Ê×Ò³ - ÐÂÎÅ - ÕÐƸ - ÏÂÔØ - ²úÆ· - ³§ÉÌ - ·½°¸ - ÎÄÕª - Çó¹º - Õ¹ÀÀ
Ãâ·Ñ×¢²á µÇ¼ | ¹ã¸æ·þÎñ | ¿Í·þÖÐÐÄ
Öлª¹¤¿ØÍø ¡ú ¹¤¿Ø²úÆ· ¡ú EN 50264 ±ê×¼±ÚµçÁ¦¼°¿ØÖƵçÀÂ
²úÆ·Ãû³Æ£º EN 50264 ±ê×¼±ÚµçÁ¦¼°¿ØÖƵçÀÂ
ÐÍ ºÅ£º FRL-SW-1SU
¼Û ¸ñ£º
Æ· ÅÆ£º 11053
 
Êղش˲úÆ·     ²é¿´ÊÕ²Ø

Caledonian µçÀÂÓÐÏÞ¹«Ë¾ÓµÓÐÒ»Ì×ÍêÕûµÄÉú²ú¸÷ÖÖÍ­Àº͸÷ÖÖ¹âÏ˵ÄÏȽøÉ豸£¬¿ÉÒÔÉú²ú³öÊýÒÔ°Ù¼ÆÖÖÀàµÄ²¼Ïßϵͳ²úÆ·¡£ÎÒÃǵĸ÷ÖÖÍ­Àº͸÷ÖÖ¹âÏ˵IJúÆ·ÐÔÄÜ׿Խ£¬ÓÅÖʵķþÎñÖÊÁ¿£¬²»½öΪ¹ã´óÓû§ÌṩÁ˸ÃÁìÓòÄڵĸ߶˲úÆ·£¬»¹½«¸÷ÖÖÏßÀµÄÓ¦Ó÷¢»Óµ½Á˼«Ö¡£
ÔÚ¸÷ÖÖ¹ú¼Ê±ê×¼·½Ã棬 Caledonian µçÀ²úÆ·¸ù¾Ý¿Í»§ÐèÒª£¬¿É·ûºÏÓ¢¹ú±ê×¼BS£¨BS2863/4006/5308/5467/5468/6004/6007/6141/6300/6346/6360/6387/ 6425/6500/6724/6746/6853/6899/7211/µÈ £©¡¢Å·ÖÞ±ê×¼EN£¨EN50173/50264/50265/50266/50288/50306/50382/ 10257-1:1998/ 10257-2:1998/ 186003:1994/ 186160:1997/ 1862:1998µÈ£©¡¢·¨¹ú±ê×¼NF£¨NF CR1 C1/F 16-101/F 63-826/F 63-808/F 63-827/ C32-321/ C32-322/ C32-070µÈ£©¡¢µÂ¹ú±ê×¼DIN/VDE£¨DIN5510/51900|/VDE0281/0282/0295/0245/0812/0814/0276µÈ£©¡¢Òâ´óÀû±ê×¼UNI(H03VV-F/H03VVH2-F/H05VV-F/H05VVH2-F/H05RN-F/H05RNH2-F/H05RR-F/H07RN8-F/H03RT-H/A07RN-F/FR2OH2R/FG7OHH2R)ÃÀ¹ú±ê×¼RS/ANSI£¨RS 485/422/232/423/568|ANSI/UL83/1063/44/1581£©¡¢ÆÏÌÑÑÀ±ê×¼£¨NP£©¡¢Î÷°àÑÀ±ê×¼UNE£¨UNE211002/21123/211025/21150£©¡¢¹ú¼Êµç¹¤Î¯Ô±»á±ê×¼IEC£¨IEC11801/60502-1/60502-2/60332-1/60332-3/60331/60754-1/61034/61156/60228µÈ£©¡¢¹ú¼Ê±ê×¼ISO£¨ISO 9001/14000/4589-3£©µÈµÈ¡£
Õ⼸ʮÄêÀ´£¬ Caledonian µçÀÂÓÐÏÞ¹«Ë¾Ò»Ö±¶¼ÔÚÎȶ¨µØÔö¼Ó×ÔÉíµÄ»õÎï´¢±¸²¢²»¶ÏµØÍØÕ¹ÓëÈ«ÇòµÄ¿Í»§ºÍºÏ×÷»ï°éÖ®¼äµÄóÒ×¹Øϵ£¬²¢ÇÒÒѾ­ÔÚÅ·ÖÞºÍÑÇÖÞ¿ª±ÙÁËÊг¡·Ý¶î¡£ 
Caledonian»¹ÔÚÑÇÖÞÉèÁ¢ÁË°ìÊ´¦£¬°üÀ¨¶«ÄÏÑǵÄмÓÆ£¬ÖйúµÄÉϺ£ºÍÏã¸Û£¬ÈÕ±¾µÄ¶«¾©µÈµØ¡£²úÆ·µÄ·ÖÅäÓɽüÆÚÔÚÖйúºÍмÓÆÂÉèÁ¢µÄ°ìÊ´¦Ìṩ֧³Ö¡£
¶ÔÓÚº£ÍâÏîÄ¿CaledonianÓÈÆäÓиüºÃµÄÓÅÊÆ£¬¶ÔÓÚº£ÍâÏîÄ¿¿Í»§ÎÒÃÇ¿ÉÌṩ£ºÕë¶Ô¸ÃÏîÄ¿µÄרҵ²ÊÒ³£»º£ÍâÏîÄ¿±¨Éó×ÊÁÏ£»²úÆ·ÑùÆ·£»¿ÉÌṩµÚÈý·½¼ì²â±¨¸æ£»¿É²ÉÓú£ÔË¡¢¿ÕÔ˵ȶàÖÖ·½Ê½ÔËÊ䣻¿ÉÓ뺣Íâ¼àÀí¡¢ÒµÖ÷½øÐÐÃæ¶ÔÃ湵ͨºÍ²úÆ·ÑÝʾ¡£
CaledonianÒѾ­¸úÐí¶à¹ú¼ÒÏîÄ¿³É¹¦ºÏ×÷£¬°üÀ¨»ú³¡ÅܵÀϵͳ¡¢»ú³¡ÐÐÀîϵͳ¡¢µç³§¿ØÖÆϵͳ¡¢¸ßËÙ¹«Â·¿ØÖÆϵͳ¡¢¸ßËÙ¹«Â·ÊÕ·Ñϵͳ¡¢¸ßËÙÌú·»ú³µ¡¢µØÌúµçÀÂϵͳ¡¢ÈûÀ­ÃÅ¡¢ÆÁ±ÎÃÅ¡¢¿Õµ÷¡¢PIS¡¢CCTVϵͳµÈ£¬ÔÚ¸÷¹úÁôϸßÆ·ÖʵÄÏîÄ¿ÖÊÁ¿ºÍÆ·ÅÆ¿Ú±®¡£
CaledonianÆÚ´ýÓëÄúµÄÕæ³ÏºÏ×÷¡£

FIREROL FRL-SW-1SU/FRL-SW-3SU

 


A. µ¼Ìå                                              B. ¾øÔµ

 

Ó¦ÓÃ
ÔÚÌú·ÔËÊä»ú³µµÄÄÚ²¿»òÍⲿ°²×°Ê±ÓÃ×÷µçÁ¦ºÍ¿ØÖƵçÀ£¬ÔÚÕâÖÖ»·¾³Ï°áÔ˺Ͱ²×°³É±¾ÊÇÐèÒª¿¼ÂǵĺÜÖØÒªÒòËØ¡£
ÓÃÓÚ¿ØÖÆ£¬¸¨ÖúºÍÖ÷µç·½ÓÏßÈçÓÐÏßµçÊÓµõ´ø£¬¿ª¹ØºÍ¿ØÖÆÃæ°å£¬¼Ýʻ̨µÈ¡£

 

µçÀ½ṹ
µ¼Ìå
·ûºÏHD383 (IEC 60228) class 5 ±ê×¼µÄÈáÈí¶ÆÎýÍË»ðÍ­Ë¿
¾øÔµ
·ûºÏEN 50264-1 ±ê×¼ (EI 101 ÖÁ EI 104) µÄµÍÑÌÎÞ±µ¯ÐÔ»¯ºÏÎï

 

µçÆø¼°»úеÐÔÄÜ

µçѹ

0.6/1 kV »ò 1.8/3 kV

µ¼Ìå×î¸ß¶î¶¨Î¶È

90¡æ ( ¹Ì¶¨°²×°)

ÔÊÐí×îµÍ»·¾³Î¶È

-25¡æ /-40¡æ ( ¹Ì¶¨°²×°)

×îСÍäÇú°ë¾¶

3 ±¶×î´óÍ⾶ (D<12mm)

4 ±¶×î´óÍ⾶ (D>12mm)

 

»¯Ñ§¼°»·¾³ÌØÐÔ

EN 60684-2 ÎÞ·ú
EN 50305; EN 60811-2-1 ÄÍÓͼ°·ÀȼÁÏ
EN 50305 ·À³ôÑõ

 

³µÔØϵͳӦÓõķÀ»ðÐÔÄÜ

EN 50306-2 ΣÏյȼ¶ HL1, HL2/HL3, HL4
DIN 5510-2   °²È«µÈ¼¶ 1/2/3/4
BS 6853  ÊÒÄÚÓ¦ÓÃ 1a, 1b, II; ÊÒÍâÓ¦ÓÃ 1a, 1b, II
NF F 16-101 FO

 

»ù±¾·À»ðÐÔÄÜ

EN 50265-2-1; IEC 60332-1; BS 4066-1 µ¥¸ù¾øÔµµçÏß( µçÀÂ) ´¹Ö±»ðÑæ´«²¥²âÊÔ
EN 50266-2-4 + EN 50305; IEC 60332-3C ³ÉÊøµçÏß( µçÀÂ) »ðÑæ´«²¥²âÊÔ
VDE 0472 Teil 804; BS 4066-3; NFC 32070  
EN 50268-2; IEC 61034-2; VDE 0472 Teil 816 ÑÌÃܶȲâÊÔ
EN 50267-2-1; IEC 60754-1; VDE 0472 Teil 815 ÎÞ±²âÊÔ
EN 50267-2-2/3; IEC 60754-2; VDE 0472 Teil 813 ÆøÌ帯ʴÐÔ²âÊÔ ( Ëá¶È & ´«µ¼ÐÔ)
EN 50305; NFX 70-100; NFF 63808; TM1-04; BS6853 ¶¾ÐÔÖ¸Êý²âÊÔ
NFF 16101; NFF 63808; BS6853 ÑÌÖ¸Êý²âÊÔ

FRL-SW-1SU 0.6/1 kV

µ¼Ìå½ØÃæ»ý

µ¼ÌåÖ±¾¶ (a)

×îСƽ¾ù¾øÔµºñ¶È

ÏßÀÂÍ⾶

ÖØÁ¿

×î´óµ¼Ìå×迹

×îС¾øÔµ×迹

×îС

×î´ó

20°C

20°C

90°C

mm2

mm

mm

mm

mm

kg/km

Ω/km

MΩ·km

MΩ·km

1.0

1.25

0.8

2.8

3.2

18

20

65

0.65

1.5

1.5

0.8

3.0

3.5

20

13.7

55

0.55

2.5

1.95

0.8

3.4

3.9

30

8.21

50

0.5

4.0

2.5

0.8

3.9

4.6

50

5.09

40

0.4

6.0

3.0

0.9

4.6

5.4

70

3.39

35

0.35

10

3.9

1.1

5.8

6.8

130

1.95

30

0.3

16

5.0

1.1

7.2

8.5

170

1.24

30

0.3

25

6.4

1.3

8.6

10

260

0.795

30

0.3

35

7.7

1.3

10.2

11.5

350

0.565

25

0.25

50

9.2

1.5

11.6

13.5

500

0.393

25

0.25

70

11.0

1.5

13.3

15.5

690

0.277

20

0.2

95

12.5

1.6

14.9

17.4

910

0.210

20

0.2

120

14.2

1.6

16.5

19.3

1120

0.164

20

0.2

150

15.8

1.9

18.5

21.7

1430

0.132

15

0.15

185

17.5

1.9

20.1

23.6

1720

0.108

15

0.15

240

20.1

2.1

22.9

26.8

2290

0.0817

15

0.15

300

22.5

2.2

25.4

29.7

2810

0.0654

10

0.1

400

25.8

2.3

28.7

33.6

2690

0.0495

10

0.1

(a) = ½ö¹©²Î¿¼

 

FRL-SW-3SU 1.8/3 kV

µ¼Ìå½ØÃæ»ý

µ¼ÌåÖ±¾¶ (a)

×îСƽ¾ù
¾øÔµºñ¶È

ÏßÀÂÍ⾶

ÖØÁ¿

×î´óµ¼Ìå×迹

×îС¾øÔµ×迹

×îС

×î´ó

20°C

20°C

90°C

mm2

mm

mm

mm

mm

kg/km

Ω/km

MΩ·km

MΩ·km

1.5

1.5

2.5

6.2

7.3

70

13.7

120

1.2

2.5

1.95

2.5

6.6

7.8

90

8.21

100

1.0

4.0

2.5

2.5

7.1

8.4

110

5.09

90

0.9

6.0

3.0

2.5

7.6

8.9

130

3.39

80

0.8

10

3.9

2.5

8.4

9.9

190

1.95

65

0.65

16

5.0

2.5

9.5

11.1

250

1.24

50

0.55

25

6.4

2.5

10.8

12.7

330

0.795

45

0.45

35

7.7

2.5

12.0

14.1

430

0.565

40

0.4

50

9.2

2.5

13.4

15.7

570

0.393

35

0.35

70

11.0

2.5

15.1

17.7

760

0.277

30

0.3

95

12.5

2.7

16.9

19.8

980

0.210

30

0.3

120

14.2

2.7

18.5

21.7

1210

0.164

25

0.25

150

15.8

2.7

20.0

23.4

1500

0.132

20

0.2

185

17.5

2.7

21.6

25.3

1800

0.108

20

0.2

240

20.1

2.7

24.1

28.2

2360

0.0817

20

0.2

300

22.5

2.7

26.3

30.8

2840

0.0654

15

0.15

400

25.8

2.9

29.8

34.9

3800

0.0495

15

0.15

(a) = ½ö¹©²Î¿¼

 


¹«Ë¾¼ò½é
²úƷĿ¼
¹©Ó¦ÐÅÏ¢

¹«Ë¾Ãû³Æ£º ¿­À³¶«ÄáµçÏßµçÀÂÉϺ£°ìÊ´¦
µç »°£º 86 18930597072 / °×Ůʿ
ÊÖ»ú£º 18930597072
µØ Ö·£º ÄϾ©Î÷·ÖÐÐÅÌ©¸»¹ã³¡
ÓÊ ±à£º 250041
Ö÷ Ò³£º www.caledoniancable.com

¸Ã³§ÉÌÏà¹Ø²úÆ·£º
  • MD4·À»ðͨѶµçÀÂ(CR1-C1 Class)
  •  
  • 209Y to BS 6500
  •  
  • GKWÌú·ӦÓÃÇ£ÒýµçÀÂ
  •  
  • EN 50264 ±ê×¼±ÚµçÁ¦¼°¿ØÖƵçÀÂ
  •  
  • EN 50382 ¸ßεçÀÂ
  •  
  • EN 50306 ±¡±ÚÒÇ±í¼°¿ØÖƵçÀÂ
  •  
  • EN 50382 ¸ßεçÀÂ
  •  
  • EN 50264 ±ê×¼±ÚµçÁ¦¼°¿ØÖƵçÀÂ
  •  
  • K27·À»ð¿ØÖƵçÀÂ(CR1-C1 Class)
  •  
  • EN 50306 ±¡±ÚÒÇ±í¼°¿ØÖƵçÀÂ
  •  
    ¸ü¶à²úÆ·...
      ¹ØÓÚÎÒÃÇ | ÁªÏµÎÒÃÇ | ¹ã¸æ·þÎñ | ±¾Õ¾¶¯Ì¬ | ÓÑÇéÁ´½Ó | ·¨ÂÉÉùÃ÷ | ·Ç·¨ºÍ²»Á¼ÐÅÏ¢¾Ù±¨  
    ¹¤¿ØÍø¿Í·þÈÈÏߣº0755-86369299
    °æȨËùÓÐ ¹¤¿ØÍø Copyright@ Gkong.com, All Rights Reserved