Ê×Ò³ - ÐÂÎÅ - ÕÐÆ¸ - ÏÂÔØ - ²úÆ· - ³§ÉÌ - ·½°¸ - ÎÄÕª - Çó¹º - Õ¹ÀÀ
Ãâ·Ñ×¢²á µÇ¼ | ¹ã¸æ·þÎñ | ¿Í·þÖÐÐÄ
Öлª¹¤¿ØÍø ¡ú ¹¤¿Ø²úÆ· ¡ú Î÷ÃÅ×ÓCPUÄ£¿é315-2DP
²úÆ·Ãû³Æ£º Î÷ÃÅ×ÓCPUÄ£¿é315-2DP
ÐÍ ºÅ£º 6ES7315-2AH14-0AB0
¼Û ¸ñ£º
Æ· ÅÆ£º
 
Êղش˲úÆ·     ²é¿´ÊÕ²Ø

Î÷ÃÅ×ÓCPUÄ£¿é315-2DP   Î÷ÃÅ×ÓCPU315-2DP¿É±à³Ì¿ØÖÆÆ÷    Î÷ÃÅ×ÓCPUÄ£¿é315-2DPÖÐÑë´¦ÀíÆ÷Ä£×é

ÏúÊÛ¶©»õºÅ£º

6ES7 315-2AG10-0AB0 

6ES7 315-2AH14-0AB0

 

CPU 315-2 DP °²×°ÓУº
΢´¦ÀíÆ÷;
´¦ÀíÆ÷¶ÔÿÌõ¶þ½øÖÆÖ¸ÁîµÄ´¦Àíʱ¼ä´óԼΪ 50 ns£¬Ã¿¸ö¸¡µãÔ¤ËãµÄʱ¼äΪ 0.45 µs¡£
256 KB ¹¤×÷´æ´¢Æ÷£¨Ï൱ÓÚ´óÔ¼ 85 K ÌõÖ¸Á£»
ÓëÖ´ÐгÌÐò¶ÎÏà¹ØµÄ´óÈÝÁ¿¹¤×÷´æ´¢Æ÷¿ÉÒÔΪÓû§³ÌÐòÌṩ×ã¹»µÄ¿Õ¼ä¡£×÷Ϊ³ÌÐò×°ÔØ´æ´¢Æ÷µÄ΢ÐÍ´æ´¢¿¨£¨×î´óΪ 8 MB£©Ò²ÔÊÐí½«¿ÉÒÔÏîÄ¿£¨°üÀ¨·ûºÅºÍ×¢ÊÍ£©±£´æÔÚ CPU ÖС£×°ÔØ´æ´¢Æ÷»¹¿ÉÓÃÓÚÊý¾Ý¹éµµºÍÅä·½¹ÜÀí¡£
Áé»îµÄÀ©Õ¹ÄÜÁ¦;
¶à´ï 32 ¸öÄ£¿é£¬£¨4ÅŽṹ£©
MPI¶àµã½Ó¿Ú;
¼¯³ÉµÄ MPI ½Ó¿Ú×î¶à¿ÉÒÔͬʱ½¨Á¢Óë S7-300/400 »ò±à³ÌÉ豸¡¢PC¡¢OP µÄ 16 ÌõÁ¬½Ó¡£ÔÚÕâЩÁ¬½ÓÖУ¬Ê¼ÖÕΪ±à³ÌÆ÷ºÍ OP ·Ö±ðÔ¤ÁôÒ»¸öÁ¬½Ó¡£Í¨¹ý“È«¾ÖÊý¾ÝͨѶ”£¬MPI¿ÉÒÔÓÃÀ´½¨Á¢×î¶à16¸öCPU×é³ÉµÄ¼òµ¥ÍøÂç¡£
PROFIBUS DP ½Ó¿Ú:
´øÓÐ PROFIBUS DP Ö÷/´Ó½Ó¿ÚµÄ CPU 315-2 DP ¿ÉÒÔÓÃÀ´½¨Á¢¸ßËÙ¡¢Ò×Óõķֲ¼Ê½×Ô¶¯»¯ÏµÍ³¡£¶ÔÓû§À´Ëµ,·Ö²¼Ê½I/Oµ¥Ôª¿É×÷Ϊһ¸ö¼¯ÖÐʽµ¥ÔªÀ´´¦Àí(ÏàͬµÄ×é̬¡¢±àÖ·ºÍ±à³Ì).
È«ÃæÖ§³Ö PROFIBUS DP V1 ±ê×¼¡£ËüÌá¸ßÁË DP V1 ±ê×¼´ÓÕ¾µÄÕï¶ÏºÍ²ÎÊý»¯ÄÜÁ¦¡£
¿ÚÁî±£»¤;
Óû§³ÌÐòʹÓÃÃÜÂë±£»¤£¬¿É·ÀÖ¹·Ç·¨·ÃÎÊ¡£
Õï¶Ï»º³å;
Õï¶Ï»º³åÇøÖпɴ洢×îºó 500 ¸ö´íÎóºÍÖжÏʼþ£¬ÆäÖÐµÄ 100 ¸öʼþ¿ÉÒÔ³¤ÆÚ±£Áô¡£
Ãâά»¤µÄÊý¾Ýºó±¸;
Èç¹ûµçÔ´Öжϣ¬CPU ½«ËùÓÐÊý¾Ý£¨×î´ó 128 KB£©×Ô¶¯Ð´µ½ SIMATIC ΢ÐÍ´æ´¢¿¨£¨MMC ¿¨£©ÉÏ£¬´Ó¶øÊ¹Êý¾Ý¿ÉÒÔÔÚµçѹ»Ö¸´ºóÔÙ´ÎʹÓã¬ÇÒ²»»á·¢Éú¸Ä±ä¡£
¿É²ÎÊý»¯µÄÌØÐÔ
¿ÉÒÔʹÓà STEP 7 ¶Ô S7 µÄ×é̬¡¢ÊôÐÔÒÔ¼°CPUµÄÏìÓ¦½øÐвÎÊýÉèÖãº
MPI¶àµã½Ó¿Ú;
¶¨ÒåÕ¾µØÖ·
ÖØÆô¶¯/Ñ­»·Ê±¼äÌØÐÔ£»
×î´óÑ­»·Ê±¼äÒÔ¼°¸ºÔØÏÞÖÆ£¬ÒÔ¼°×Ô¼ì²â¹¦ÄÜ
ʱÖÓ´æ´¢Æ÷£»
É趨µØÖ·
·À»¤µÈ¼¶£»
¶¨Òå³ÌÐòºÍÊý¾ÝµÄ·ÃÎÊȨÏÞ
ϵͳÕï¶Ï£»
¶¨ÒåÕï¶Ï±¨¾¯µÄ´¦ÀíºÍ·¶Î§
¿´ÃŹ·Öжϣ»
ÖÜÆÚÉ趨
ʱÖÓÖжÏ;
É趨ÆðʼÈÕÆÚ¡¢Æðʼʱ¼äºÍ¼ä¸ôÖÜÆÚ
PROFIBUS DP Ö÷Õ¾/´ÓÕ¾½Ó¿Ú;
Óû§¶¨Òå·Ö²¼Ê½ I/O µØÖ·
ÏÔʾ¹¦ÄÜÓëÐÅÏ¢¹¦ÄÜ
״̬ºÍ¹ÊÕÏָʾ£»
LED ָʾӲ¼þ¡¢±à³Ì¡¢Ê±¼ä¡¢I/O¡¢µç³ØºÍ×ÜÏß´íÎóÒÔ¼°²Ù×÷״̬£¨Èç RUN£¨ÔËÐУ©¡¢STOP£¨Í£Ö¹£©ºÍÆô¶¯£©¡£
²âÊÔ¹¦ÄÜ£»
¿ÉʹÓñà³ÌÆ÷ÏÔʾ³ÌÐòÖ´Ðйý³ÌÖеÄÐźÅ״̬£¬¿ÉÒÔ²»Í¨¹ýÓû§³ÌÐò¶øÐ޸Ĺý³Ì±äÁ¿£¬ÒÔ¼°Êä³ö¶ÑÕ»ÄÚÈÝ¡£
ÐÅÏ¢¹¦ÄÜ£»
Äú¿ÉÒÔʹÓñà³ÌÆ÷ÒÔ´¿Îı¾µÄÐÎʽ»ñÈ¡ CPU ´æ´¢ÈÝÁ¿ºÍ²Ù×÷ģʽ¡¢¹¤×÷´æ´¢Æ÷ºÍ×°ÔØ´æ´¢Æ÷µÄµ±Ç°ÀûÓÃÂÊÒÔ¼°µ±Ç°Ñ­»·Ê±¼äºÍÕï¶Ï»º³åÇøÄÚÈݵÄÏà¹ØÐÅÏ¢¡£

 

 

6ES7 315-2AH14-0AB0

Ò»°ãÐÅÏ¢

 

Ó²¼þ²úÆ·ÐͺÅ

01

¹Ì¼þÐͺÅ

V3.3

¹¤³Ì×é̬

 

  • ±à³ÌÈí¼þ°ü

STEP 7 V5.5 + SP1 »ò¸ü¸ß°æ±¾£¬»ò STEP7 V5.2 + SP1 »ò¸ü¸ß°æ±¾£¨´ø HSP 218£©

µçÔ´µçѹ

 

24 V DC

ÊäÈëµçÁ÷

 

µçÁ÷ÏûºÄ£¨¶î¶¨Öµ£©

850 mA

µçÁ÷ÏûºÄ£¨¿ÕÔØ£©£¬µäÐÍÖµ

150 mA

³å»÷µçÁ÷£¬µäÐÍÖµ

3.5 A

I²t

1 A²·s

¹¦ºÄ

 

¹¦ºÄ£¬µäÐÍÖµ

4.5 W

´æ´¢Æ÷

 

´æ´¢Æ÷ÀàÐÍ

ÆäËü

¹¤×÷´æ´¢Æ÷

 

  • ¼¯³É

256 kbyte

  • ¿ÉÀ©Õ¹

X

  • ÓÃÓÚ·ÇÒ×ʧÐÔÊý¾Ý¿éµÄ·ÇÒ×ʧÐÔ´æ´¢Æ÷µÄ´óС

128 kbyte

×°ÔØ´æ´¢Æ÷

 

  • ¿É²åÈë(MMC)

  • ¿É²åÈë(MMC)£¬×î´ó

8 Mbyte

  • ΢ÐÍ´æ´¢¿¨Êý¾Ý¹ÜÀí£¨×îºóÒ»´Î±à³Ìºó£©£¬×îСֵ

10 a

ºó±¸

 

  • Ìṩ

√£»Í¨¹ý MMC ±£Ö¤£¨Ãâά»¤£©

  • ÎÞµç³Ø

√£»³ÌÐòºÍÊý¾Ý

CPU ´¦Àíʱ¼ä

 

λ²Ù×÷£¬µäÐÍ

0.05 µs

×Ö²Ù×÷£¬µäÐÍ

0.09 µs

¶¨µãÊýÔËË㣬µäÐÍ

0.12 µs

¸¡µãÊýÔËË㣬µäÐÍ

0.45 µs

CPU ¿é

 

¿éÊýÁ¿£¨×ÜÊý£©

1024£»£¨Êý¾Ý¿é¡¢º¯Êý¡¢º¯Êý¿é£©£»¿Éͨ¹ýʹÓÃµÄ MMC À´¼õÉٿɼÓÔØ¿éµÄ×î´óÊýÁ¿¡£

DB

 

  • ÊýÁ¿£¬×î´ó

1024£»ÊýÖµ·¶Î§£º 1 µ½ 16000

  • ÈÝÁ¿£¬×î´ó

64 KB

FB

 

  • ÊýÁ¿£¬×î´ó

1024£»ÊýÖµ·¶Î§£º 0 µ½ 7999

  • ÈÝÁ¿£¬×î´ó

64 KB

FC

 

  • ÊýÁ¿£¬×î´ó

1024£»ÊýÖµ·¶Î§£º 0 µ½ 7999

  • ÈÝÁ¿£¬×î´ó

64 KB

OB

 

  • ÈÝÁ¿£¬×î´ó

64 KB

ǶÌ×Éî¶È

 

  • ÿ¸öÓÅÏȼ¶

16

  • ÔÚÒ»¸ö´íÎó OB Öи½¼Ó

4

¼ÆÊýÆ÷¡¢¶¨Ê±Æ÷¼°Æä±£³ÖÐÔ

 

S7 ¼ÆÊýÆ÷

 

  • ÊýÁ¿

256

  • ±£³ÖÐÔ

 

    • ¿Éµ÷½Ú

    • ÏÂÏÞ

0

    • ÉÏÏÞ

255

    • Ô¤ÖÃ

Z0 ¡« Z7

  • ¼ÆÊý·¶Î§

 

    • ÏÂÏÞ

0

    • ÉÏÏÞ

999

IEC ¼ÆÊýÆ÷

 

  • Ìṩ

  • ÐͺÅ

SFB

  • ÊýÁ¿

²»ÏÞ£¨Ö»È¡¾öÓÚ RAM ÈÝÁ¿£©

S7 ¶¨Ê±Æ÷

 

  • ÊýÁ¿

256

  • ±£³ÖÐÔ

 

    • ¿Éµ÷½Ú

    • ÏÂÏÞ

0

    • ÉÏÏÞ

255

    • Ô¤ÖÃ

ÎÞ±£³ÖÐÔ

  • ʱ¼ä·¶Î§

 

    • ÏÂÏÞ

10 ms

    • ÉÏÏÞ

9 990 s

IEC ¶¨Ê±Æ÷

 

  • Ìṩ

  • ÐͺÅ

SFB

  • ÊýÁ¿

²»ÏÞ£¨Ö»È¡¾öÓÚ RAM ÈÝÁ¿£©

Êý¾ÝÇø¼°Æä±£³ÖÐÔ

 

±£³ÖÊý¾ÝÇøÓò£¬×ܹ²

È«²¿£¬×î´ó 128 KB

±êÖ¾

 

  • ÊýÁ¿£¬×î´ó

2 048 byte

  • ¿É±£³Ö

√£»MB 0 – MB 2047

  • Ô¤Éè±£³ÖÐÔ

MB 0 - MB 15

  • ʱÖÓ´æ´¢Æ÷µÄÊýÁ¿

8; 1¸ö´æ´¢×Ö½Ú

Êý¾Ý¿é

 

  • ±£³ÖÐԿɵ÷½Ú

√£»Í¨¹ý DB ÉϵķDZ£³ÖÐÔ

  • Ô¤Éè±£³ÖÐÔ

¾Ö²¿Êý¾Ý

 

  • ÿ¸öÓÅÏȼ¶£¬×î´ó

32 KB£»Ã¿¸ö¿é×î´ó 2 KB

µØÖ·Çø

 

I/O µØÖ·Çø

 

  • ÊäÈë

2 048 byte

  • Êä³ö

2 048 byte

  • ÆäÖзֲ¼Ê½

 

    • ÊäÈë

2 048 byte

    • Êä³ö

2 048 byte

¹ý³ÌÓ³Ïñ

 

  • ÊäÈ룬¿Éµ÷½Ú

2 048 byte

  • Êä³ö£¬¿Éµ÷½Ú

2 048 byte

  • ĬÈÏÊäÈë

128 byte

  • ĬÈÏÊä³ö

128 byte

×Ó¹ý³ÌÓ³Ïñ

 

  • ×Ó¹ý³ÌÓ³ÏñµÄÊýÁ¿£¬×î´ó

1

Êý×ÖÁ¿Í¨µÀ

 

  • ÊäÈë

16 384

  • Êä³ö

16 384

  • ÖÐÑëÇøµÄÊäÈëͨµÀ

1 024

  • ÖÐÑëÇøµÄÊä³öͨµÀ

1 024

Ä£ÄâÁ¿Í¨µÀ

 

  • ÊäÈë

1 024

  • Êä³ö

1 024

  • ÖÐÑëÇøµÄÊäÈëͨµÀ

256

  • ÖÐÑëÇøµÄÊä³öͨµÀ

256

Ó²¼þÅäÖÃ

 

»ú¼Ü£¬×î´ó

4

ÿ¸ö»ú¼ÜµÄÄ£¿éÊýÁ¿£¬×î¶à

8

À©Õ¹É豸£¬×î¶à

3

DP Ö÷Õ¾µÄÊýÁ¿

 

  • ¼¯³É

1

  • ͨ¹ý CP

4

¿ÉÔËÐÐµÄ FM ºÍ CP ÊýÁ¿£¨ÍƼö£©

 

  • FM

8

  • CP£¬µãµ½µã

8

  • CP, LAN

10

ʱ¼ä

 

ʱÖÓ

 

  • Ó²¼þʱÖÓ£¨ÊµÊ±Ê±ÖÓ£©

  • µç³Øºó±¸ºÍ¿Éͬ²½

  • ÿÌìÎó²î£¬×î´ó

10 s£»µäÐÍÖµ£º2 s

  • ºó±¸Ê±¼ä

6 wk£»40 °C »·¾³Î¶ÈÏÂ

  • ¼ÓµçºóʱÖÓµÄÐÐΪ

µçÔ´¹Ø±ÕºóʱÖÓ¼ÌÐøÔËÐÐ

  • ºó±¸ÖÜÆÚ½áÊøºóʱÖÓµÄÐÐΪ

ʱÖÓÒÔ·¢Éú¹ÊÕÏʱµÄʱ¼ä¼ÌÐøÔËÐÐ

ÔËÐÐСʱ¼ÆÊýÆ÷

 

  • ÊýÁ¿

1

  • ÊýÁ¿/ÊýÁ¿·¶Î§

0

  • ÊýÖµ·¶Î§

0ÖÁ2^31 Сʱ£¨µ±Ê¹Óà SFC 101ʱ£©

  • ¼ÆÊý¼ä¸ô

1 Сʱ

  • ±£³ÖÐÔ

√£»ÔÚÿ´ÎÖØÆôʱ±ØÐëÖØÐÂÆô¶¯

ʱÖÓͬ²½

 

  • Ö§³Ö

  • ÖÁ MPI£¬Ö÷Õ¾

  • ÖÁ MPI£¬´ÓÕ¾

  • ÖÁ DP£¬Ö÷Õ¾

√;´øÓÐ DP ´ÓÕ¾£¬½ö´ÓվʱÖÓ

  • ÖÁ DP£¬´ÓÕ¾

  • ÔÚ AS ÉÏ£¬Ö÷Õ¾

  • ÔÚ AS ÉÏ£¬´ÓÕ¾

X

Êý×ÖÁ¿ÊäÈë

 

¿ª¹ØÁ¿ÊäÈë

0

Êý×ÖÁ¿Êä³ö

 

¿ª¹ØÁ¿Êä³ö

0

Ä£ÄâÁ¿ÊäÈë

 

Ä£ÄâÁ¿ÊäÈëµãÊý

0

Ä£ÄâÁ¿Êä³ö

 

Ä£ÄâÁ¿Êä³öµãÊý

0

½Ó¿Ú

 

USB ½Ó¿ÚÊýÁ¿

0

µÚ 1 ¸ö½Ó¿Ú

 

½Ó¿ÚÀàÐÍ

ÄÚÖÃ RS 485 ½Ó¿Ú

ÎïÀí

RS 485

¸ôÀë

X

½Ó¿ÚµçÔ´ (15-30 VDC)£¬×î´ó

200 mA

¹¦ÄÜÐÔ

 

  • MPI

  • DP Ö÷Õ¾

X

  • DP ´ÓÕ¾

X

  • µãµ½µãÁ¬½Ó

X

MPI

 

  • ×î´ó´«ÊäËÙÂÊ

187.5 kbit/s

  • ·þÎñ

 

    • ±à³ÌÆ÷/OP ͨÐÅ

    • ·ÓÉ

    • È«¾ÖÊý¾ÝͨÐÅ

    • S7 »ù±¾Í¨ÐÅ

    • S7 ͨÐÅ

√£»½ö·þÎñÆ÷£¬ÔÚÒ»²à×é̬

    • S7 ͨÐÅ£¬×÷Ϊ¿Í»§¶Ë

X

    • S7 ͨÐÅ£¬×÷Ϊ·þÎñÆ÷

µÚ 2 ¸ö½Ó¿Ú

 

½Ó¿ÚÀàÐÍ

ÄÚÖÃ RS 485 ½Ó¿Ú

ÎïÀí

RS 485

¸ôÀë

½Ó¿ÚµçÔ´ (15-30 VDC)£¬×î´ó

200 mA

¹¦ÄÜÐÔ

 

  • MPI

X

  • DP Ö÷Õ¾

  • DP ´ÓÕ¾

  • ±¾µØ¹¤×÷ÍøÂç

X

DP Ö÷Õ¾

 

  • ×î´ó´«ÊäËÙÂÊ

12 Mbit/s

  • DP ´ÓÕ¾µÄÊýÁ¿£¬×î´ó

124£»Ã¿¸öÕ¾

  • ·þÎñ

 

    • ±à³ÌÆ÷/OP ͨÐÅ

    • È«¾ÖÊý¾ÝͨÐÅ

X

    • S7 »ù±¾Í¨ÐÅ

√£»Ö»ÄÜÊÇ I ¿é

    • S7 ͨÐÅ

√£»½ö·þÎñÆ÷£¬ÔÚÒ»²à×é̬

    • S7 ͨÐÅ£¬×÷Ϊ¿Í»§¶Ë

X

    • S7 ͨÐÅ£¬×÷Ϊ·þÎñÆ÷

    • Ö§³ÖµÈ¾àÀëģʽ

    • µÈʱͬ²½Ä£Ê½

√£»OB 61

    • SYNC/FREEZE

    • DP ´ÓÕ¾µÄʹÓÃ/²»Ê¹ÓÃ

    • ¿ÉÒÔͬʱ¼¤»î/È¡Ïû¼¤»îµÄ DP ´ÓÕ¾ÊýÁ¿£¬×î´ó

8

    • DPV1

  • µØÖ·Çø

 

    • ÊäÈ룬×î´ó

2 048 byte

    • Êä³ö£¬×î´ó

2 048 byte

  • ÿ¸ö DP ´ÓÕ¾µÄÓû§Êý¾Ý

 

    • ÊäÈ룬×î´ó

244 byte

    • Êä³ö£¬×î´ó

244 byte

DP ´ÓÕ¾

 

  • GSD Îļþ

×îÐ嵀 GSD Îļþ¿ÉÒÔ´ÓÒÔϵØÖ·»ñµÃ£ºhttp://www.siemens.de/profibus-gsd

  • ×î´ó´«ÊäËÙÂÊ

12 Mbit/s

  • ×Ô¶¯ËÑË÷²¨ÌØÂÊ

√£»½öÔÚ½Ó¿ÚÎÞЧʱÊÊÓÃ

  • µØÖ·Çø£¬×î´ó

32

  • ÿ¸öµØÖ·ÇøµÄÓû§Êý¾Ý£¬×î´ó

32 ×Ö½Ú

  • ·þÎñ

 

    • ±à³ÌÆ÷/OP ͨÐÅ

    • È«¾ÖÊý¾ÝͨÐÅ

X

    • S7 »ù±¾Í¨ÐÅ

X

    • S7 ͨÐÅ

√£»½ö·þÎñÆ÷£¬ÔÚÒ»²à×é̬

    • S7 ͨÐÅ£¬×÷Ϊ¿Í»§¶Ë

X

    • S7 ͨÐÅ£¬×÷Ϊ·þÎñÆ÷

    • Ö±½ÓÊý¾Ý½»»»£¨´ÓÕ¾ºÍ´ÓվͨÐÅ£©

    • DPV1

X

  • ´«ËÍ´æ´¢Æ÷

 

    • ÊäÈë

244 byte

    • Êä³ö

244 byte

µÈʱͬ²½Ä£Ê½

 

ͬ²½²Ù×÷£¨Ò»Ö±Í¬²½ÖÁ¶Ë×Ó£©

ͨÐŹ¦ÄÜ

 

±à³ÌÆ÷/OP ͨÐÅ

Êý¾Ý¼Ç¼·ÓÉ

È«¾ÖÊý¾ÝͨÐÅ

 

  • Ö§³Ö

  • GD »·ÊýÁ¿£¬×î´óÖµ

8

  • GD °üÊýÁ¿£¬×î´óÖµ

8

  • GD °üÊýÁ¿£¬·¢ËÍÆ÷£¬×î´ó

8

  • GD °üÊýÁ¿£¬½ÓÊÕÆ÷£¬×î´ó

8

  • GD°üµÄ´óС£¬×î´ó

22 byte

  • GD °ü´óС£¨ÆäÖÐÒ»ÖÂÐԵģ©£¬×î´ó

22 byte

S7 »ù±¾Í¨ÐÅ

 

  • Ö§³Ö

  • ÿ¸ö×÷ÒµµÄÓû§Êý¾Ý£¬×î´ó

76 byte

  • ÿ¸ö×÷ÒµµÄÓû§Êý¾Ý£¨ÆäÖÐÒ»ÖÂÐÔÊý¾Ý£©£¬×î´ó

76 ×Ö½Ú£»76 ×Ö½Ú£¨´ø X_SEND »ò X_RCV£©£»64 ×Ö½Ú£¨´ø X_PUT »ò X_GET£¬×÷Ϊ·þÎñÆ÷£©

S7 ͨÐÅ

 

  • Ö§³Ö

  • ×÷Ϊ·þÎñÆ÷

  • ×÷Ϊ¿Í»§¶Ë

√£»Í¨¹ý CP ºÍ¿É¼ÓÔØµÄ¹¦ÄÜ¿é

  • ÿ¸ö×÷ÒµµÄÓû§Êý¾Ý£¬×î´ó

180 ×Ö½Ú£»²ÉÓà PUT/GET

  • ÿ¸ö×÷ÒµµÄÓû§Êý¾Ý£¨ÆäÖÐÒ»ÖÂÐÔÊý¾Ý£©£¬×î´ó

240 ×Ö½Ú£»×÷Ϊ·þÎñÆ÷

S5 ¿É¼æÈÝͨÐÅ

 

  • Ö§³Ö

√£»Í¨¹ý CP ºÍ¿É¼ÓÔØµÄ FC

Á¬½ÓÊýÁ¿

 

  • È«²¿

16

S7 ±¨ÎŦÄÜ

 

±¨ÎŦÄÜ¿ÉÒԵǼվµÄÊýÁ¿£¬×î¶à

16£»È¡¾öÓÚΪ PG/OP ºÍ S7 »ù±¾Í¨ÐÅËù×é̬µÄÁ¬½Ó

¹ý³ÌÕï¶Ï±¨ÎÄ

¿Éͬʱ¼¤»îµÄ Alarm-S ¿é£¬×î¶à

300

µ÷ÊÔ¹¦ÄÜ

 

״̬¿é

√£»×î¶à 2 ¸ö£¬Í¬Ê±

µ¥²½ÔËÐÐ

¶ÏµãÊýÁ¿

4

״̬/¿ØÖÆ

 

  • ״̬/¿ØÖƱäÁ¿

  • ±äÁ¿

ÊäÈë¡¢Êä³ö¡¢Î»´æ´¢Æ÷¡¢DB¡¢¶¨Ê±Æ÷¡¢¼ÆÊýÆ÷

  • ±äÁ¿µÄÊýÁ¿£¬×î¶à

30

  • ÆäÖÐ״̬±äÁ¿£¬×î¶à

30

  • ÆäÖпØÖƱäÁ¿£¬×î¶à

14

Ç¿ÖÆ

 

  • Ç¿ÖÆ

  • Ç¿ÖÆ£¬±äÁ¿

ÊäÈ룬Êä³ö

  • ±äÁ¿µÄÊýÁ¿£¬×î¶à

10

Õï¶Ï»º³åÇø

 

  • Ìṩ

  • ÊäÈëÊýÁ¿£¬×î´ó

500

    • ¿Éµ÷½Ú

X

    • ·ÀµçÔ´¹ÊÕÏ

100£»Ö»±£Áô×îºó 100 Ïî

  • ÔËÐÐÆÚ¼ä¿É¶ÁÌõÄ¿µÄÊýÁ¿£¬×î´óÖµ

 

    • ¿Éµ÷½Ú

√; 10 - 499

    • Ô¤ÖÃ

10

»·¾³Ìõ¼þ

 

¹¤×÷ζÈ

 

  • ×îСֵ

0 °C

  • ×î´óÖµ

60 °C

×é̬

 

±à³Ì

 

  • ÃüÁ

¼û“Ö¸Áî±í”

  • ǶÌ×¼¶

8

  • ±à³ÌÓïÑÔ

 

    • LAD

    • FBD

    • STL

    • SCL

    • CFC

    • GRAPH

    • HiGraph®

רÃÅ֪ʶ±£»¤

 

  • Óû§³ÌÐò±£»¤/ÃÜÂë±£»¤

  • ¿é¼ÓÃÜ

√£»´øÓÐ S7 ¿é¼ÓÃܹ¦ÄÜ

ÍâÐγߴç

 

¿í¶È

40 mm

¸ß¶È

125 mm

Éî¶È

130 mm

ÖØÁ¿

 

ÖØÁ¿£¬Ô¼

290 g

ÔÚS7-300£¬S7-400 ºÍ S7-1200 ÖÐʹÄÜ ad-hoc ģʽ
ÔÚ S7-300£¬S7-400 ºÍ S7-1200 ÖÐʹÄÜ ad-hoc ģʽ£¬ÐèÒª½« TRCV Ö¸ÁîµÄ LEN Òý½ÅÉèÖÃΪ“0”¡£
½ÓÊÕÇøÓòÓÉ DATA ²ÎÊýÖ¸¶¨¡£


ͼ 01

ÔÚ S7-1200 V2.0 ¼°ÒÔÉϰ汾ÖÐʹÄÜ ad-hoc ģʽ
ÔÚ S7-1200 V2.0 ¼°ÒÔÉϰ汾ÖÐʹÄÜ ad-hoc ģʽʱ£¬ÐèÒª½« TRCV Ö¸ÁîµÄ LEN Òý½ÅÉèΪ "65535 (0xFFFF)"¡£
½ÓÊÕÇøÓòÓÉ DATA ²ÎÊýÖ¸¶¨¡£


ͼ 02

ÔÚ S7-1500 ÖÐʹÄÜ ad-hoc ģʽ
TRCV Ö¸ÁîÔÚ S7-1500 ÖÐÓÐеÄÒþ²Ø²ÎÊý¡£µ±µ÷Óà TRCV Ö¸ÁîµÄʱºòÐèÒª´ò¿ª¿é²é¿´Òþ²Ø²ÎÊý¡£

 

 

 


¹«Ë¾¼ò½é
²úƷĿ¼
¹©Ó¦ÐÅÏ¢

¹«Ë¾Ãû³Æ£º ÉϺ£ÆôË®×Ô¶¯»¯¿Æ¼¼ÓÐÏÞ¹«Ë¾
µç »°£º 021 60641323 / ²·Éç°ï
ÊÖ»ú£º 18202105796
µØ Ö·£º ÉϺ£Ëɽ­Ð³ǺëÏè·58Ū195ºÅ
ÓÊ ±à£º 201620
Ö÷ Ò³£º http://

¸Ã³§ÉÌÏà¹Ø²úÆ·£º
  • Î÷ÃÅ×ÓS7-300PLC
  •  
  • Î÷ÃÅ×ÓS7-200PLC
  •  
  • Î÷ÃÅ×ÓS7-400PLC
  •  
  • Î÷ÃÅ×ÓS7-1200PLC
  •  
  • Î÷ÃÅ×ÓS7-1500PLC
  •  
  • Î÷ÃÅ×ÓWinCC¹¤³Ì×é̬Èí¼þ(TIA Portal)
  •  
  • Î÷ÃÅ×ÓWinCCϵͳ¼à¿ØÈí¼þ
  •  
  • Î÷ÃÅ×ÓSTEP 7 ±à³ÌÈí¼þ
  •  
  • Î÷ÃÅ×ÓS7-200CPU221
  •  
  • Î÷ÃÅ×ÓS7-200CPU222
  •  
    ¸ü¶à²úÆ·...
      ¹ØÓÚÎÒÃÇ | ÁªÏµÎÒÃÇ | ¹ã¸æ·þÎñ | ±¾Õ¾¶¯Ì¬ | ÓÑÇéÁ´½Ó | ·¨ÂÉÉùÃ÷ | ·Ç·¨ºÍ²»Á¼ÐÅÏ¢¾Ù±¨  
    ¹¤¿ØÍø¿Í·þÈÈÏߣº0755-86369299
    °æÈ¨ËùÓÐ ¹¤¿ØÍø Copyright@ Gkong.com, All Rights Reserved