Ê×Ò³ - ÐÂÎÅ - ÕÐƸ - ÏÂÔØ - ²úÆ· - ³§ÉÌ - ·½°¸ - ÎÄÕª - Çó¹º - Õ¹ÀÀ
Ãâ·Ñ×¢²á µÇ¼ | ¹ã¸æ·þÎñ | ¿Í·þÖÐÐÄ
Öлª¹¤¿ØÍø ¡ú ¹¤¿Ø²úÆ· ¡ú IKS-G6524ϵÁÐ
²úÆ·Ãû³Æ£º IKS-G6524ϵÁÐ
ÐÍ ºÅ£º IKS-G6524
¼Û ¸ñ£º 0.00
Æ· ÅÆ£º Ħɯ
 
Êղش˲úÆ·     ²é¿´ÊÕ²Ø

¼ò½é

¹ý³Ì×Ô¶¯»¯ºÍ½»Í¨×Ô¶¯»¯ÐèÒªÕûºÏÊý¾Ý¡¢ÒôƵºÍÊÓƵÐÅÏ¢£¬ Òò´ËÐèÒª²úÆ·¾ß±¸¸ßÐÔÄܺ͸߿ɿ¿ÐÔ¡£IKS-G6524ϵÁÐÈ« ǧÕ׹Ǹɽ»»»»úÌṩ¶à´ï24¸öǧÕ×ÒÔÌ«Íø¿Ú£¬ÊÇ´óÐ͹¤ÒµÍø ÂçµÄÀíÏëÑ¡Ôñ¡£IKS-G6524µÄȫǧÕ×ͨѶÄÜÁ¦Ôö¼ÓÁË´ø¿íµÄÔËÄÜ£¬¿Éͨ¹ýÍøÂç¿ìËÙ´«Êä´óÁ¿ÒôƵ¡¢ÊÓƵºÍÊý¾ÝÐÅÏ¢¡£¸Ã½»»»»úÖ§³ÖTurbo Ring¡¢Turbo ChainºÍRSTP/ STPÈßÓàЭ Ò飬ÎÞ·çÉÈÉè¼Æ£¬¶ÀÁ¢ÈßÓàµçÔ´£¬Ôö¼ÓÁËϵͳµÄ¿É¿¿ÐÔºÍ¹Ç¸É ÍøÂçµÄ¿ÉÓÃÐÔ¡£

ÌصãºÍÓÅÊÆ

  • Ö§³ÖTurbo Ring¡¢Turbo ChainºÍRSTP/STPÍøÂçÈßÓà
  • Ö§³ÖIGMP SnoopingºÍGMRP£¬ÓÃÓڶಥ¹ýÂË
  • Ö§³ÖIEEE 802.1Q VLANºÍGVRPЭÒ飬ÇáËÉʵÏÖÍøÂç¹æ»®
  • Ö§³ÖQoS (IEEE802.1p/1Q) and TOS/DiffServ£¬Ôö¼ÓÍøÂçÈ·¶¨ÐÔ
  • Ö§³Ö802.3adºÍLACP£¬ÓÅ»¯ÍøÂç´ø¿í
  • Ö§³ÖIEEE802.1X£¬HTTPSºÍSSH£¬¼ÓÇ¿ÍøÂ簲ȫÐÔ
  • Ö§³ÖSNMPv1/v2c/v3²»Í¬µÈ¼¶µÄÍøÂç¹ÜÀíЭÒé
  • Ö§³ÖRMON£¬ÓÐЧ¼à¿ØÍøÂç
  • Ö§³Ö´ø¿í¹ÜÀí£¬È·±£ÍøÂçÐÔÄÜÎȶ¨
  • Ö§³Ö»ùÓÚMACµØÖ·µÄ¶Ë¿ÚËø¶¨£¬·ÀÖ¹·Ç·¨ÈëÇÖ
  • Ö§³Ö¶Ë¿Ú¾µÏñ¹¦ÄÜ£¬±ãÓÚÔÚÏßµ÷ÊÔ
  • ͨ¹ýe-mailºÍ¼ÌµçÆ÷Êä³ö×Ô¶¯±¨¸æÒâÍâʼþ
  • ×Ô¶¯»Ö¸´ËùÁ¬É豸µÄIPµØÖ·
  • ¿ìËÙ»Ö¸´Ïß·½»»»
  • ¿Éͨ¹ýWebä¯ÀÀÆ÷£¬Telnet/Serial Console£¬Windows¹¤¾ß½øÐÐÅäÖÃ

¼¼Êõ ±ê×¼£ºIEEE 802.3 for 10BaseT
IEEE 802.3u for 100BaseT(X) and 100BaseFX
IEEE 802.3ab for 1000BaseT(X)
IEEE 802.3z for 1000BaseSX/LX/LHX/ZX
IEEE 802.3x for Flow Control
IEEE 802.1D for Spanning Tree Protocol
IEEE 802.1w for Rapid STP
IEEE 802.1Q for VLAN Tagging
IEEE 802.1p for Class of Service
IEEE 802.1X for Authentication
IEEE 802.3ad for Port Trunk with LACP
ЭÒ飺IGMPv1/v2 device, GMRP, GVRP, SNMPv1/v2c/v3,
DHCP Server/Client, DHCP Option 82, BootP, TFTP, SNTP,
SMTP, RARP, RMON, HTTP, HTTPS, Telnet, SSH, Syslog
MIB: MIB-II, Ethernet-like MIB, P-BRIDGE MIB, Q-BRIDGE
MIB, Bridge MIB, RSTP MIB, RMON MIB Groups 1, 2, 3, 9
Á÷¿Ø£ºIEEE 802.3x flow control, back pressure flow control
½»»»»úÊôÐÔ ÓÅÏȼ¶£º8
×î¶à¿ÉÓÃVLANÊý£º256
VLAN ID·¶Î§£ºVID 1 ~ 4094
IGMP×éȺ£º512
MACµØÖ·²¾´óС£º16 K
Êý¾Ý±¨»º´æ´óС£º8 Mbit
½Ó¿Ú ǧÕ×ÒÔÌ«Íø¿Ú£º10/100/1000BaseT(X) or 100/1000BaseSFP slot
Console¿Ú£ºRS-232 (RJ45 connector)
LEDָʾµÆ£ºSTAT, PWR1, PWR2, FAULT, MSTR/HEAD, CPLR/
TAIL
±¨¾¯´¥µã£º1¸ö¼ÌµçÆ÷ÊäÈ룬µçÁ÷¸ºÔØÄÜÁ¦2 A @ 30 VDC
Êý×ÖÊäÈ룺1 input with the same ground, but electrically isolated
from the electronics.
• +13 to +30V for state¡° 1¡±
• -30 to +3V for state¡° 0¡±
• ×î´óÊäÈëµçÁ÷£º8 mA
µçÔ´ÐèÇó ÊäÈëµçѹ£º110/220 VAC (85 ~ 264 VAC)
ÊäÈëµçÁ÷£ºMax.0.79/0.44 A @ 110/220 VDC
¹ýÁ÷±£»¤£»ÓÐ
·´½Ó±£»¤£ºÓÐ
»úеÌØÐÔ Íâ¿Ç£ºIP30 ·À»¤µÈ¼¶
³ß´ç£º440 x 44 x 378 mm (17.32 x 1.73 x 14.88 in)
°²×°£º19»ú¼Ü°²×°
¹¤×÷»·¾³ ¹¤×÷ζȣº
±ê×¼Ðͺţº0 ~ 60 ¡ãC (32 ~ 140 ¡ãF)
¿íÎÂÐͺţº-40 ~ 75 ¡ãC (-40 ~ 167 ¡ãF)
´æ´¢Î¶ȣº-40 ~ 85 ¡ãC (-40 ~ 185 ¡ãF)
Ïà¶Ôʪ¶È£º5 ~ 95% ( ÎÞÄý¶)

 


¹«Ë¾¼ò½é
²úƷĿ¼
¹©Ó¦ÐÅÏ¢

¹«Ë¾Ãû³Æ£º Ħɯ¹ú¼ÊóÒ×£¨ÉϺ££©ÓÐÏÞ¹«Ë¾
µç »°£º 021 52589955 / Íõ С ½ã
ÊÖ»ú£º
µØ Ö·£º ÉϺ£ÊÐÑÓ°²Î÷·1160ºÅÊ×ÐÅÒø¶¼¹ú¼Ê¹ã³¡18²ã
ÓÊ ±à£º 200052
Ö÷ Ò³£º http://www.moxa.com.cn

¸Ã³§ÉÌÏà¹Ø²úÆ·£º
  • moxa EDR-810ϵÁÐ
  •  
  • moxa MD-119ϵÁÐ º£ÊÂרÓÃÏÔʾÆ÷
  •  
  • moxa MXview2.3ÍøÂç¹ÜÀíÈí¼þ
  •  
  • moxa ioLogik R1241
  •  
  • ioLogik R1240
  •  
  • moxa ioLogik R1214
  •  
  • moxa ioLogik R1212
  •  
  • moxa ioLogik R1210
  •  
  • moxa IEX-402-VDSL2ϵÁÐ
  •  
  • moxa MGate™ 5102-PBM-PNϵÁÐ
  •  
    ¸ü¶à²úÆ·...
      ¹ØÓÚÎÒÃÇ | ÁªÏµÎÒÃÇ | ¹ã¸æ·þÎñ | ±¾Õ¾¶¯Ì¬ | ÓÑÇéÁ´½Ó | ·¨ÂÉÉùÃ÷ | ·Ç·¨ºÍ²»Á¼ÐÅÏ¢¾Ù±¨  
    ¹¤¿ØÍø¿Í·þÈÈÏߣº0755-86369299
    °æȨËùÓÐ ¹¤¿ØÍø Copyright@ Gkong.com, All Rights Reserved