Ê×Ò³ - ÐÂÎÅ - ÕÐƸ - ÏÂÔØ - ²úÆ· - ³§ÉÌ - ·½°¸ - ÎÄÕª - Çó¹º - Õ¹ÀÀ
Ãâ·Ñ×¢²á µÇ¼ | ¹ã¸æ·þÎñ | ¿Í·þÖÐÐÄ
Öлª¹¤¿ØÍø ¡ú ¹¤¿Ø²úÆ· ¡ú ½»»»»ú6GK57461AA604AA0´ÙÏú
²úÆ·Ãû³Æ£º ½»»»»ú6GK57461AA604AA0´ÙÏú
ÐÍ ºÅ£º 6GK57461AA604AA0
¼Û ¸ñ£º 0.00
Æ· ÅÆ£º 1
 
Êղش˲úÆ·     ²é¿´ÊÕ²Ø

 

¶©»õÊý¾Ý

 

²úÆ·Ãû³Æ

¶©»õºÅ

SCALANCE W784-1

6GK5784-1AA30-2AA0

SCALANCE W784-1RR

6GK5784-1AA30-6AA0

SCALANCE W744-1

6GK5744-1AA30-2AA0

SCALANCE W746-1

6GK5746-1AA30-4AA0

SCALANCE W747-1

6GK5747-1AA30-6AA0

°²×°¹¤¾ß°ü MS 2

6GK5798-8MJ00-0AA0

¼¼ÊõÊý¾Ý

 

ÀàÐÍ

SCALANCE
W784-1¡¢W784-1RR

 SCALANCE
W744-1¡¢W746-1¡¢W747-1

´«ÊäËÙÂÊ

 

±ê×¼

 

ÎÞÏßµç

2.4 GHz ºÍ 5 GHz µÄ IEEE 802.11b/g£¬a/h

 

ʹÓà W784-1RR ½øÐпìËÙÂþÓÎ (iPCF)

ʹÓà W747-1RR ½øÐпìËÙÂþÓÎ (iPCF)

 

IEEE 802.11e (WMM)

 

 

 

½Ó¿Ú

 

ÎÞÏß½Ó¿Ú

1£¬Ã¿ÖÖÇé¿ö 8 ¸ö SSID (8 VLANs)

1

 

 

µçÆø½Ó¿Ú

1x RJ45 ²å×ù (10/100 Mbit/s£¬TP)

1x RJ45 ²å×ù (10/100 Mbit/s£¬TP)£¬ÔÊÐí×î¶àÁ¬½Ó 8 ¸öÉ豸 (W744-1 ½öÒ»¸öÉ豸)

ÌìÏß

ͨ¹ý R-SMA µÄÍⲿÌìÏß

µçÔ´µçѹ

µ½ IEEE 802.3af µÄ PoE  ºÍ  18 - 24V DC

¹¦ÂÊÏûºÄ

4W

·À»¤µÈ¼¶

IP30

ÔÊÐíµÄÍⲿÌõ¼þ

 

»·¾³Î¶È

 

¹¤×÷ÆÚ¼ä

-20 ¡ãC µ½ +60 ¡ãC (½á¶)

´æ´¢ÆÚ¼ä

-30 ¡ãC µ½ +70 ¡ãC

ÔËÊäÆÚ¼ä

-30 ¡ãC µ½ +70 ¡ãC

25¡ãC ʱµÄÏà¶Ôʪ¶È

10 - 90%

»úеÉè¼Æ

 

¿í

100mm

¸ß

225mm

³¤

20mm

°²×°

ǽÃæ°²×°£»Ê¹ÓÿÉÑ¡°²×°¹¤¾ß£º±ê×¼µ¼¹ì£¬S7-300 µ¼¹ì

¾»ÖØ

0.291kg

6. Óû§ÊÜÒæ 

- ½ÓÏß°å°²×°½ÚÊ¡¿Õ¼ä

- ʹÓÃ×Ô¶¯»¯É豸ºÍ¹¤ÒµÖÕ¶ËÉ豸µÄÎÞÏßͨѶ¿ÉÒÔ·ÃÎÊÒƶ¯Ä¿±ê

- ÔÚÐźŸ²¸ÇÇøÄÚµÄÇøÓòÍøÂ绥Á¬ (ÂþÓÎ)£¬ÊµÏÖÒƶ¯Öն˵¥ÔªµÄËæÒâ°²×°

- Ó¦ÓÃÔÚÄÑÒÔ·ÃÎʵÄÇøÓòÄÚ¡£ÕâÑù¿ÉÒÔ±ÜÃâÐèÒª¶îÍâµÄ¹¹½¨´ëÊ©

- ÈκÎʱ¼äºÍµØµã¾ù¿É»ñµÃÐÅÏ¢ÒÔ¼°ÊµÏÖÐ޸ŦÄÜ£¬¼ÓËÙÁË´¦ÀíÁ÷³Ì

- Áé»îʵÏÖϵͳµÄÖØв¼Öã¬È磺¿ìËÙ¸ü»»¿ØÖƵصã»òÔÚ³µ¼ä½øÐпÉÄܵÄÀ©Õ¹/¸ÄÔì×é̬

- ´Ó¹ÜÀíºÍ¿ØÖƼ¶µ½ÏÖ³¡¼¶µÄͳһÍøÂ绥Á¬£¬¼õÉÙÁ˲㼶֮¼äÍø¹ØµÄ¿ªÏú²¢½ÚÊ¡ÁËÖظ´ÑµÁ·µÄ´ú¼Û

- ÎÞÄ¥Ë𣭽ÚÊ¡Á˲åÈëʽÁ¬½ÓÆ÷¡¢À­Á´¡¢Ì¼Ë¢¡¢»¬¶¯´¥µã»òÈÆÏß»ú¹¹µÄά»¤ºÍάÐÞ·ÑÓÃ

- ʹÓà SINEMA E ¹æ»®¡¢·ÂÕæºÍ×é̬Èí¼þ£¬¼õÉÙÁËͨѶÍøÂçµÄ°²×°¹¤×÷£¬ÊµÏÖгµ¼ä²¿ÃŵĿìËÙÆô¶¯

- ¿ÉÒÔ×ÔÓÉ·ÃÎÊ 2.4 GHz ƵÂʲ¨¶Î£¬Òò´Ë²»ÔÙÐèÒªÐí¿É·ÑÓá£ÔÚ 5 GHz ƵÂʲ¨¶ÎÇé¿öÏ£¬±ØÐë×¢Òâµ±µØ¹æÕÂ

- Ó¦ÓÃÎÞÏß´«Êä¿É·ÀÖ¹ÒòÇ¿µÄÕñ¶¯»òÎÛȾ¶øµ¼ÖµĽӴ¥ÖжÏ

- ÔÚÎÞÏßÏß·ÖпÉÔ¤²âÊý¾ÝÁ÷Á¿ (È·¶¨ÐÔ) ºÍ¶¨ÒåµÄÏìӦʱ¼ä

- ¿É¿¿µÄÎÞÏßÁ¬½Ó£¬È磺ʹÓÃÈßÓàÁ¬½Ó¡¢×Ô¶¯ÂþÓΡ¢µ½¹¤ÒµÒÔÌ«ÍøµÄÎÞÏßÁ´½ÓÖÐ¶Ï (Ç¿ÖÆÂþÓÎ)£¬ÎÞÏßÏß·µÄÑ­»·¼àÊÓ (Á´½Ó¼ì²é) »ò IP Á¬½Ó¼àÊÓ (IP »îÔ¾)

- ¸ßµÄͶ×Ê°²È«ÐÔ£¬ÒòΪËùÓвúÆ·¶¼×ñ´ÓÈ«ÇòÈÏ¿ÉµÄ IEEE 802.11 ±ê×¼£¬²¢¿ÉÓÃÓÚ 2.4 GHz ºÍ 5 GHz ͨѶ

7. ÆäËü 

ÍƼöµÄÒÔÌ«ÍøÍ­ÖʵçÀ£º

¡¤         IE FC TP ±ê×¼µçÀ GP 2 x 2 (ÀàÐÍ A)£¬¶©»õºÅ£º6XV1 840-2AH10

¡¤         IE TP ¿¹Å¤µçÀ 2 x 2 (ÀàÐÍ C)£¬¶©»õºÅ£º6XV1 870-2F

¡¤         IE FC TP ÍÏÒ·µçÀ 2 x 2 (ÀàÐÍ C)£¬¶©»õºÅ£º6XV1 840 3AH10

ÎÞÏßÈÏÖ¤£º

Ä¿Ç°£¬SCALANCE W-784¡¢W744-1¡¢W746-1 ºÍ W747-1 ¾ßÓÐÒÔϹú¼ÒµÄÎÞÏßÈÏÖ¤£º
°ÂµØÀû (AT)¡¢±ÈÀûʱ (BE)¡¢±£¼ÓÀûÑÇ (BG)¡¢½Ý¿Ë¹²ºÍ¹ú (CZ)¡¢µ¤Âó (DK)¡¢·ÒÀ¼ (FI)¡¢·¨¹ú (FR)¡¢µÂ¹ú (DE)¡¢Ï£À° (GR)¡¢ÐÙÑÀÀû (HU)¡¢±ùµº (IS)¡¢°®¶ûÀ¼ (IE)¡¢Òâ´óÀû (IT)¡¢ÁÐÖ§¶ØÊ¿µÇ (LI)¡¢Â¬É­±¤ (LU)¡¢ºÉÀ¼ (NL)¡¢Å²Íþ (NO)¡¢²¨À¼ (PL)¡¢ÆÏÌÑÑÀ (PT)¡¢ÂÞÂíÄáÑÇ (RO)¡¢Ë¹Âå·¥¿Ë¹²ºÍ¹ú (SK)¡¢Ë¹ÂåÎÄÄáÑÇ (SI)¡¢Î÷°àÑÀ (ES)¡¢Èðµä (SE)¡¢ÈðÊ¿ (CH)¡¢Ó¢¹ú (GB)

½ÓÏÂÀ´µÄ¼¸¸öÔ½«»áÓиü¶àµÄÈÏÖ¤¡£

  

¹Ì¼þ£º

SCALANCE W-784 ½ÓÈëµãºÍ SCALANCE W744-1¡¢W746-1 ºÍ W747-1 ÒÔÌ«Íø¿Í»§¶ËÄ£¿é·¢»õʱÒѾ­Ê¹ÓÃÁË×îеĹ̼þ°æ±¾ V3.315£¬Óë V3.1.26 °æ±¾Ïà±È£¬¸Ã¹Ì¼þ°æ±¾Ôö¼ÓÁËһЩ¹¦ÄÜ¡£

й¦ÄÜÓУº

- ´øÓÐÓÃÓÚÎÞÏß·Ö²¼ÏµÍ³ (WDS) µÄ WPA-PSK£¬Ôö¼ÓÁË°²È«ÐÔÄÜ 

- ÏÖÔÚÒ²¿ÉÒÔΪ"new client logged-in at access point¡°Ê¼þÉú³É SNMP trap

- ¼õÉÙÁËÀäÆô¶¯Çé¿öϵÄÆô¶¯Ê±¼ä

SCALANCE W-784¡¢W744-1¡¢W746-1 ºÍ W747-1 ¼È¿ÉÒÔʹÓÃÍøÒ³ä¯ÀÀÆ÷ (»ùÓÚÍøÒ³µÄ¹ÜÀí¹¤¾ß) ×é̬£¬Ò²¿ÉÒÔʹÓà SINEMA E 2006 SP2 ×é̬¡£¹ØÓÚ SINEMA E 2006 SP2 µÄ¸ü¶àÐÅÏ¢

ÌìÏߺ͸½¼þ£º

SCALANCE W-784¡¢W744-1¡¢W746-1 ºÍ W747-1 ²úÆ·½ö·¢²¼ÓÃÓÚÓëÏÂÃæµÄ SIMATIC NET ÌìÏߺ͸½¼þÒ»ÆðʹÓãº


ÌìÏߣº

  • ANT795-6MN
  • ANT795-4MS
  • ANT792-6MN
  • ANT793-6MN
  • ANT795-6DN
  • ANT792-8DN
  • ANT793-8DN
  • ANT792-4DN
  • ANT793-4MN

±ÜÀ×£º

  • LP798-1N

µçÀ (RCoax ϵÁÐ)£º

  • N-Connect Male/Male Flexible Á¬½ÓµçÀ£º1m¡¢2m¡¢5m¡¢10m
  • N-Connect/R-SMA Male/Male Flexible Á¬½ÓµçÀ£º1m¡¢2m¡¢5m¡¢10m
  • R-SMA/SMA Male/Male Flexible Á¬½ÓµçÀ£º0.3m¡¢2m

Panel Feedthrough (RCoax ϵÁÐ)£º

  • N-Connect/SMA Female/Female Panel Feedthrough
 


¹«Ë¾¼ò½é
²úƷĿ¼
¹©Ó¦ÐÅÏ¢

¹«Ë¾Ãû³Æ£º ÄϾ©Àʳۼ¯ÍÅ»úµçÓÐÏÞ¹«Ë¾Î人·Ö¹«Ë¾
µç »°£º 0 15827199648 / ÌÀ¶ä
´« Õ棺 027-86783007-802
µØ Ö·£º Îä²ýÇøÎäçó·456ºÅÐÂʱ´úÉÌÎñÖÐÐÄ£¨Öн¨Èý¾Ö£©Ö÷Â¥4²ã
ÓÊ ±à£º 430000
Ö÷ Ò³£º http://www.langchi.com

¸Ã³§ÉÌÏà¹Ø²úÆ·£º
  • 24¸öµç¿Ú½»»»»úSCALANCE X124ÌؼÛ
  •  
  • ·ÇÍø¹ÜÐͽ»»»»úSCALANCE X104-2ÏÖ»õ
  •  
  • Íø¹ÜÐÍÎ÷ÃÅ×Ó½»»»»úSCALANCE X206-1LDÌؼÛ
  •  
  • µ¥Ä£¹âÏ˽»»»»úSCALANCE X212-2LDÌؼÛ
  •  
  • ú¿óÐÐҵרÓý»»»»úSCALANCE X414-3EÏÖ»õ
  •  
  • Î÷ÃÅ×Ó¹¤¿Ø»ú547ECO´úÀí-6AG4010-3AB12-0BX5
  •  
  • EC0Î÷ÃÅ×Ó¹¤¿Ø»ú6AG4010-3AB12-0BX5
  •  
  • ÏÖ»õ³öÊÛÎ÷ÃÅ×ÓÎÞÏß½»»»»ú6GK57441AA602AA0
  •  
  • ¶àÄ£½»»»»úSCALANCE X204-2ÏÖ»õ
  •  
  • ÕýÆ·¹©Ó¦Î÷ÃÅ×Ó½»»»»úSCALANCE X106-1
  •  
    ¸ü¶à²úÆ·...
      ¹ØÓÚÎÒÃÇ | ÁªÏµÎÒÃÇ | ¹ã¸æ·þÎñ | ±¾Õ¾¶¯Ì¬ | ÓÑÇéÁ´½Ó | ·¨ÂÉÉùÃ÷ | ·Ç·¨ºÍ²»Á¼ÐÅÏ¢¾Ù±¨  
    ¹¤¿ØÍø¿Í·þÈÈÏߣº0755-86369299
    °æȨËùÓÐ ¹¤¿ØÍø Copyright@ Gkong.com, All Rights Reserved