Ê×Ò³ - ÐÂÎÅ - ÕÐƸ - ÏÂÔØ - ²úÆ· - ³§ÉÌ - ·½°¸ - ÎÄÕª - Çó¹º - Õ¹ÀÀ
Ãâ·Ñ×¢²á µÇ¼ | ¹ã¸æ·þÎñ | ¿Í·þÖÐÐÄ
Öлª¹¤¿ØÍø ¡ú ¹¤¿Ø²úÆ· ¡ú TN-5508ϵÁÐ
²úÆ·Ãû³Æ£º TN-5508ϵÁÐ
ÐÍ ºÅ£º TN-5508
¼Û ¸ñ£º 0.00
Æ· ÅÆ£º Ħɯ
 
Êղش˲úÆ·     ²é¿´ÊÕ²Ø

¼ò½é

ToughNet TN-5500ϵÁÐM12Íø¹ÜÐÍÒÔÌ«Íø½»»»»úרΪ¶ñÁÓ»·¾³µÄ¹¤ÒµÓ¦ÓÃÉè¼Æ¡£TNϵÁвÉÓÃM12¼°ÆäËûÔ² ÐνÓͷʵÏÖ½ôÃÜ¡¢¼á¹ÌµÄÁ¬½Ó£¬ÃâÊÜÕ𶯺ͳå»÷µÈ»·¾³Ó°Ï죬ȷ±£Îȶ¨µÄÔËÐС£TN-5500-LV-MV½»»»»úÌṩ 12/24/36/48/72/96/110 VDC¶àÖÖµçÔ´ÊäÈ룬һÖÖÐͺż´¿ÉÂú×ãÄúÈ«ÇòÓ¦ÓõÄÐèÇó¡£´ËÍ⣬12/24/36/48 VDC,72/96/110 VDC»òÕß110/220 VDC/VACË«¸ôÀëÈßÓàµçÔ´ÊäÈ뻹¿ÉÔö¼ÓÍøÂçͨÐŵÄÎȶ¨ÐÔ£¬½ÚÊ¡²¼Ï߳ɱ¾¡£TN-5500Å䱸8¸ö»ò16¸ö¿ìËÙÒÔÌ«ÍøM12¿Ú£¬TN-5510/5518µ×²àÅ䱸2¸ö´ø¼ÌµçÆ÷ÅÔ·¹¦ÄܵÄǧÕ×ÒÔÌ«ÍøRJ45½Ó¿Ú¡£ÓÐ-40~ 75 ¡ãC¹¤×÷ζȵĿíλúÐÍ¡£TN-5500ϵÁн»»»»úÂú×ãEN50155/50121-3-2/50121-4£¨¹ìµÀ½»Í¨Ó¦Óã©£¬NEMA TS2£¨½»Í¨¿ØÖÆϵͳ£©Óëe-mark£¨³µÁ¾£©µÄÒªÇ󣬹㷺ÊÊÓÃÓÚ¶àÖÖ¹¤ÒµÓ¦Óá£

Ìصã

• ¼´Ê¹É豸ÒòµçÔ´¹ÊÕϲ»¹¤×÷£¬2¸öǧÕ×ÒÔÌ«ÍøRJ45 ½Ó¿ÚµÄ¼ÌµçÆ÷ÅÔ·¹¦ÄÜÒ²¿ÉÈ·±£Êý¾ÝͨÐÅ¡£
• 3¸öÐýת¿ª¹ØÓÃÀ´ÉèÖÃIPµØÖ·µÄ×îºó3λÊý×Ö£¬Î¬»¤¸ü·½±ã
• IPv6 ReadyÈÏÖ¤£¨IPv6±ê־ίԱ»áÈÏÖ¤£©
• IEEE 1588PTP£¨¾«ÃÜʱ¼äЭÒ飩£¬ÓÃÓÚÓëÍøÂçͬ²½µÄ׼ȷʱ¼ä
• DHCP Opition 82£¬ÓÃÓÚÒÔ²»Í¬²ßÂÔ·ÖÅäIPµØÖ·
• Ö§³Ö¹¤ÒµÒÔÌ«ÍøЭÒéModbus/TCP
• Ö§³ÖTurbo RingºÍRSTP/STP(IEEE802.1W/D)
• IGMP SnoopingºÍGMRPÓÃÓÚ¹ýÂ˹¤ÒµÒÔÌ«ÍøЭÒéÖеĶಥÁ÷Á¿
• Ö§³Ö»ùÓڶ˿ڵÄVLAN¡¢IEEE802.1Q VLAN ºÍGVRPЭÒ飬ʹÍøÂç¹æ»®¼òµ¥Ò×ÐÐ
• Ö§³ÖQoS-IEEE 802.1p/1QºÍTOS/DiffServ£¬Ôö¼Ó¾ö¶¨È¨
• Ö§³ÖIEEE 802.3adºÍLACPÓÅ»¯´ø¿íÀûÓÃ
• Ö§³ÖIEEE 802.1XºÍhttps/SSL£¬ÔöÇ¿ÍøÂ簲ȫÐÔ
• Ö§³ÖSNMP V1/V2c/V3ÒÔ½øÐв»Í¬ÍøÂç²ã¼¶¼äµÄ¹ÜÀí
• RMON¹¦ÄÜÄܹ»ÌṩÓÐЧµÄÍøÂç¼àÊÓºÍÔ¤²âÄÜÁ¦
• Ƶ¿íÁ÷Á¿¹ÜÀí¹¦ÄܱÜÃâ·ÇÔ¤ÆÚµÄÍøÂç״̬
• ¶Ë¿ÚËø¶¨½öÔÊÐíÊÚȨ MAC µØÖ··ÃÎÊ
• ¶Ë¿Ú¾µÏñ¿ÉÓÃÓÚÔÚÏßµ÷ÊÔ
• ͨ¹ýE-mail¡¢¼ÌµçÆ÷Êä³ö£¬ÊµÏÖ×Ô¶¯±¨¾¯
• »»ÏßÁ¬½Ó¿ìËÙ»Ö¸´
• ¿Éͨ¹ýWebä¯ÀÀÆ÷£¬Telnet / ´®¿Ú¿ØÖÆ̨£¬Windows¹¤¾ßÅäÖÃ
• Ãæ°å°²×°»òµ¼¹ì°²×°·½Ê½

¼¼Êõ ±ê×¼£ºIEEE 802.3 10BaseT
IEEE 802.3u 100BaseT(X)
IEEE 802.3ab 1000BaseT(X)
IEEE 802.3xÁ÷Á¿¿ØÖÆ
IEEE 802.1DÉú³ÉÊ÷ЭÒé
IEEE 802.1W¿ìËÙÉú³ÉÊ÷ЭÒé
IEEE 802.1Q VLAN񈬀
IEEE 802.1D·þÎñ¼¶±ð
IEEE 802.1WЭÒéÈÏÖ¤
IEEE 802.3ad£¬ÓÃÓÚÓëLACPÒ»ÆðµÄ¶Ë¿ÚÐÅϢͨ·
ЭÒ飺GMPv1/v2 device£¬GMRP£¬GVRP£¬SNMPv1/v2C/
v3£¬DHCP·þÎñÆ÷/¿Í»§¶Ë£¬DHCP Option 66/67/82£¬BootP£¬
TFTP£¬SNTP£¬SMTP£¬RARP£¬RMON£¬HTTP£¬HTTPS£¬
Telent£¬SSH£¬Syslog£¬LLDP£¬IEEE 1588 PTP£¬Modbus/
TCP£¬IPv6
MIB£ºMIB-II£¬Ethernet-like MIB£¬P-BRIDGE MIB£¬QBRIDGE
MIB£¬Bridge MIB£¬RSTP MIB£¬RMON MIB Group
1£¬2£¬3£¬9
Á÷¿Ø£ºIEEE 802.3xÁ÷¿Ø¡¢±³Ñ¹Ê½Á÷¿Ø
ÓÅÏȼ¶¶ÓÁУº
VLAN×î´ó¿ÉÓÃÊýÁ¿£º64
VLAN ID ·¶Î§£º1 ¡« 4094
IGMP×飺256
½Ó¿Ú ¿ìËÙÒÔÌ«Íø£ºÇ°²à³öÏߣ¬M12 ½ÓÍ·£¬10/100BaseT(X) ×ÔÕì²â,
È«/°ëË«¹¤Ä£Ê½£¬MDI/MDIX ×ÔÊÊÓ¦
µ×²à³öÏߣ¬10/100/1000BaseT(X)×Ô¶¯Õì²â£¬È«/°ëË«¹¤Ä£Ê½£¬
MDI/MDI-X×ÔÊÊÓ¦
¿ØÖÆ̨¶Ë¿Ú£ºM12 A-coding, 5-pin Õëʽ½ÓÍ·
ϵͳLEDָʾµÆ£ºPWR1, PWR2, FAULT, MASTER, COUPLER
¶Ë¿ÚLEDָʾµÆ£º10/100M (¿ìËÙÒÔÌ«Íø¿Ú), 10/100/1000M
(ǧÕ×ÒÔÌ«Íø¿Ú)
±¨¾¯Êä³ö£º1¸öM12 A-coding 5-pinÕëʽ½ÓÍ·Á½Â·¼ÌµçÆ÷Êä
³ö±¨¾¯, µçÁ÷¸ºÔØÄÜÁ¦3 A @ 30 VDC »ò3 A @ 240 VAC
Ðýת¿ª¹Ø£ºÉèÖÃIP µØÖ·µÄ×îºó3λÊý×Ö
µçÔ´ ÊäÈëµçѹ£º
12/24/36/48 VDC (8.4 ~ 60 VDC)
72/96/110 VDC (50.4 ~ 154 VDC)
110/220 VDC/VAC (88 ~ 300 VDC, 85 ~ 264 VAC)
¹ýÁ÷±£»¤£ºÌṩ
Á¬½Ó·½Ê½£ºM23 A-coding, 5-pin Õëʽ½ÓÍ·
·´½Ó±£»¤£ºÌṩ
»úеÌØÐÔ Íâ¿Ç£ºIP54·À»¤µÈ¼¶£¬½ðÊôÍâ¿Ç
³ß´ç£º
250 x 170 x 69.8 mm (W x H x D) (9.84 x 6.69 x 2.75 in)
°²×°·½Ê½£ºÃæ°å¡¢µ¼¹ì°²×°£¨¿ÉÑ¡¸½¼þ£©
¹¤×÷»·¾³ ¹¤×÷ζȣº
±êÎÂÐÍ£º0 ~ 60 ¡ãC (32 ~ 140 ¡ãF)
¿íÎÂÐÍ£º-40~ 75¡ãC (-40 ~ 167¡ãF)
´¢´æζȣº-40 ~ 85¡ãC (-40 ~ 185¡ãF)
¹¤×÷ʪ¶È£º5~95% RH (ÎÞÄý¶)

 


¹«Ë¾¼ò½é
²úƷĿ¼
¹©Ó¦ÐÅÏ¢

¹«Ë¾Ãû³Æ£º Ħɯ¹ú¼ÊóÒ×£¨ÉϺ££©ÓÐÏÞ¹«Ë¾
µç »°£º 021 52589955 / Íõ С ½ã
´« Õ棺 021-52585505
µØ Ö·£º ÉϺ£ÊÐÑÓ°²Î÷·1160ºÅÊ×ÐÅÒø¶¼¹ú¼Ê¹ã³¡18²ã
ÓÊ ±à£º 200052
Ö÷ Ò³£º http://www.moxa.com.cn

¸Ã³§ÉÌÏà¹Ø²úÆ·£º
  • moxa EDR-810ϵÁÐ
  •  
  • moxa MD-119ϵÁÐ º£ÊÂרÓÃÏÔʾÆ÷
  •  
  • moxa MXview2.3ÍøÂç¹ÜÀíÈí¼þ
  •  
  • moxa ioLogik R1241
  •  
  • ioLogik R1240
  •  
  • moxa ioLogik R1214
  •  
  • moxa ioLogik R1212
  •  
  • moxa ioLogik R1210
  •  
  • moxa IEX-402-VDSL2ϵÁÐ
  •  
  • moxa MGate™ 5102-PBM-PNϵÁÐ
  •  
    ¸ü¶à²úÆ·...