Ê×Ò³ - ÐÂÎÅ - ÕÐƸ - ÏÂÔØ - ²úÆ· - ³§ÉÌ - ·½°¸ - ÎÄÕª - Çó¹º - Õ¹ÀÀ
Ãâ·Ñ×¢²á µÇ¼ | ¹ã¸æ·þÎñ | ¿Í·þÖÐÐÄ
Öлª¹¤¿ØÍø ¡ú ¹¤¿Ø²úÆ· ¡ú ICS-G7526/G7528 ϵÁÐ
²úÆ·Ãû³Æ£º ICS-G7526/G7528 ϵÁÐ
ÐÍ ºÅ£º ICS-G7526/G7528
¼Û ¸ñ£º 0.00
Æ· ÅÆ£º moxa
 
Êղش˲úÆ·     ²é¿´ÊÕ²Ø

¼ò½é

Éú²úÁ÷³Ì×Ô¶¯»¯ºÍ½»Í¨×Ô¶¯»¯Ó¦ÓÃ×éºÏÁ˸÷ÖÖÊÓƵÒôƵÊý¾Ý£¬Òò´ËÐèÒª¸ßÐÔÄܺ͸߿ɿ¿ÐÔµÄÍøÂç»·¾³¡£ICS-G7526/G7528ϵÁÐȫǧÕ׹Ǹɽ»»»»ú¾ß±¸¶à´ï24¸öǧÕ×ÒÔÌ«Íø¿Ú£¬ÒÔ¼°¶à´ï4¸ö(10 GbE)ÍòÕ×ÒÔÌ«Íø¿Ú£¬Ê¹ËûÃǺÜÊʺϴó¹æÄ£¹¤ÒµÍøÂç¡£ICS-G7526/G7528 µÄȫǧÕ×ÄÜÁ¦Ôö¼ÓÁË´ø¿í£¬Äܹ»Ìṩ¸ßÐÔÄܲ¢ÄÜ¿ìËÙÔÚÍøÂçÉÏ´«Êä´óÁ¿ÊÓƵÒôƵÊý¾Ý¡£¸ÃϵÁн»»»»úÖ§³ÖTurbo Ring£¬Turbo ChainºÍRSTP/STPÈßÓàЭÒ飬ÎÞ·çÉÈ£¬¸ôÀëÈßÓàµçÔ´£¬ÔöÇ¿ÁËϵͳ¿É¿¿ÐԺ͹ǸÉÍøÂçµÄ¿ÉÓÃÐÔ¡£

ÌØÕ÷ÓëÓÅÊÆ

  • »ñµÃIPv6 Ready logo (IPv6 LogoίԱ»áÈÏÖ¤)
  • IEEE 1588 PTP (¾«È·Ê±ÖÓЭÒé)£¬¾«È·ÍøÂçʱÖÓͬ²½
  • DHCP Option 82£¬Í¨¹ý²»Í¬·½·¨½øÐÐIPµØÖ··ÖÅä
  • Modbus/TCPЭÒ飬¶ÔÉ豸½øÐйÜÀíºÍ¼à¿Ø
  • Turbo Ring£¬Turbo ChainºÍRSTP/STPÍøÂçÈßÓ༼Êõ
  • IGMP SnoopingºÍGMRP£¬¹ýÂËÀ´×Ô¹¤ÒµÒÔÌ«ÍøЭÒéµÄ¶à²¥Á÷Á¿
  • IEEE 802.1Q VLANºÍGVRPЭÒ飬ÍøÂç¹æ»®¸üÇáËÉ
  • QoS (IEEE 802.1p/1Q)ºÍTOS/DiffServÔöÇ¿¶ÔÊý¾ÝÓÅÏÈȨµÄ¿ØÖÆ
  • 802.3adºÍLACPÓÅ»¯ÍøÂç´ø¿íʹÓÃ
  • IEEE 802.1X£¬HTTPSºÍSSH¼ÓÇ¿ÍøÂ簲ȫÐÔ
  • SNMPv1/v2c/v3½øÐв»Í¬¼¶±ðµÄÍøÂç¹ÜÀí
  • RMON ÓÃÓÚ¸üΪÓÐЧ£¬»ý¼«Ö÷¶¯µÄÍøÂçÉ豸¼à¿Ø
  • ´ø¿í¹ÜÀíÈ·±£Îȶ¨ÍøÂçÐÔÄÜ
  • ¡°¶Ë¿ÚËø¶¨¡±ÏÞ¶¨·ÃÎÊÊÚȨµÄMACµØÖ·
  • ¶Ë¿Ú¾µÏñÓÃÓÚÔÚÏßÕï¶Ï
  • e-mailºÍ¼ÌµçÆ÷Êä³ö×Ô¶¯ÒâÍⱨ¾¯

¼¼Êõ ±ê×¼£ºIEEE 802.3 10BaseT
IEEE 802.3u 100BaseT(X) /100BaseFX
IEEE 802.3ab 1000BaseT(X)
IEEE 802.3z 1000BaseSX/LX/LHX/ZX
IEEE 802.3ae 10GbE
IEEE 802.3x Á÷¿Ø
IEEE 802.1D STPÉú³ÉÊ÷ЭÒé
IEEE 802.1w ¿ìËÙ STP
IEEE 802.1Q VLAN Tagging
IEEE 802.1p Class of Service
IEEE 802.1X Óû§·ÃÎÊÑéÖ¤
IEEE 802.3ad ÊÊÓÃÓÚ»ùÓÚLACPµÄ¶Ë¿Ú¾ÛºÏ
ЭÒ飺 IGMPv1/v2 device, GMRP, GVRP, SNMPv1/v2c/v3, DHCP Server/Client, DHCP Option 66/67/82, BootP, TFTP, SNTP, SMTP, RARP, RMON, HTTP, HTTPS, Telnet, SSH, Syslog, Modbus/TCP, LLDP, IEEE 1588 PTP, IPv6
MIB£ºMIB: MIB-II, Ethernet-like MIB, P-BRIDGE MIB, Q-BRIDGE MIB, Bridge MIB, RSTP MIB, RMON MIB Groups 1, 2, 3, 9
Á÷¿Ø£ºIEEE 802.3xÁ÷¿Ø, ±³Ñ¹Ê½Á÷¿Ø
½»»»»úÊôÐÔ ÓÅÏȼ¶£º8
×î¶à¿ÉÓõÄVLANÊý£º256
VLAN ID ·¶Î§£ºVID 1 ~ 4094
IGMP ×飺1000
MACµØÖ·±í´óС£º16 K
·â°ü»º³åÇø´óС£º8 Mbit
½Ó¿Ú ǧÕ×ÒÔÌ«Íø£º10/100/1000BaseT(X) »ò100/1000BaseSF²Û
10 GbE£º10GbE SFP+²Û
¿ØÖÆ¿Ú£º RS-232 (RJ45 ½ÓÍ·)
LED ָʾµÆ£ºSTAT, PWR1, PWR2, FAULT, MSTR/HEAD, CPLR/TAIL
±¨¾¯´¥µã£º1¸ö¼ÌµçÆ÷ÊäÈ룬µçÁ÷¸ºÔØÄÜÁ¦2 A @ 30 VDC
Êý×ÖÊäÈ룺µçÆø¸ôÀ룬¹²µØ
• ״̬ 1£º+13 ~ +30 V
• ״̬ 0£º-30 ~ +3 V
• ×î´óÊäÈëµçÁ÷£º8 mA
µçÔ´ÐèÇó ÊäÈëµçѹ£º110/220 VAC (85 ~ 264 VAC)
ÊäÈëµçÁ÷£º
ICS-G7526: Max. 0.98/0.55 A @ 110/220 VAC ICS-G7528: Max. 1.16/0.65 A @ 110/220 VAC
¹ýµçÁ÷±£»¤£ºÓÐ
·´½Ó±£»¤£ºÓÐ
ÎïÀíÌØÐÔ Íâ¿Ç£ºIP30±£»¤
³ß´ç£º440 x 44 x 386.9 mm (17.32 x 1.73 x 15.23 in)
°²×°£º19Ó¢´ç»ú¼Ü°²×°
»·¾³ÐèÇó ¹¤×÷ζȣº0 ~ 60 ¡ãC (32 ~ 140 ¡ãF)´æ´¢Î¶ȣº-40 ~ 85 ¡ãC (-40 ~ 185 ¡ãF)
Ïà¶Ô»·¾³Êª¶È£º5 ~ 95%£¨ÎÞÄý¶£©
±ê×¼ºÍÈÏÖ¤ °²È«£ºUL 60950-1 (ÈÏÖ¤ÖÐ), EN 60950-1 (ÈÏÖ¤ÖÐ)
EMI£ºFCC Part 15 Subpart B Class A, EN 55022 Class A
¹ìµÀ½»Í¨£ºEN 50121-4
×¢Ò⣺Çë·ÃÎÊMoxaÍøÕ¾Á˽â×îÐÂÈÏÖ¤ÐÅÏ¢¡£
±£ÐÞ ±£ÐÞÆÚ£º5Äê
ÏêÇé:·ÃÎÊ www.moxa.com/warranty

 

 


¹«Ë¾¼ò½é
²úƷĿ¼
¹©Ó¦ÐÅÏ¢

¹«Ë¾Ãû³Æ£º Ħɯ¹ú¼ÊóÒ×£¨ÉϺ££©ÓÐÏÞ¹«Ë¾
µç »°£º 021 52589955 / Íõ С ½ã
´« Õ棺 021-52585505
µØ Ö·£º ÉϺ£ÊÐÑÓ°²Î÷·1160ºÅÊ×ÐÅÒø¶¼¹ú¼Ê¹ã³¡18²ã
ÓÊ ±à£º 200052
Ö÷ Ò³£º http://www.moxa.com.cn

¸Ã³§ÉÌÏà¹Ø²úÆ·£º
  • moxa EDR-810ϵÁÐ
  •  
  • moxa MD-119ϵÁÐ º£ÊÂרÓÃÏÔʾÆ÷
  •  
  • moxa MXview2.3ÍøÂç¹ÜÀíÈí¼þ
  •  
  • moxa ioLogik R1241
  •  
  • ioLogik R1240
  •  
  • moxa ioLogik R1214
  •  
  • moxa ioLogik R1212
  •  
  • moxa ioLogik R1210
  •  
  • moxa IEX-402-VDSL2ϵÁÐ
  •  
  • moxa MGate™ 5102-PBM-PNϵÁÐ
  •  
    ¸ü¶à²úÆ·...
      ¹ØÓÚÎÒÃÇ | ÁªÏµÎÒÃÇ | ¹ã¸æ·þÎñ | ±¾Õ¾¶¯Ì¬ | ÓÑÇéÁ´½Ó | ·¨ÂÉÉùÃ÷ | ·Ç·¨ºÍ²»Á¼ÐÅÏ¢¾Ù±¨  
    ¹¤¿ØÍø¿Í·þÈÈÏߣº0755-86369299
    °æȨËùÓÐ ¹¤¿ØÍø Copyright@ Gkong.com, All Rights Reserved