SIMATIC HMI, TP1900 ¾«ÖÇÃæ°å18.5 ´ç£¬1600 ÍòÉ« LED ±³¹â£¬16:9 ¿íÆÁÏÔʾ£¬´¥ÃþÆÁ£¬24 MB Óû§ÄÚ´æ
ÉϺ£Àø»Ô£¨Î÷ÃÅ×ÓÉϺ£×ܾÏú£©
Î÷ÃÅ×ÓÇý¶¯Óë×Ô¶¯»¯×î¼ÑºÏ×÷»ï°é
Ö÷ÓªÎ÷ÃÅ×ӵ¹úÔ×°½ø¿Ú£º
Î÷ÃÅ×Ó PLC|S7-200CN|S7-200|S7-300|S7-400|
S7-1200|ET200µÈϵÁÐ
Î÷ÃÅ×Ó T400|TDC¸ß¶Ë¿ØÖÆÆ÷|
Î÷ÃÅ×Ó PCS7¹ý³Ì¿ØÖÆÏµÍ³£¬
Î÷ÃÅ×Ó 808D|810D|840D|828DÊý¿ØÏµÍ³¼°±¸¼þ
Î÷ÃÅ×Ó MM4|G110|G120|V10±ê×¼±äƵÆ÷£¬
Î÷ÃÅ×Ó S120|611ϵÁÐËÅ·þϵͳ
Î÷ÃÅ×Ó profibus-DPÏÖ³¡×ÜÏßϵͳ
Î÷ÃÅ×Ó Ö±Á÷µçÔ´SITOP ϵÁÐ 24V DC 1.3A¡¢2.5A¡¢3A¡¢5A¡¢10A¡¢20A¡¢40A
Î÷ÃÅ×Ó È«Êý×ÖÖ±Á÷µ÷ËÙ×°ÖÃ6RA70|6RA80|
Î÷ÃÅ×Ó ´¥ÃþÆÁTD200 TD400C TP177,MP277 MP377 TP700 TP900 TP1200 TP1500
KTP178µÈ
Î÷ÃÅ×Ó µç»ú£¬Î÷ÃÅ×Ó¹ý³ÌÒDZí
·²ÎÒ¹«Ë¾³öÊÛµÄÎ÷ÃÅ×Ó²úÆ·¾ùÏíÊÜÎ÷ÃÅ×Ó¹Ù·½Öʱ£Ò»Ä꣬һÄêÄÚÓÐÈκÎÖÊÁ¿ÎÊÌâ
Ãâ·ÑÌṩ»»Ð»òάÐÞ·þÎñ,²»ÊÕÈ¡ÈκηÑÓã¡
6AV2124-0GC01-0AX0 Î÷ÃÅ×ÓTP700¾«ÖÇϵÁд¥ÃþÆÁ7´ç
6AV2124-0JC01-0AX0 Î÷ÃÅ×ÓTP900¾«ÖÇϵÁд¥ÃþÆÁ9´ç
6AV2124-0MC01-0AX0 Î÷ÃÅ×ÓTP1200¾«ÖÇϵÁд¥ÃþÆÁ12´ç
6AV2124-0QC02-0AX0 Î÷ÃÅ×ÓTP1500¾«ÖÇϵÁд¥ÃþÆÁ15´ç
6AV2124-0UC02-0AX0 Î÷ÃÅ×ÓTP1900¾«ÖÇϵÁд¥ÃþÆÁ19´ç
- ¹ý³Ì²ÎÊýµÄÏÔʾºÍÐÞ¸Ä
- ¹¦ÄܼüÓÃÓÚÖ±½Ó´¥·¢°´¼ü²Ù×÷É豸£¨´øÓÐ KTP400£©ÖеŦÄܺͲÙ×÷¡£ÔÚ¹¦ÄܼüÉÏ×î¶à¿ÉÒÔͬʱÅäÖà 16 ÖÖ¹¦ÄÜ¡£¹¦Äܼü¿ÉÒÔÓÃ×ö PROFIBUS DPÊäÈëÍâÉèÉ豸»òÖ±½ÓÓÃ×÷ PROFINET IO¡£
- ¹ý³ÌÏÔʾ£º
- ʸÁ¿Í¼ÐΣ¨¸÷ÖÖÏßÌõÓëÆ½Ãæ¶ÔÏó£©
- ¶ÔÏóµÄ¶¯Ì¬¶¨Î»ÒÔ¼°¶ÔÏóµÄ¶¯Ì¬ÏÔʾ/Òþ²Ø
- ȫͼÐÎÏÔʾ¡¢»æÍ¼ºÍÌõÐÎͼÏÔʾ
- ÿ¸öÇ÷ÊÆÇøÓòÏÔʾ×î¶à 8 ¸öÇ÷ÊÆ£»´ø¹ö¶¯ºÍËõ·Å¹¦ÄܵÄÇ÷ÊÆÇúÏßͼ£¬¿É·ÃÎÊÀúÊ·¼Ç¼²¢Áé»îÑ¡ÔñÏÔʾʱ¼ä¶Î£»¿Éͨ¹ýÔĶÁ±ê³ßÀ´È·¶¨µ±Ç°Öµ²¢ÔÚÒ»¸ö±íÖÐÏÔʾ
- ×ÛºÏͼÐο⣨SIMATIC HMI ·ûºÅ¿â£©
- ͼ±ê£º»¬¿é¡¢Á¿±í¡¢Ê±ÖÓ
- ͨ¹ý±¨¾¯Ê±ÖÓ½øÐÐÑ»·¹¦ÄÜ´¦Àí
- ÓÃÓÚ±äÁ¿µÄ¶àÖÖ¹¦ÄÜ
- ·¢ÐÅϵͳ
- ÀëÉ¢±¨¾¯ºÍÄ£ÄâÁ¿±¨¾¯£¨ÏÞÖµ±¨¾¯£©
- ¾ßÓпÉ×ÔÓɶ¨ÒåµÄÏûÏ¢¼¶±ð£¨Èç״̬/¹ÊÕÏÏûÏ¢£©£¬ÓÃÓÚ¶¨ÒåÈ·ÈÏÏìÓ¦ºÍÏÔʾÏûϢʼþ
- ÀûÓÃÏûÏ¢ÀúÊ·Êý¾Ý½øÐÐ״̬ºÍ¹ÊÕÏÏûÏ¢¹ÜÀí
- Óë×é̬µÄÏûÏ¢ÆÁÄ»¡¢ÏûÏ¢´°¿ÚºÍÏûÏ¢ÐÐ
- ¹éµµÏûÏ¢ºÍ¹ý³ÌÖµ£¨ÔÚ CF/SD/¶àýÌå´æ´¢¿¨/USB ÉÁÅÌÉÏ£¬»òͨ¹ýÒÔÌ«ÍøÔÚÍøÂçÇý¶¯Æ÷ÉϹ鵵£©
- ¸÷Öֹ鵵ÀàÐÍ£ºÑ»·¹éµµºÍÐòÁй鵵
- °´ÕÕ±ê×¼µÄ Windows ¸ñʽ £¨CSV£© ¶Ô¹éµµÊý¾Ý½øÐзÖÀà
- ÀûÓÃÇ÷ÊÆÇúÏßÔÚÏ߯À¹À¹ý³ÌÖµ¹éµµ
- ¿ÉÒÔʹÓñê×¼¹¤¾ß£¨MS Excel¡¢MS Access£©½øÐÐÍⲿ·ÖÎö
- ±¨¾¯¼Ç¼ºÍÖµ°à¼Ç¼
- ´òÓ¡¹¦ÄÜ£¨²Î¼û“ÍÆ¼ö´òÓ¡»ú”£©
- ÓïÑÔ¸ü¸Ä
- 32 ÖÖÔÚÏßÓïÑÔ£¬32 ÖÖ×é̬ÓïÑÔ£¬°üÀ¨ÑÇÖÞºÍÎ÷Àï¶û×Öĸ×Ö·û¼¯¡£
- Åä·½¹ÜÀí
- ´øÓи½¼ÓÊý¾Ý´æ´¢Æ÷£¨ÔÚ SD/¶àýÌå´æ´¢¿¨/USB ÉÁÅ̵ÈÉÏÃæ£©
- ÔÚÃæ°åÉϽøÐÐÔÚÏß / ÀëÏß´¦Àí
- ÒÔ±ê×¼µÄ Windows ¸ñʽ±£´æÅä·½Êý¾Ý (CSV)
- ¿ÉÀûÓñê×¼¹¤¾ß£¨MS Excel¡¢MS Access£©½øÐÐÍⲿ´¦Àí
- ±à³ÌÆ÷¹¦ÄÜ STATUS/FORCE VAR Óë SIMATIC S7 Ïà½áºÏ
- Õï¶ÏÏÔʾÓë SIMATIC S7 Ïà½áºÏ¿ÉÖ§³Ö¿ìËÙÎÊÌâÅŲé
- PLC µÄÆÁĻѡÔñÔÊÐí´Ó PLC ½øÐвÙ×÷Ô±¿ØÖÆ
- ͨ¹ý MS Internet Explorer ÏÔʾ HTML Îĵµ
- VB ½Å±¾£¬Í¨¹ýÖ´ÐÐһЩй¦ÄÜ£¬ÆäÖаüÀ¨Óë±äÁ¿½Ó¿Ú£¨±È½ÏÔËË㣬»·Í¨µÈ£©£¬´Ó¶ø¾ß±¸Á¼ºÃµÄÁé»îÐÔ
- ¹ý³Ì»Ãæ¡¢±¨¾¯ºÍ±äÁ¿µÄ°ïÖúÎı¾
- ËãÊõº¯Êý
- ÏÞÖµ¼àÊÓÓÃÓÚÊäÈëºÍÊä³öµÄ¿É¿¿¹ý³Ì¿ØÖÆ