Î÷ÃÅ×ÓCPUÄ£¿é317-2DP Î÷ÃÅ×ÓCPU317-2DP¿É±à³Ì¿ØÖÆÆ÷Ä£¿é Î÷ÃÅ×ÓCPU317-2DPÖÐÑë´¦ÀíÆ÷Ä£×é
ÏúÊÛ¶©»õºÅ£º
6ES7317-2AK14-0AB0
6ES7 317-2AJ10-0AB0
CPU 317-2 DP °²×°ÓУº
΢´¦ÀíÆ÷;
´¦ÀíÆ÷´¦ÀíÿÌõ¶þ½øÖÆÖ¸ÁîÖ´ÐÐʱ¼äԼΪ 25 ns£¬Ã¿Ìõ¸¡µãÊýÔËÐÐÖ¸ÁîԼΪ 160ns¡£CPU 317-2 DP ¾ßÓм«¸ßµÄ×ÖÖ¸Á˫×ÖÖ¸ÁîºÍ 32 붨µãÊýÖ¸Áî´¦ÀíËÙ¶È¡£
1 MB ¹¤×÷´æ´¢Æ÷£¨Ï൱ÓÚÔ¼ 340 K Ö¸Á£»
Óë³ÌÐò×é¼þÖ´ÐÐÏà¹ØµÄ´óÈÝÁ¿¹¤×÷´æ´¢Æ÷ΪÓû§³ÌÐòÌṩÁ˳ä·ÖµÄ¿Õ¼ä¡£×÷Ϊ³ÌÐò×°ÔØ´æ´¢Æ÷µÄ΢ÐÍ´æ´¢¿¨£¨×î´óΪ 8 MB£©Ò²ÔÊÐí½«¿ÉÒÔÏîÄ¿£¨°üÀ¨·ûºÅºÍ×¢ÊÍ£©±£´æÔÚ CPU ÖС£×°ÔØ´æ´¢Æ÷»¹¿ÉÓÃÓÚÊý¾Ý¹éµµºÍÅä·½¹ÜÀí¡£
Áé»îµÄÀ©Õ¹ÄÜÁ¦;
¶à´ï 32 ¸öÄ£¿é£¬£¨4ÅŽṹ£©
MPI/DP ×éºÏ½Ó¿Ú£»
µÚÒ»¸ö MPI/DP ¼¯³É½Ó¿Ú×î¶à¿ÉÒÔͬʱ½¨Á¢Óë S7-300/400 »ò±à³ÌÉ豸¡¢PC¡¢OP µÄ 32 ÌõÁ¬½Ó¡£ÔÚÕâЩÁ¬½ÓÖУ¬Ê¼ÖÕ·Ö±ðΪ PG ºÍ OP ¸÷±£ÁôÒ»¸öÁ¬½Ó¡£Í¨¹ýMPIºÍ“È«¾ÖÊý¾ÝͨѶ”¿ÉÒÔ¶Ô32¸öCPU½øÐмòµ¥×éÍø¡£
¸Ã½Ó¿Ú¿ÉÒÔ´Ó MPI ½Ó¿ÚÖØÐÂÉèÖÃΪ DP ½Ó¿Ú¡£DP ½Ó¿Ú¿ÉÓÃ×÷ DP Ö÷Õ¾»ò DP ´ÓÕ¾ÔËÐС£
PROFIBUS DP ½Ó¿Ú:
CPU 317-2 DP µÚ2¸öÄÚÖýӿÚÊÇÒ»¸ö´¿´âµÄ PROFIBUS DP ½Ó¿Ú£¬¿ÉÓÃ×÷ DP Ö÷Õ¾»ò DP ´ÓÕ¾¡£¿ÉÒÔ×齨һ¸ö¸ßËٵġ¢Ò×ÓÚ´¦ÀíµÄ·Ö²¼Ê½×Ô¶¯»¯½á¹¹¡£¶ÔÓû§À´Ëµ,·Ö²¼Ê½I/Oµ¥Ôª¿É×÷Ϊһ¸ö¼¯ÖÐʽµ¥ÔªÀ´´¦Àí(ÏàͬµÄ×é̬¡¢±àÖ·ºÍ±à³Ì)¡£ÔڸýӿÚÉÏ£¬PROFIBUS DP´ÓÕ¾¿ÉÔÚµÈʱģʽÏÂÔËÐУ®
È«ÃæÖ§³Ö PROFIBUS DP V1 ±ê×¼¡£Õ⽫Ôö¼Ó DP V1 ±ê×¼´ÓÕ¾ÔÚÕï¶ÏºÍ²ÎÊý¸³ÖµÄÜÁ¦µÄ·¶Î§¡£
ÏÞÖÆ:Á½¸ö½Ó¿Ú²»ÄÜͬʱ×÷Ϊ´ÓÕ¾À´ÔËÐС£
¿ÚÁî±£»¤;
Óû§³ÌÐòʹÓÃÃÜÂë±£»¤£¬¿É·ÀÖ¹·Ç·¨·ÃÎÊ¡£
¿é¼ÓÃÜ£»
º¯Êý (FC) ºÍ¹¦ÄÜ¿é (FB) ¿ÉÒÔͨ¹ý S7-Block Privacy£¬¼ÓÃÜ´æ´¢ÓÚ CPU ÒÔ±£»¤×¨Óм¼Êõ¡£
Õï¶Ï»º³å;
Õï¶Ï»º³åÇøÖпɴ洢×îºó 500 Ìõ´íÎóºÍÖжÏʼþ£¬ÆäÖÐµÄ 100 Ìõʼþ¿ÉÒÔ³¤ÆÚ´æ´¢¡£
Ãâά»¤µÄÊý¾Ýºó±¸;
ÔÚµçÔ´¹ÊÕÏʱ£¬CPU ½«×Ô¶¯±£´æËùÓÐÊý¾Ý£¨×î´ó 256 KB£©£¬´Ó¶øÊ¹Êý¾Ý¿ÉÒÔÔÚµçѹ»Ö¸´ºóÔÙ´ÎʹÓã¬ÇÒ²»»á·¢Éú¸Ä±ä¡£
¿É²ÎÊý»¯µÄÌØÐÔ
¿ÉÒÔʹÓà STEP 7 ¶Ô S7 µÄ×é̬¡¢ÊôÐÔÒÔ¼°CPUµÄÏìÓ¦½øÐвÎÊýÉèÖãº
¸ÅÊö£»
¶¨ÒåÃû³Æ¡¢ÉÏλÃû³ÆºÍλÖà ID
Æô¶¯£»
¶¨Òå CPU µÄÆô¶¯ÌØÐԺͼàÊÓʱ¼ä
ͬ²½Ñ»·Öжϣ»
ÉèÖà DP Ö÷վϵͳ¡¢¹ý³ÌÓ³Ïñ·ÖÇø±àºÅºÍÑÓʱʱ¼ä
Ñ»·/ʱÖÓ´æ´¢Æ÷£»
Ö¸¶¨×î´óÑ»·Ê±¼äºÍ¸ºÔØ£¬É趨ʱÖÓ´æ´¢Æ÷µØÖ·¡£ÆôÓÃÓÅÏÈ HMI ͨѶ
¼ÇÒäÐÔ£»
ÉèÖñ£³ÖÇø
ÈÕʱÖÓÖжϣ»
É趨ÆðʼÈÕÆÚ¡¢Æðʼʱ¼äºÍ¼ä¸ôÖÜÆÚ
ÖÜÆÚÖжϣ»
ÖÜÆÚÉ趨
ϵͳÕï¶Ï£»
È·¶¨Õï¶ÏÏûÏ¢µÄ´¦ÀíºÍ·¶Î§
ʱÖÓ£»
É趨ASÄÚ»òMPIÉϵÄͬ²½ÀàÐÍ
·À»¤µÈ¼¶£»
¶¨Òå³ÌÐòºÍÊý¾ÝµÄ·ÃÎÊȨÏÞ
ͨѶ£»
±£ÁôÁ¬½ÓÔ´
MPI/PROFIBUS-DP ½Ó¿Ú:
ÉèÖýӿÚÀàÐÍ¡£¶¨Òå½ÚµãµØÖ·¡£¶Ô²Ù×÷ģʽ½øÐвÎÊý»¯£¬²¢×é̬ʹÓà PROFIBUS DP ʱµÄ´«ÊäÇø¶Ôʱ¼äͬ²½½øÐвÎÊý»¯
PROFIBUS DP Ö÷Õ¾/´ÓÕ¾½Ó¿Ú;
Õë¶Ô·Ö²¼Ê½ I/O µÄÓû§¶¨Ò嵨ַ·ÖÅä¡£¶Ô²Ù×÷ģʽ½øÐвÎÊý»¯£¬²¢×é̬ʹÓà PROFIBUS DP ʱµÄ´«ÊäÇøÓò¡£¶Ôʱ¼äͬ²½½øÐвÎÊý»¯
S7-300
Ä£¿é»¯Î¢ÐÍPLCϵͳ£¬Âú×ãÖС¢Ð¡¹æÄ£µÄÐÔÄÜÒªÇó
¸÷ÖÖÐÔÄܵÄÄ£¿é¿ÉÒԷdz£ºÃµØÂú×ãºÍÊÊÓ¦×Ô¶¯»¯¿ØÖÆÈÎÎñ
¼òµ¥ÊµÓõķֲ¼Ê½½á¹¹ºÍ¶à½çÃæÍøÂçÄÜÁ¦£¬Ó¦ÓÃÊ®·ÖÁé»î
·½±ãÓû§ºÍ¼òÒ×µÄÎÞ·çÉÈÉè¼Æ
µ±¿ØÖÆÈÎÎñÔö¼Óʱ£¬¿É×ÔÓÉÀ©Õ¹
´óÁ¿µÄ¼¯³É¹¦ÄÜʹËü¹¦Äܷdz£Ç¿¾¢
S7-300F
¹ÊÕϰ²È«ÐÍ×Ô¶¯»¯ÏµÍ³£¬Âú×㹤³§ÈÕÒæÔö¼ÓµÄ°²È«ÐèÇó
»ùÓÚS7-300
¿ÉÁ¬½ÓÅäÓа²È«Ïà¹ØÄ£¿éµÄ¸½¼Ó ET 200S ºÍ ET 200M ·Ö²¼Ê½ I/O Õ¾
ͨ¹ý²ÉÓà PROFIsafe ÐйæµÄ PROFIBUS DP ½øÐа²È«Ïà¹ØÍ¨Ñ¶
´ËÍ⣬»¹ÓÐÓÃÓÚÓ밲ȫÎÞ¹ØÓ¦Óõıê׼ģ¿é
ʼ»¯²ÎÊýÓÃСд×Öĸ±íʾ£¬ÕâʹµÃËüÓëÔËÐвÎÊý¸üÈÝÒ×±»Çø·Ö¡£³õʼ»¯²ÎÊýÖ»ÓÐÔÚ OB100 Öе÷ÓÃʱ·½¿ÉÆÀ¹À£¬²¢±»´«Ë͵½ Modbus ¿éµÄ±³¾°Êý¾Ý¿éÖС£ÔÚÔËÐйý³ÌÖиıä³õʼ»¯²ÎÊýûÓÐÈκÎÓ°Ï죬ÒòΪֻÓÐÒÑ´æ´¢µÄÖµ±»´¦Àí¡£³õʼ»¯²ÎÊýÖ¸¶¨ÊµÏÖʲô¹¦ÄÜ£¬Èç¹ûÒª¸Ä±äÕâЩ²ÎÊý£¬±ÈÈçÔÚ²âÊÔģʽÏ£¬±³¾°Êý¾Ý¿é±ØÐëͨ¹ý CPU µÄÖØÆô£¨STOP>ÔËÐУ©²ÅÄܽøÐÐÖØÐ³õʼ»¯¡£ÔÚ³õʼ»¯²ÎÊýÖУ¬ÀýÈç Modbus ¼Ä´æÆ÷µÄÊý¾ÝÀàÐͱ»¶¨Ò壨data_type_1£©¡£´ËÍ⣬³õʼ»¯²ÎÊý»¹¶¨ÒåÁË CPU ÊÇ·þÎñÆ÷»òÊǿͻ§¶Ë£¨server_client£©¡£
ÔËÐвÎÊýÓôóд×Öĸ±íʾ£¬¿ÉÒÔÔÚÑ»·Ä£Ê½Ï¸ı䣬ÔËÐвÎÊý¶¨ÒåÁ˵±Ç°µÄ¹¤×÷¡£È»¶øµ±“CPU/ CP Êǿͻ§¶Ë”ģʽʱ£¬ÔËÐÐÖеÄÊäÈë²ÎÊýÊÇÎÞ·¨Ð޸ĵġ£Ö±µ½DONE_NDR »ò´íÎó±»ÖÃ룬¼´Ç°Ò»¸ö×÷ÒµÒѽáÊø£¬²ÅÄÜΪÏÂÒ»¸ö×÷Òµ×ö×¼±¸²¢¶ÔÏà¹Ø²ÎÊý×öÐ޸ġ£µ±“CPU/ CP ÊÇ·þÎñÆ÷”ģʽʱ£¬Ö»ÓÐ DONE_NDR ÖÃλʱ²ÅÄÜÆÀ¹ÀÊä³ö²ÎÊý¡£Êä³ö²ÎÊýÊǶ¯Ì¬ÏÔʾµÄ£¬Òò´ËÖ»ÔÚ1¸ö CPU Ñ»·ÖÜÆÚÄÚÓÐЧ¡£ÈκÎÐèÒª½øÒ»²½´¦Àí»òÔÚ±äÁ¿±íÏÔʾµÄÊä³ö²ÎÊý£¬¶¼±ØÐë´æ´¢ÔÚ²»Í¬µÄÄÚ´æÇøÓò¡£