SIMATIC DP£¬RS485ÖÐ¼ÌÆ÷µÄPROFIBUS/ MPI×ÜÏßϵͳµÄ×î´óµÄÁ¬½Ó¡£ 31¸ö½Úµã;×î´ó¡£ 12 Mbit / sµÄ£¬Ñ§Î»×¨ÒµTECTION IP20¸Ä½øµÄ¿ÉÓÃÐÔ
ÉϺ£Àø»Ô¿Æ¼¼×Ô¶¯»¯ÓÐÏÞ¹«Ë¾ÊÇרҵ´úÀí
µÂ¹ú£ºSIEMENSÎ÷ ÃÅ ×Ó£º PLC¼° Ä£¿é£º S7-200¡¢ S7-300¡¢ S7-400¡¢ÏµÁУ¬Í¨Ñ¶µçÀ¼°½ÓÍ·
±ä Ƶ Æ÷£º MM420¡¢ MM430¡¢ MM440¡¢ 6SE70¡¢ 6RA70ϵÁУ¬
´¥ Ãþ ÆÁ£º OP27¡¢ OP37¡¢ OP270¡¢ OP370µÈϵÁУ¬
Êý ¿Ø£º 6SN¡¢1FT¡¢6FC¡¢6FX£¬1FKµÈϵÁÐ
¹«Ë¾´úÀí²úÆ·£¬ÖÊÁ¿Õý×Ú£¬¼Û¸ñºÏÀí¡£Ïêϸ×ÉѯÇëä¯ÀÀ¹«Ë¾²úÆ·ÐÅÏ¢£¬Ï·½ÓÐÁªÏµ·½Ê½£¬»¶ÓÐÂÀϿͻ§À´µç×Éѯ¡£
µçÔ´µçѹ |
DC 24 V |
ÊÇ |
ÔÊÐí·¶Î§£¬ÏÂÏÞ (DC) |
20.4 V |
ÔÊÐí·¶Î§£¬ÉÏÏÞ (DC) |
28.8 V |
ÊäÈëµçÁ÷ |
ºÄÓõçÁ÷£¬×î´óÖµ |
100 mA; 100 mA£¬PG/OP²å×ùÉÏÎÞÓõçÆ÷£»130mA£¬PG/OP²å×ùÉÏ´æÔÚÓõçÆ÷£¨5V/90mA£©£»200mA£¬PG/OP²å×ùÉÏ´æÔÚÓõçÆ÷(24V/100mA) |
½Ó¿Ú |
×ÜÏßÏß· |
2 ¸ö½ô¹ÌÇøÓò |
PROFIBUS DP |
´«ÊäËÙÂÊ£¬×î´óÖµ |
12 Mbit/s; 9.6 kbit/s ÖÁ 12 Mbit/s |
·À»¤µÈ¼¶ºÍ·À»¤Àà±ð |
IP 20 |
ÊÇ |
»·¾³ÒªÇó |
ÔËÐÐÎÂ¶È |
×îСֵ |
0 °C |
×î´óÖµ |
60 °C |
´æ·Å/ÔËÊäÎÂ¶È |
×îСֵ |
-40 °C |
×î´óÖµ |
70 °C |
Ïà¶Ô¿ÕÆøÊª¶È |
×î´óÏà¶Ô¿ÕÆøÊª¶È |
95 %; 25 °C ʱ |
Á¬½Ó¼¼Êõ |
µçÔ´µçѹ |
½ÓÏߺР|
³ß´ç |
¿í¶È |
45 mm |
¸ß¶È |
128 mm |
Éî¶È |
67 mm |
ÖØÁ¿ |
ÖØÁ¿£¬Ô¼ |
350 g |
SIMATIC DP£¬RS485ÖÐ¼ÌÆ÷µÄPROFIBUS/ MPI×ÜÏßϵͳµÄ×î´óµÄÁ¬½Ó¡£ 31¸ö½Úµã;×î´ó¡£ 12 Mbit / sµÄ£¬Ñ§Î»×¨ÒµTECTION IP20¸Ä½øµÄ¿ÉÓÃÐÔ
ÉϺ£Àø»Ô¿Æ¼¼×Ô¶¯»¯ÓÐÏÞ¹«Ë¾ÊÇרҵ´úÀí
µÂ¹ú£ºSIEMENSÎ÷ ÃÅ ×Ó£º PLC¼° Ä£¿é£º S7-200¡¢ S7-300¡¢ S7-400¡¢ÏµÁУ¬Í¨Ñ¶µçÀ¼°½ÓÍ·
±ä Ƶ Æ÷£º MM420¡¢ MM430¡¢ MM440¡¢ 6SE70¡¢ 6RA70ϵÁУ¬
´¥ Ãþ ÆÁ£º OP27¡¢ OP37¡¢ OP270¡¢ OP370µÈϵÁУ¬
Êý ¿Ø£º 6SN¡¢1FT¡¢6FC¡¢6FX£¬1FKµÈϵÁÐ
- ¶Ô RS 485 ÖÐ¼ÌÆ÷µÄÃèÊö
- Á½¸ö RS 485 ÖÐ¼ÌÆ÷Ö®¼äµçÀµÄ×î´ó³¤¶È
- ¸÷ÖÖ²Ù×÷Ôª¼þºÍ¶Ë×ӵŦÄÜ
- °²×°ºÍ²ð³ý
- ÓйؽӵغͲ»½ÓµØÁ¬½ÓµÄÐÅÏ¢
- Á¬½ÓµçÔ´ºÍ×ÜÏß
- ¼¼Êõ¹æ·¶ºÍ·½¿òͼ
- ³ß´çͼ
-
6ES7972-0AA02-0XA0
ʲôÊÇ RS 485 ÖÐ¼ÌÆ÷£¿
RS 485 ÖÐ¼ÌÆ÷ÓÃÓÚ·Å´ó×ÜÏßÉϵÄÊý¾ÝÐźţ¨Õñ·ù¡¢±ßÑØÐ±ÂʺÍÐźŴø¿í£©²¢Á¬½Ó¸÷¸ö×ÜÏ߶Ρ£
RS 485 ÖÐ¼ÌÆ÷µÄÓ¦ÓÃ
RS 485 ÖÐ¼ÌÆ÷½«Á¬½ÓʹÓà RS 485 ¼¼ÊõµÄÁ½¸ö PROFIBUS »ò MPI ×ÜÏ߶Σ¬×î¶àÖ§³Ö 32 ¸ö½Úµã¡£ ÔÊÐíµÄ´«ÊäÂÊΪ 9.6 kbps µ½ 12 Mbps¡£
ÔÚÏÂÁÐÇé¿öÏ£¬¿ÉÄÜÐèÒª RS 485 ÖÐ¼ÌÆ÷£º
- ×ÜÏßÉÏÁ¬½ÓÁ˳¬¹ý 32 ¸ö½Úµã£¨°üÀ¨ÖÐ¼ÌÆ÷ÔÚÄÚ×î¶à 127 ¸ö½Úµã£©
- ×ÜÏ߶ΰ´×ÜÏß²»½ÓµØ½øÐÐÁ¬½Ó£¨×ÜÏß¶ÎµçÆø¸ôÀ룩
- ³¬³öÁË×ÜÏ߶εÄ×î´óµçÀ³¤¶È£¨Çë²Î¼ûÏÂ±í£©¡£
- ÔÚµ÷ÊÔ¹ý³ÌÖÐÐèÒª°ïÖú
- - ¶Ï¿ª×ÜÏ߶μäµÄÁ¬½Ó
- - ÏÔʾ×ÜÏ߻
- - ÔÚ´íÎó²åÈëÁËÖն˵ç×èʱ¶Ï¿ª×ÜÏß¶Î
- ÖØÐÂÉú³ÉÕñ·ùºÍʱ¼äÐźÅ
-
Áбí: ×ÜÏ߶εçÀµÄ×î´ó³¤¶È
´«ÊäÂÊ
|
×ÜÏ߶εçÀµÄ×î´ó³¤¶È£¨Ã×£©
|
9.6 µ½ 187.5 kbps
|
1000
|
500 kbps
|
400
|
1.5 Mbps
|
200
|
3 µ½ 12 Mbps
|
100
|
¹æÔò
Èç¹û½¨Á¢´øÓÐ RS 485 ÖÐ¼ÌÆ÷µÄ PROFIBUS ÍøÂ磺
- ±ØÐëÔÚ STEP 7 ÖÐ×é̬ RS 485 ÖÐ¼ÌÆ÷µÄ´®ÁªÊýÁ¿¡£
- ×î¶à¿É´®Áª 9 ¸ö RS 485 ÖÐ¼ÌÆ÷¡£
- ʹÓà RS 485 ÖÐ¼ÌÆ÷µÄÁ½¸ö½Úµã¼äµçÀµÄ×î´ó³¤¶È£¬²»µÃ³¬¹ýϱíÖÐÁгöµÄÖµ¡£
-
Áбí: Á½¸ö RS 485 ÖÐ¼ÌÆ÷Ö®¼äµçÀµÄ×î´ó³¤¶È
´«ÊäÂÊ
|
ʹÓà RS 485 ÖÐ¼ÌÆ÷µÄÁ½¸ö½Úµã¼äµçÀµÄ×î´ó³¤¶È£¨Ã×£©
|
9.6 µ½ 187.5 kbps
|
10000
|
500 kbps
|
4000
|
1.5 Mbps
|
2000
|
3 µ½ 12 Mbps
|
1000
|