²úÆ·Ãû³Æ£º PT-G7509
ÐÍ ºÅ£º PT-G7509
¼Û ¸ñ£º 0.00
Æ· ÅÆ£º Ħɯ
 
Êղش˲úÆ·     ²é¿´ÊÕ²Ø

¼ò½é

PowerTrans PT-G7509¾ßÓÐ9¸öcombo GigabitÒÔÌ«ÍøÂçÁ¬½Ó¶Ë¿Ú£¬Ð­ÖúÄú½«ÏÖÓÐÍøÂçÁ¢¼´Éý¼¶Îª¸ßƵ¿íµÄGigabit´«ÊäËÙÂÊ£¬²¢½¨ÖÃÈ«Gigabit¹Ç¸ÉÍøÂç¡£PT-G7509µÄÉè¼Æ·ûºÏ¶àÖÖÓ¦ÓÃÁìÓòµÄÑÏ¿ÁµÄÒªÇ󣬰üÀ¨±äµçÕ¾×Ô¶¯»¯ÏµÍ³ (IEC 61850-3¡¢IEEE 1613)¡¢½»Í¨¿ØÖÆϵͳ (NEMA TS 2)£¬ºÍÌú·ӦÓÃ(EN50155/EN50121-4)¡£GigabitÍøÂç¿É´ó·ùÌá¸ß¿ÉÓÃƵ¿íÒÔÌṩ¸ü¸ßµÄ´«ÊäЧÄÜ£¬²¢ÇÒÄÜ¿çÍø¿ìËÙ´«ËÍ´óÁ¿µÄӰƬ¡¢ÉùÒôºÍÊý¾Ý¡£¶ø±¸Ô®ÒÔÌ«ÍøÂçTurbo Ring¡¢Turbo ChainºÍRSTP/STP (IEEE 802.1w/D)¹¦Äܸü¿ÉЭÖúÄúÌá¸ß¹Ç¸ÉÍøÂçµÄ¿É¿¿ÐÔÓë¿ÉÓÃÐÔ¡£PT-G7509²¢Ìṩǰ³öÏß»òºó³öÏßÁ½ÖÖÑ¡Ôñ£¬Âú×ãÄú²»Í¬Ó¦ÓÃÀàÐ͵ĽÓÏßÐèÇó¡£

Ìصã

  • »ñµÃ IPv6 Ready logoÈÏ¿É (IPv6 LogoίԱ»áÈÏÖ¤)
  • IEEE 1588 PTP (Precision Time Protocol) Ö§³Ö¾«È·µÄÍøÂçʱ¼äͬ²½
  • DHCP Option 82ÓÃÓÚ²»Í¬·½ÕëÏ嵀 IP µØÖ··ÖÅä
  • Ö§³ÖModbus/TCP¹¤Òµ¼¶ÒÔÌ«ÍøÂçЭÒé
  • Turbo Ring¡¢Turbo ChainºÍIEEE 802.1D-2004 RSTP/STP
  • IGMP snoopingºÍGMRP¿É¹ýÂ˹¤ÒµÒÔÌ«ÍøÂçЭÒéÖеĶàµã²¥ËÍÁ÷Á¿
  • IEEE 802.1Q VLANºÍGVRPЭÒ飬¼ò»¯ÍøÂç¹æ»®¹¤×÷
  • QoS (IEEE 802.1p/1Q)ºÍTOS/DiffServÌá¸ßÊý¾Ý´«ËÍÈ·¶¨ÐÔ
  • IEEE 802.3ad£¬LACP ÓÅ»¯Æµ¿íÀûÓÃ
  • SNMPv3¡¢IEEE 802.1X¡¢HTTPSºÍSSH¼ÓÇ¿ÍøÂ簲ȫÐÔ
  • SNMPv1/v2c/v3£¬¿ÉÖ´Ðи÷Öֵȼ¶µÄÍøÂç¹ÜÀí
  • RMONЭÖúÌáÉýÍøÂç¼à¿ØЧÂʲ¢ÌṩԤ²âÄÜÁ¦
  • Ƶ¿í¹ÜÀí¹¦ÄܿɱÜÃâ²»¿ÉÔ¤²âµÄÍøÂç×´¿ö
  • ¶Ë¿ÚËø¶¨¹¦ÄÜ£¬ÒÀ¾ÝMACµØÖ·ÏÞÖÆ´æÈ¡
  • Port mirroringÓÃÓÚÔÚÏß³ý´í
  • ¿É͸¹ýµç×ÓÓʼþ»òrelayÊä³ö×Ô¶¯·¢³öʼþ¾¯¸æ
  • ×Ô¶¯Õì²âÒÑÁ¬½ÓÉ豸µÄIPµØÖ·
  • »»Ïß¿ìËٻظ´Á¬½Ó (Line-swap fast recovery)
  • ¿Éͨ¹ýÍøÒ³ä¯ÀÀÆ÷¡¢Telnet/´®ÐÐÖ÷¿Ø̨¡¢Windows¹«ÓóÌÐòºÍABC-01×Ô¶¯±¸·ÝÅäÖÃÆ÷½øÐÐÅäÖÃÉ趨

¼¼Êõ ±ê×¼£º
10BaseTµÄIEEE 802.3
100BaseT(X)ºÍ100BaseFXµÄIEEE 802.3u
1000BaseT(X)µÄIEEE 802.3ab
1000BaseXµÄIEEE 802.3z
ÓÃÓÚÁ÷Á¿¿ØÖƵÄIEEE 802.3x
Spanning Tree ProtocolµÄIEEE 802.1D
ÓÃÓÚRapid STPµÄIEEE 802.1w
VLAN TaggingµÄIEEE 802.1Q
Class of ServiceµÄIEEE 802.1p
ÓÃÓÚÑéÖ¤µÄIEEE 802.1X
Port Trunk (º¬ LACP) µÄIEEE 802.3ad
ͨѶЭÒ飺IGMP v1/v2¡¢GMRP¡¢GVRP¡¢SNMPv1/v2c/v3¡¢
DHCP Server/Client¡¢BootP¡¢TFTP¡¢SNTP¡¢SMTP¡¢RARP¡¢
RMON¡¢HTTP¡¢HTTPS¡¢Telnet¡¢SSH¡¢Syslog¡¢DHCP
Option 66/67/82¡¢LLDP¡¢Modbus/TCP¡¢IEEE 1588 PTP¡¢
IPv6¡¢SNMP Inform
MIB£ºMIB-II¡¢Ethernet-like MIB¡¢P-BRIDGE MIB¡¢
Q-BRIDGE MIB¡¢Bridge MIB¡¢RSTP MIB¡¢RMON MIB
Group 1¡¢2¡¢3¡¢9
Á÷Á¿¿ØÖÆ£ºIEEE 802.3x Á÷Á¿¿ØÖÆ¡¢±³Ñ¹Ê½Á÷Á¿¿ØÖÆ
½»»»»úÊôÐÔ ÓÅÏȶÓÁУº4
×î´ó VLAN ÊýÁ¿ÉÏÏÞ£º64
VLAN ID ·¶Î§£ºVID 1 ÖÁ 4094
IGMP Ⱥ×飺256
½çÃæ RJ45¿Ú£º10/100/1000BaseT(X) ×Ô¶¯µ÷ÕûËÙÂÊ
¹âÏËÁ¬½Ó¶Ë¿Ú£º100/1000BaseSFP²å²Û
Ö÷¿Ø̨£ºRS-232 (RJ45 Á¬½ÓÍ·)
ϵͳLEDָʾµÆ£ºSTAT¡¢PWR1¡¢PWR2¡¢FAULT¡¢MSTR/
HEAD¡¢CPLR/TAIL
״̬LEDָʾµÆ£ºLNK/ACT¡¢FDX/HDX¡¢RING PORT¡¢
COUPLER¡¢PORT¡¢SPEED
¾¯¸æ½Óµã£ºÒ»¸örelayÊä³ö£¬µçÁ÷¸ºÔØÈÝÁ¿3A @ 30 VDC»ò3A
@ 240 VAC
µçÔ´ÐèÇó ÊäÈëµçѹ£º
• 24 VDC (18 ÖÁ 36 V)
• 48 VDC (36 ÖÁ 72 V)
• 110/220 VDC/VAC (88 ÖÁ 300 VDC£¬85 ÖÁ 264 VAC)
ÊäÈëµçÁ÷£º(ËùÓÐÁ¬½Ó¶Ë¿Ú½Ô×°ÖùâÏË)
• ×î¸ß 1.17 A @ 24 VDC
• ×î¸ß 0.59 A @ 48 VDC
• ×î¸ß 0.27/0.16 A @ 110/220 VDC
• ×î¸ß 0.61/0.35 A @ 110/220 VAC
µçÁ÷¹ýÔر£»¤£ºÓÐ
Á¬½Ó·½Ê½£º10Õë½Å¶Ë×Ǫ́
·´Ïò¼«ÐÔ±£»¤£ºÓÐ
»úеÌØÐÔ Íâ¿Ç£ºIP30 ·À»¤µÈ¼¶
³ß´ç£º440 x 44 x 254 mm
ÖØÁ¿£º3300 g
°²×°·½Ê½£º19Ó¢´ç»ú¼Üʽ°²×°
ʹÓû·¾³ ¹¤×÷ζȣº-40 ~ 85 ¡ãC (-40 ~ 185 ¡ãF)£¬-40¡ãCÖ®ÏÂÀ俪»ú×î
ÉÙÐèÒª100 VAC
´æ·Åζȣº-40 ~ 85 ¡ãC (-40 ~ 185 ¡ãF)
ÖÜΧÏà¶Ôʪ¶È£º5 ~ 95% (·ÇÀäÄý)

 


¹«Ë¾¼ò½é
²úƷĿ¼
¹©Ó¦ÐÅÏ¢

¹«Ë¾Ãû³Æ£º Ħɯ¹ú¼ÊóÒ×£¨ÉϺ££©ÓÐÏÞ¹«Ë¾
µç »°£º 021 52589955 / Íõ С ½ã
´« Õ棺 021-52585505
µØ Ö·£º ÉϺ£ÊÐÑÓ°²Î÷·1160ºÅÊ×ÐÅÒø¶¼¹ú¼Ê¹ã³¡18²ã
ÓÊ ±à£º 200052
Ö÷ Ò³£º http://www.moxa.com.cn

¸Ã³§ÉÌÏà¹Ø²úÆ·£º
  • moxa EDR-810ϵÁÐ
  •  
  • moxa MD-119ϵÁÐ º£ÊÂרÓÃÏÔʾÆ÷
  •  
  • moxa MXview2.3ÍøÂç¹ÜÀíÈí¼þ
  •  
  • moxa ioLogik R1241
  •  
  • ioLogik R1240
  •  
  • moxa ioLogik R1214
  •  
  • moxa ioLogik R1212
  •  
  • moxa ioLogik R1210
  •  
  • moxa IEX-402-VDSL2ϵÁÐ
  •  
  • moxa MGate™ 5102-PBM-PNϵÁÐ
  •  
    ¸ü¶à²úÆ·...
      ¹ØÓÚÎÒÃÇ | ÁªÏµÎÒÃÇ | ¹ã¸æ·þÎñ | ±¾Õ¾¶¯Ì¬ | ÓÑÇéÁ´½Ó | ·¨ÂÉÉùÃ÷ | ·Ç·¨ºÍ²»Á¼ÐÅÏ¢¾Ù±¨  
    ¹¤¿ØÍø¿Í·þÈÈÏߣº0755-86369299
    °æȨËùÓÐ ¹¤¿ØÍø Copyright@ Gkong.com, All Rights Reserved