíÈí¼þ
  •  
  • moxa ioLogik R1241
  •  
  • ioLogik R1240
  •  
  • moxa ioLogik R1214
  •  
  • moxa ioLogik R1212
  •  
  • moxa ioLogik R1210
  •  
  • moxa IEX-402-VDSL2ϵÁÐ
  •  
  • moxa MGate™ 5102-PBM-PNϵÁÐ
  •  
    ¸ü¶à²úÆ·...