¼ò½é
Moxa EDS-P510A-8PoEϵÁÐÊÇǧÕ×PoE+Íø¹ÜÐÍÒÔÌ«Íø½»»»»ú±êÅä8¸ö¼æÈÝ10/100BaseT£¨X£©¡¢802.3af£¨PoE£©¼°802.3at (PoE+)µÄÒÔÌ«Íø¿ÚÒÔ¼°2¸öǧÕ××éºÏÒÔÌ«Íø¿Ú¡£EDS-P510A-8PoEÿ¸öPoE+¶Ë¿ÚÌṩ×î¸ß30WµÄµçÔ´£¬×î¸ß¿ÉÊä³ö36W ¸ø¹¤ÒµÉ豸£¬Èç¾ß±¸ÓêË¢¼°¼ÓÈÈÆ÷µÄ·À·çÓêIPÉãÏñÍ·¡¢¸ßÐÔÄÜÎÞÏßAP¼°¹¤Òµ¼¶IPµç»°¡£EDS-P510-8PoEÒÔÌ«Íø½»»»»ú¸ß¶ÈÁé»î£¬¶øÇÒSFP¹âÏ˶˿ڴ«ÊäÊý¾Ýµ½¿ØÖÆÖÐÐĵľàÀë¸ß´ï120¹«À²¢¾ßÓи߿¹µç´Å¸ÉÈÅÄÜÁ¦¡£EDS-P510-8PoEÖ§³Ö¶àÖÖ¹ÜÀí¹¦ÄÜ£¬°üÀ¨STP/RSTP¡¢TurboRing¡¢Turbo Chain¡¢PoEµçÔ´¹ÜÀí¡¢PoEÉ豸×Ô¶¯¼ì²â¡¢PoEµçÔ´Åų̡¢PoEÕï¶Ï¡¢IGMP¡¢VLAN¡¢QoS¡¢RMON¡¢´ø¿í¹ÜÀí¼°¶Ë¿Ú¾µÏñ¹¦ÄÜ¡£EDS-P510A-8PoEϵÁÐÊÇ×¨ÎªÌØÊâµÄÑϾþ»§ÍâÓ¦ÓÃËùÉè¼Æ£¬ËüµÄ3 KVÍø¿ÚÀËÓ¿±£»¤ÄÜÊÊÓ¦¶ñÁÓ»§Íâ»·¾³£¬ÒÔÈ·±£PoEϵͳ²»¼ä¶ÏµÄ¿É¿¿ÐÔ¡£
ÌØµãºÍÓÅÊÆ
- ÏȽøµÄPoE¹ÜÀí¹¦ÄÜ£¨PoE¶Ë¿ÚÉèÖá¢PD¹ÊÕϼì²é¡¢PoEµ÷¶È£©
- ÃüÁîÐнçÃæ£¨CLI£©¿É¿ìËÙÅäÖÃÖ÷ÒªÍø¹Ü¹¦ÄÜ
- IPv6 ReadyÈÏÖ¤£¨IPv6±ê־ίԱ»áÈÏÖ¤£©
- IEEE 1588 PTP V2£¨¾«ÃÜʱ¼äÐÒ飩ÓÃÓÚÓëÍøÂçͬ²½µÄ׼ȷʱ¼ä
- DHCP Opition 82ÓÃÓÚÒÔ²»Í¬²ßÂÔ·ÖÅäIPµØÖ·
- Ö§³ÖEtherNet/IPºÍModbus/TCP¹ÜÀí¼à¿ØÉ豸¹¦ÄÜ
- ¼æÈÝEtherNet/IPºÍPROFINETÐÒ飬½øÐÐ͸Ã÷Êý¾Ý´«Êä
- Ö§³ÖTurbo Ring, Turbo Chain£¨×ÔÓúʱ¼ä<20ms@250̨½»»»»ú£©ºÍRSTP/STPºÍMSTPÍøÂçÈßÓà
- IGMP snoopingºÍGMRPÓÃÓÚ¹ýÂ˹¤ÒµÒÔÌ«ÍøÐÒéÖеÄÁ÷Á¿
- Ö§³ÖPort-based VLAN, IEEE 802.1Q VLANºÍGVRPÐÒ飬¼òÒ×ÍøÂç¹æ»®
- Ö§³ÖQoS£¨IEEE 802.1p/1Q£©ºÍTOS/DiffServ£¬Ôö¼Ó¾ö¶¨ÐÔ
- Ö§³Ö¶Ë¿Ú¾ÛºÏ£¬×î´ó»¯ÀûÓôø¿í
- Ö§³ÖTACACS+£¬IEEE 802.1x£¬SNMP v3£¬HTTPSºÍSSH£¬¼ÓÇ¿ÍøÂ簲ȫÐÔ
- Ö§³Ö»ùÓÚMACµØÖ·µÄ¶Ë¿ÚËø¶¨£¬·ÀÖ¹·Ç·¨ÈëÇÖ
- Ö§³ÖSNMP V1/V2c/V3Õë¶Ô²»Í¬µÈ¼¶µÄÍøÂç¹ÜÀí
- ²ÉÓÃRMONÓÐЧÌáÉýÍøÂç¼à²âºÍÔ¤²âÄÜÁ¦
- Ö§³Ö´ø¿í¹ÜÀí£¬È·±£ÍøÂçÎȶ¨ÐÔ
- Ö§³Ö¶Ë¿Ú¾µÏñ¹¦ÄÜ£¬±ãÓÚÔÚÏßµ÷ÊÔ
- ͨ¹ýe-mailºÍ¼ÌµçÆ÷Êä³ö×Ô¶¯±¨¸æÒâÍâʼþ
¼¼Êõ²ÎÊý ±ê×¼£º
IEEE 802.3afÊÊÓÃÓÚPower-over-Ethernet
IEEE 802.3ÊÊÓÃÓÚ10BaseT
IEEE 802.3uÊÊÓÃÓÚ100BaseT(X)ºÍ100BaseFX
IEEE 802.3abÊÊÓÃÓÚ1000BaseT(X)
IEEE 802.3zÊÊÓÃÓÚ1000BaseX
IEEE 802.3xÊÊÓÃÓÚÁ÷Á¿¿ØÖÆ
IEEE 802.1D-2004ÊÊÓÃÓÚSpanning Tree Protocol
IEEE 802.1wÊÊÓÃÓÚRapid STP
IEEE 802.1sÊÊÓÃÓÚMultiple Spanning Tree Protocol
IEEE 802.1QÊÊÓÃÓÚVLAN Tagging
IEEE 802.1pÊÊÓÃÓÚClass of Service
IEEE 802.1XÊÊÓÃÓÚAuthentication
IEEE 802.3adÊÊÓÃÓÚPort Trunk with LACP
ÐÒ飺IGMPv1/v2£¬GMRP£¬GVRP£¬SNMPv1/v2c/v3£¬DHCP Server/Client£¬DHCP Option 66/67/82£¬BootP£¬TFTP£¬SNTP£¬SMTP£¬RARP£¬RMON£¬HTTP£¬HTTPS£¬Telnet£¬SSH£¬Syslog
EtherNet/IP£¬Modbus/TCP£¬SNMP Inform£¬LLDP£¬IEEE 1588 PTP V2£¬IPv6£¬NTP Server/Client
MIB£ºMIB-II£¬Ethernet-Like MIB£¬P-BRIDGE MIB£¬Q-BRIDGE MIB£¬Bridge MIB£¬RSTP MIB£¬RMON MIB Group 1£¬2£¬3£¬9
Á÷Á¿¿ØÖÆ£ºIEEE 802.3 xÁ÷Á¿¿ØÖÆ£¬±³Ñ¹Ê½Á÷¿Ø
½»»»»úÊôÐÔ ÓÅÏȼ¶¶ÓÁУº4
×î¶à¿ÉÓõÄVLANÊý£º64
VLAN ID·¶Î§£ºVID 1 ~ 4094
IGMP×飺256
MACµØÖ·±í´óС£º8 K
·â°ü»º³åÇø´óС£º1 Mbit ½Ó¿Ú ¹â¿Ú£º100/1000BaseSFP²å²Û
RJ45¶Ë¿Ú£º10/100BaseT(X)»ò10/100/1000BaseT(X) ×ÔÕì²â
PoE¹Ü½Å£ºV+£¬V+£¬V-£¬V-¶ÔÓ¦Õë½Å1£¬2£¬3£¬6 (Endspan£¬MDI Alternative A)
¿ØÖÆÌ¨£ºRS-232£¨RJ45Á¬½ÓÍ·£©
DIP¿ª¹Ø£ºTurbo Ring£¬Master£¬Coupler£¬Reserve
LEDָʾµÆ£ºPWR1£¬PWR2£¬FAULT£¬10/100/1000£¬10/100£¬MSTR/HEAD£¬CPLR/TAIL£¬PoE
±¨¾¯Í¨Öª£º1·¼ÌµçÆ÷Êä³ö£¬µçÁ÷¸ºÔØÄÜÁ¦0.5A @ 48 VDC
Êý×ÖÊäÈ룺1·ÊäÈ룬µç×Ó¸ôÀ룬¹²µØ
• ״̬¡°1¡±£º+13 ~ +30 V
• ״̬¡°0¡±£º-30 ~ +3 V
• ×î´óÊäÈëµçÁ÷£º8 mA
µçÔ´ÐèÇó ÊäÈëµçѹ£º48 (46 ~ 57 V) VDC£¬Ë«ÈßÓàÊäÈ루½¨ÒéÓÃÓÚPoE+Êä³öʱҪ´óÓÚ50 VDC£©
ÊäÈëµçÁ÷£º0.27 A @ 48 VDC (Á¬½ÓÊܵçÉ豸), 0.42 A @ 48 VDC(Á¬½Ó8̨ÊܵçÉ豸£¬µ«²»º¬ÊܵçÉ豸µçÔ´ÏûºÄ)*
¹ýµçÁ÷±£»¤£ºÌṩ
Á¬½Ó£ºÁ½¸ö¿É²å°Î2Õë½ÓÏß¶Ë×Ó
·´½Ó±£»¤£ºÌṩ
* µ±Ñ¡ÔñµçÔ´¹©Ó¦Ê±£¬Çë¼ì²éÊܵçÉ豸µçÁ¿ÏûºÄ
»úÐµÌØÐÔ Íâ¿Ç£ºIP30·À»¤µÈ¼¶£¬½ðÊôÍâ¿Ç
³ß´ç£º79.2 x 135 x 105 mm (3.12 x 5.31 x 4.13 in)
ÖØÁ¿£º1030g
°²×°£º¹ìµÀ°²×°£¬±Ú¹Òʽ°²×°£¨¿ÉÑ¡Ì×¼þ£©
¹¤×÷»·¾³ ¹¤×÷ζȣº
±ê×¼Ðͺţº-10 ~ 60 ¡ãC (14 ~ 140 ¡ãF)
¿íÎÂÐͺţº-40 ~ 75 ¡ãC (-40 ~ 167 ¡ãF)
´¢´æÎ¶ȣº-40 ~ 85 ¡ãC (-40 ~ 185 ¡ãF)
Ïà¶Ôʪ¶È£º5 ~ 95%£¨ÎÞÄý¶£©
°²¹æÈÏÖ¤ Safety£ºUL 508 £¨ÈÏÖ¤ÖУ©
EMI£ºFCC Part 15 Subpart B Class A£¬EN 55022 Class A
EMS£º
EN 61000-4-2 (ESD) Level 3£¬EN 61000-4-3 (RS) Level 3,
EN 61000-4-4 (EFT) Level 3£¬EN 61000-4-5 (Surge) Level 3,
EN 61000-4-6 (CS) Level 3£¬EN 61000-4-8
Traffic Control£ºNEMA-TS2
Rail Traffic£ºEN 50121-4
Shock£ºIEC 60068-2-27
Freefall£ºIEC 60068-2-32
Vibration£ºIEC 60068-2-6
×¢£ºÇëµÇ½MoxaÍøÕ¾£¬»ñÈ¡×îÐÂÈÏÖ¤ÐÅÏ¢¡£
MTBF£¨Æ½¾ùÎÞ¹ÊÕÏʱ¼ä£© ʱ¼ä£ºTBD
Êý¾Ý¿â£ºTelcordia (Bellcore)£¬GB
±£ÐÞ ±£ÐÞÆÚ£º5Äê