¼ò½é

EDS-P510 ϵÁÐÍø¹ÜÐÍǧÕ×ÈßÓàÒÔÌ«Íø½»»»»ú±êÅä 4 ¸ö 10/100BaseT(X) 802.3af (PoE) ¼æÈÝÒÔÌ«Íø¿ÚÒÔ¼°3¸öǧÕ××éºÏÒÔÌ«Íø¿Ú¡£Ã¿¸ö PoE ¶Ë¿ÚÌṩ×î¸ß 15.4 W µÄµçÔ´£¬ÔÚ½»Á÷µçÔ´²»±ãʹÓûòÊܼ۸ñÒòËØÏÞÖÆʱÌṩ¸øÏàÁ¬É豸£¨Èç¼à¿ØÉãÏñ»ú¡¢ÎÞÏß½ÓÈëµãºÍIP µç»°£©¡£Æ书Äܷḻ£¬SFP ¹âÏ˶˿ڴ«ÊäÊý¾Ýµ½¿ØÖÆÖÐÐĵľàÀë×î¸ß´ï80¹«À²¢¾ßÓи߿¹µç´Å¸ÉÈÅÄÜÁ¦¡£Ö§³Ö¶àÖÖ¹ÜÀí¹¦ÄÜ£¬°üÀ¨ Turbo Ring¡¢RSTP/STP¡¢IGMP¡¢VLAN¡¢QoS¡¢RMON¡¢´ø¿í¹ÜÀíºÍ¶Ë¿Ú¾µÏñ¡£EDS-P510 ÒòÆäÖ§³Ö¿ÉÀ©Õ¹µÄÖ÷¸ÉÍø½á¹¹ÒÔ¼°ÒÔÌ«Íø¹©µç£¬ÓÈÆäÊÊÓÃÓÚ×Ô¶¯»¯°²È«Ó¦Óã¨ÈçIP¼à¿ØºÍÃŽûϵͳ£©¡£

Ìصã

- ÏȽøµÄPoE¹ÜÀí¹¦ÄÜ
- IPv6 ReadyÈÏÖ¤£¨IPv6±ê־ίԱ»áÈÏÖ¤£©
- IEEE 1588PTP£¨¾«ÃÜʱ¼äЭÒ飩£¬ÓÃÓÚÓëÍøÂçͬ²½µÄ׼ȷʱ¼ä
- DHCP Opition 82£¬ÓÃÓÚÒÔ²»Í¬²ßÂÔ·ÖÅäIPµØÖ·
- Ö§³Ö¹¤ÒµÒÔÌ«ÍøЭÒéModbus/TCP
- Ö§³ÖIEC 61850 GOOSEÏûÏ¢´«µÝ
- Turbo Ring£¨ÂúÔØʱ×ÔÓúʱ¼ä<20ms£©ºÍRSTP/STP (IEEE 802.1w/D)
- IGMP SnoopingºÍGMRP£¬ÓÃÓÚ¹ýÂ˹¤ÒµÒÔÌ«ÍøЭÒéÖеĶಥÁ÷Á¿
- Ö§³Ö»ùÓڶ˿ڵÄVLAN¡¢IEEE802.1Q VLAN ºÍGVRPЭÒ飬ʹÍøÂç¹æ»®¼òµ¥Ò×ÐÐ
- Ö§³ÖQos---IEEE 802.1p/1QºÍTOS/DiffServ£¬Ôö¼Ó¾ö¶¨È¨
- Ö§³Ö¶Ë¿ÚÖм̣¬×î´ó»¯ÀûÓôø¿í
- Ö§³ÖIEEE 802.1X, HTTPS, and SSH£¬ÔöÇ¿ÍøÂçµÄ°²È«ÐÔ
- SNMP V1/V2c/V3Õë¶Ô²»Í¬µÈ¼¶µÄÍøÂç¹ÜÀí
- RMON¹¦ÄÜÄܹ»ÌṩÓÐЧµÄÍøÂç¼àÊÓºÍÔ¤²âÄÜÁ¦
- ´ø¿í¹ÜÀíÄܹ»Ô¤·À²»¿ÉÔ¤¼ÆµÄÍøÂç״̬
- Ëø¶¨¶Ë¿Ú½öÔÊÐíÊÚȨMACµØÖ··ÃÎÊ
- ¶Ë¿Ú¾µÏñ¿ÉÓÃÓÚÔÚÏßµ÷ÊÔ

¼¼Êõ ±ê×¼: IEEE 802.3af£¬ÓÃÓÚÒÔÌ«Íø¹©µç
IEEE 802.3£¬ÓÃÓÚ10BaseT
IEEE 802.3u£¬ÓÃÓÚ100BaseT(X) ºÍ100Base FX
IEEE 802.3ab£¬ÓÃÓÚ1000BaseT(X)
IEEE 802.3z£¬ÓÃÓÚ1000BaseSX/LX/LHX/ZX
IEEE 802.3x£¬ÓÃÓÚÁ÷Á¿¿ØÖÆ
IEEE 802.1D£¬ÓÃÓÚÉú³ÉÊ÷ÐÎЭÒ飨STP£©
IEEE 802.1w£¬ÓÃÓÚ¿ìËÙSTP
IEEE 802.1Q£¬ÓÃÓÚVLAN±ê¼Ç
IEEE 802.1p£¬ÓÃÓÚ·þÎñ¼¶±ð
IEEE 802.1X£¬ÓÃÓÚЭÒéÈÏÖ¤
IEEE 802.3ad£¬ÓÃÓÚÓëLACPÒ»ÆðµÄ¶Ë¿ÚÐÅϢͨ·
ЭÒé: IGMPv1/v2 É豸£¬GMRP, GVRP, SNMPv1/v2c/v3, DHCP
Server/Client, DHCP Option 66/67/82, BootP, TFTP, SNTP,
SMTP, RARP, RMON, HTTP, HTTPS, Telnet, SSH, Syslog,
LLDP, Modbus/ TCP, IEEE 1588 PTP, IPv6
MIB: MIB-II, Ethernet-Like MIB, P-BRIDGE MIB, Q-BRIDGE
MIB, Bridge MIB, RSTP MIB, RMON MIB Group 1, 2, 3, 9
Á÷¿Ø: IEEE 802.3x Á÷Á¿¿ØÖÆ£¬±³Ñ¹Ê½Á÷Á¿¿ØÖÆ
½»»»»úÐÔÄÜ ÓÅÏȼ¶¶ÓÁÐ: 4
VLAN×î´ó¿ÉÓÃÊýÁ¿: 64
VLAN ID ·¶Î§: 1 ~ 4094
IGMP×é: 256
½Ó¿Ú ¹âÏ˶˿Ú: 100/1000BaseSFP²å²Û
RJ45 ¶Ë¿Ú: 10/100BaseT£¨x£©»ò10/100/1000BaseT£¨X£©×ÔÕì ²âËÙ¶È
¿ØÖÆÆ÷: RS - 232£¨ RJ45£©
DIP¿ª¹Ø: Turbo Ring, Master, Coupler, Reserve
LEDָʾ: PWR1, PWR2, FAULT, 10/100/1000, 10/100,
MASTER, COUPLER, PoE
±¨¾¯Êä³ö: Á½Â·¼ÌµçÆ÷Êä³ö£¬µçÁ÷¸ºÔØÄÜÁ¦0.5A @ 48 VDC
Êý×ÖÊäÈë: µçÆø¸ôÀ룬¹²µØ¡£
•×´Ì¬ 1£º+13 ~ +30V
•×´Ì¬ 0 £º-30 ~ +3V
•×î´óÊäÈëµçÁ÷£º8mA
µçÔ´ ÊäÈëµçѹ: 48VDC£¨46 ~ 50V£©£¬ÈßÓàÊäÈë
ÊäÈëµçÁ÷: ×î´ó1.62@48VDC£¨¹¦ºÄΪ15.4 Wʱ£¬Ã¿¸öPoE
¶Ë¿Ú×î¶àÖ§³Ö4¸ö¶Ë¿Ú£©
¹ýµçÁ÷±£»¤: Ìṩ
Á¬½Ó: Á½¸ö¿ÉÒƶ¯ 6 Õë½ÓÏ߶Ë×Ó
·´½Ó±£»¤£ºÌṩ
»úеÐÔÄÜ Íâ¿Ç: IP30 ·À»¤µÈ¼¶£¬½ðÊôÍâ¿Ç
³ß´ç (W x H x D) £º80.2 x 135 x 105 mm (3.16 x 5.31 x 4.13
in)
ÖØÁ¿: 1170 g
°²×°·½Ê½: ¹ìµÀ°²×°£¬±Ú¹Òʽ°²×°£¨¿ÉÑ¡Ì×¼þ£©
¹¤×÷»·¾³ ¹¤×÷ζÈ:
±êΣº0 ¡« 60¡ãC£¨32 ~ 140¡ãF£©
¿íΣº -40¡æ ~ 75¡æ£¨-40 ~ 167¡ãF£©
´æ´¢Î¶È: -40 ~ 85¡ãC£¨-40 ~ 185¡ãF£©
Ïà¶Ôʪ¶È: 5 ~ 95£¥£¨ÎÞÄý¶£©

 


¹«Ë¾¼ò½é
²úƷĿ¼
¹©Ó¦ÐÅÏ¢

¹«Ë¾Ãû³Æ£º Ħɯ¹ú¼ÊóÒ×£¨ÉϺ££©ÓÐÏÞ¹«Ë¾
µç »°£º 021 52589955 / Íõ С ½ã
´« Õ棺 021-52585505
µØ Ö·£º ÉϺ£ÊÐÑÓ°²Î÷·1160ºÅÊ×ÐÅÒø¶¼¹ú¼Ê¹ã³¡18²ã
ÓÊ ±à£º 200052
Ö÷ Ò³£º http://www.moxa.com.cn

¸Ã³§ÉÌÏà¹Ø²úÆ·£º
  • moxa EDR-810ϵÁÐ
  •  
  • moxa MD-119ϵÁÐ º£ÊÂרÓÃÏÔʾÆ÷
  •  
  • moxa MXview2.3ÍøÂç¹ÜÀíÈí¼þ
  •  
  • moxa ioLogik R1241
  •  
  • ioLogik R1240
  •  
  • moxa ioLogik R1214
  •  
  • moxa ioLogik R1212
  •  
  • moxa ioLogik R1210
  •  
  • moxa IEX-402-VDSL2ϵÁÐ
  •  
  • moxa MGate™ 5102-PBM-PNϵÁÐ
  •  
    ¸ü¶à²úÆ·...
      ¹ØÓÚÎÒÃÇ | ÁªÏµÎÒÃÇ | ¹ã¸æ·þÎñ | ±¾Õ¾¶¯Ì¬ | ÓÑÇéÁ´½Ó | ·¨ÂÉÉùÃ÷ | ·Ç·¨ºÍ²»Á¼ÐÅÏ¢¾Ù±¨  
    ¹¤¿ØÍø¿Í·þÈÈÏߣº0755-86369299
    °æȨËùÓÐ ¹¤¿ØÍø Copyright@ Gkong.com, All Rights Reserved