Ê×Ò³ - ÐÂÎÅ - ÕÐÆ¸ - ÏÂÔØ - ²úÆ· - ³§ÉÌ - ·½°¸ - ÎÄÕª - Çó¹º - Õ¹ÀÀ
Ãâ·Ñ×¢²á µÇ¼ | ¹ã¸æ·þÎñ | ¿Í·þÖÐÐÄ
Öлª¹¤¿ØÍø ¡ú ¹¤¿Ø²úÆ· ¡ú Fluke 717 ϵÁÐѹÁ¦Ð£×¼Æ÷
²úÆ·Ãû³Æ£º Fluke 717 ϵÁÐѹÁ¦Ð£×¼Æ÷
ÐÍ ºÅ£º Fluke 717
¼Û ¸ñ£º 0.00
Æ· ÅÆ£º
 
Êղش˲úÆ·     ²é¿´ÊÕ²Ø

 

²âÁ¿×¼È·¶È
ѹÁ¦
717 ϵÁÐ  
²âÁ¿Ñ¹Á¦  £¨ÄÚÖô«¸ÐÆ÷£©
׼ȷ¶È:   0.05% Âú¶È
¹¦ÄÜ:  ¹éÁã¡¢×îСֵ¡¢×î´óÖµ¡¢±£³Ö¡¢×èÄá
   ×¢ÒâÆøÌå/ÒºÌ壨·Ç¸¯Ê´ÐÔ£©
   
Fluke 717 1G  
Á¿³Ì:  -1 ÖÁ 1 PSI£¬£¨-68.9 mbar ÖÁ 68.9 mbar£¬-83 ÖÁ 6.89 kPa£©
·Ö±æÂÊ:  0.0001 PSI£¬0.001 mbar£¬0.0001 kPa
¹ýѹ:  5 X Âú¶È
   
Fluke 717 30G  
Á¿³Ì:  -12 ÖÁ 30 PSI£¬£¨-850 mbar ÖÁ 2 bar£¬-83 ÖÁ 206.84 kPa£©
·Ö±æÂÊ:  0.001 PSI£¬0.1 mbar£¬0.01 kPa
¹ýѹ:  2 X Âú¶È
   
Fluke 717 100G  
Á¿³Ì:  -12 ÖÁ 100 PSI£¬£¨-850 mbar ÖÁ 7 bar£¬-83 ÖÁ 689.48 kPa£©
·Ö±æÂÊ:  0.01 PSI£¬0.1 mbar£¬0.01 kPa
¹ýѹ:  2 X Âú¶È
   
Fluke 717 300G  
Á¿³Ì:  -12 ÖÁ 300 PSI£¬£¨-850 mbar ÖÁ 20 bar£¬-83 ÖÁ 2068.42 kPa£©
·Ö±æÂÊ:  0.01 PSI£¬1 mbar£¬0.1 kPa
¹ýѹ:  375 PSI£¬25 bar
   
Fluke 717 500G  
Á¿³Ì:  0 ÖÁ 500 PSI£¬£¨0 mbar ÖÁ 34.7 bar£¬0 ÖÁ 3447.38 kPa£©
·Ö±æÂÊ:  0.01 PSI£¬1 mbar£¬0.1 kPa
¹ýѹ:  2 X Âú¶È
   
Fluke 717 1000G  
Á¿³Ì:  0 ÖÁ 1000 PSI£¬£¨0 mbar ÖÁ 69 bar£¬0 ÖÁ 6894.76 kPa£©
·Ö±æÂÊ:  0.1 PSI£¬1 mbar£¬0.1 kPa
¹ýѹ:  2 X Âú¶È
   
Fluke 717 1500G  
Á¿³Ì:  0 ÖÁ 1500 PSI£¬£¨0 bar ÖÁ 103.4 bar£¬0 ÖÁ 10342 kPa£©
·Ö±æÂÊ:  0.1 PSI£¬0.01 mbar£¬1 kPa
¹ýѹ:  2 X Âú¶È
   
Fluke 717 3000G  
Á¿³Ì:  0 ÖÁ 3000 PSI£¬£¨0 bar ÖÁ 207 bar£¬0 ÖÁ 20684.27 kPa£©
·Ö±æÂÊ:  0.1 PSI£¬0.01 mbar£¬1 kPa
¹ýѹ:  2 X Âú¶È
   
Fluke 717 5000G  
Á¿³Ì:  0 ÖÁ 5000 PSI£¬£¨0 bar ÖÁ 345 bar£¬0 ÖÁ 34474 kPa£©
·Ö±æÂÊ:  0.1 PSI£¬0.01 mbar£¬1 kPa
¹ýѹ:  2 X Âú¶È
   
²ÉÓÃѹÁ¦Ä£¿éµÄ Fluke 717 ϵÁÐ  
²âÁ¿Ñ¹Á¦  £¨Í¨¹ýѹÁ¦Ä£¿éÁ¬½ÓÆ÷£¬Ê¹ÓÿÉѡѹÁ¦Ä£¿é£©
Á¿³Ì:  29 ¿îѹÁ¦Ä£¿é£¬0-1 inH20 ÖÁ 10,000 PSI£¬2.5 mbar ÖÁ 700 bar¡£ ¹ýѹ±£»¤·ûºÏѹÁ¦Ä£¿é¼¼ÊõÖ¸±ê
·Ö±æÂÊ:  ·ûºÏѹÁ¦Ä£¿é¼¼ÊõÖ¸±ê
׼ȷ¶È:  ·ûºÏѹÁ¦Ä£¿é¼¼ÊõÖ¸±ê
¹¦ÄÜ:  ¹éÁã¡¢×îСֵ¡¢×î´óÖµ¡¢±£³Ö¡¢×èÄá
µçÁ÷
Á¿³Ì:  0 ÖÁ 24 mA£¨-25% ÖÁ 125%£©
·Ö±æÂÊ:  0.001 mA
׼ȷ¶È:  0.015% + 2 λÊý

 

¼¼ÊõÖ¸±ê
»ØÂ·µçÔ´
Á¿³Ì:  24 V dc
׼ȷ¶È:  +/- 10%
   ×¢: Çý¶¯£»µç³Ø >6.8V ʱΪ 20 mA£¬1000 ohms£»µç³Ø 5.8 ÖÁ 6.8 V ʱΪ 700 W
ÏÔʾ
   ¸ß¶ÈÇåÎúµÄ 5 λÊý×ÖÒºÁ¿ÏÔʾÆÁ

 

»·¾³¼¼ÊõÖ¸±ê
¹¤×÷ζÈ
   -10 ºC ÖÁ 55 ºC
´¢´æÎ¶È
   -40 ºC ÖÁ 60 ºC
ʪ¶È£¨ÎÞÀäÄý£©
   95%£¨10 ºC ÖÁ 30 ºC£©
   75%£¨30 ºC ÖÁ 40 ºC£©
   45%£¨40 ºC ÖÁ 50 ºC£©
   35%£¨50 ºC ÖÁ 55 ºC£©
ÔËÐк£°Î¸ß¶È
   ×î¸ß 3,000 m

 

°²È«¼¼ÊõÖ¸±ê
°²È«
   CSA C22.2 No. 1010.1:1992

 

»úеºÍͨÓü¼ÊõÖ¸±ê
³ß´ç
   201 mm£¨³¤£©x 98 mm£¨¿í£©x 52 mm
ÖØÁ¿
   ÖØÔ¼ 600 g£¨°üÀ¨»¤Ì×£©
±£ÐÞÆÚ
   3 Äê
Õ𶯺ÍÕñ¶¯
   Ëæ»ú£¬2 g£¬5-500 Hz
   1 Ã×Âä²î²âÊÔ
µç³ØÀàÐÍ
   1 ½Ú 9V ANSI/NEDA 1604A »ò IEC 6LR619V ¼îÐÔµç³Ø
 


¹«Ë¾¼ò½é
²úƷĿ¼
¹©Ó¦ÐÅÏ¢

¹«Ë¾Ãû³Æ£º ÉϺ£È«¾°Í¨ÓÃÉ豸ÓÐÏÞ¹«Ë¾
µç »°£º 021 33030187 / ¼ÖÒøÓ¢
ÊÖ»ú£º 13564482318
µØ Ö·£º ÉϺ£Êг¤ÄþÇø×ñÒåÄÏ·8ºÅ½õÃ÷´óÏÃ4D
ÓÊ ±à£º 200336
Ö÷ Ò³£º http://www.buy1718.com

¸Ã³§ÉÌÏà¹Ø²úÆ·£º
  • Fluke VT04 ¿ÉÊÓºìÍâ²âÎÂÒÇ
  •  
  • VT02 ¿ÉÊÓºìÍâ²âÎÂÒÇ
  •  
  • Fluke 561 ºìÍâÏßÓë½Ó´¥Ê½²âÎÂÒÇ
  •  
  • Fluke 568/566 ºìÍâ½Ó´¥Ê½µãÎÂÒÇ
  •  
  • Fluke NORMA 4000/5000 ¸ß¾«¶È¹¦ÂÊ·ÖÎöÒÇ
  •  
  • Fluke 1735 ÈýÏàµçÄܼǼÒÇ
  •  
  • Fluke 1750 ÈýÏàµçÄܼǼÒÇ
  •  
  • Fluke 1740 ϵÁÐÈýÏàµçÄÜÖÊÁ¿¼Ç¼ÒÇ
  •  
  • Fluke 1760 ÈýÏàµçÄÜÖÊÁ¿¼Ç¼ÒÇ
  •  
  • Fluke 1730 ÈýÏàµçÄÜÁ¿¼Ç¼ÒÇ
  •  
    ¸ü¶à²úÆ·...
      ¹ØÓÚÎÒÃÇ | ÁªÏµÎÒÃÇ | ¹ã¸æ·þÎñ | ±¾Õ¾¶¯Ì¬ | ÓÑÇéÁ´½Ó | ·¨ÂÉÉùÃ÷ | ·Ç·¨ºÍ²»Á¼ÐÅÏ¢¾Ù±¨  
    ¹¤¿ØÍø¿Í·þÈÈÏߣº0755-86369299
    °æÈ¨ËùÓÐ ¹¤¿ØÍø Copyright@ Gkong.com, All Rights Reserved