Caledonian µçÀÂÓÐÏÞ¹«Ë¾ÓµÓÐÒ»Ì×ÍêÕûµÄÉú²ú¸÷ÖÖÍÀº͸÷ÖÖ¹âÏ˵ÄÏȽøÉ豸£¬¿ÉÒÔÉú²ú³öÊýÒÔ°Ù¼ÆÖÖÀàµÄ²¼Ïßϵͳ²úÆ·¡£ÎÒÃǵĸ÷ÖÖÍÀº͸÷ÖÖ¹âÏ˵IJúÆ·ÐÔÄÜ׿Խ£¬ÓÅÖʵķþÎñÖÊÁ¿£¬²»½öΪ¹ã´óÓû§ÌṩÁ˸ÃÁìÓòÄڵĸ߶˲úÆ·£¬»¹½«¸÷ÖÖÏßÀµÄÓ¦Ó÷¢»Óµ½Á˼«Ö¡£
ÔÚ¸÷ÖÖ¹ú¼Ê±ê×¼·½Ã棬 Caledonian µçÀ²úÆ·¸ù¾Ý¿Í»§ÐèÒª£¬¿É·ûºÏÓ¢¹ú±ê×¼BS£¨BS2863/4006/5308/5467/5468/6004/6007/6141/6300/6346/6360/6387/ 6425/6500/6724/6746/6853/6899/7211/µÈ £©¡¢Å·ÖÞ±ê×¼EN£¨EN50173/50264/50265/50266/50288/50306/50382/ 10257-1:1998/ 10257-2:1998/ 186003:1994/ 186160:1997/ 1862:1998µÈ£©¡¢·¨¹ú±ê×¼NF£¨NF CR1 C1/F 16-101/F 63-826/F 63-808/F 63-827/ C32-321/ C32-322/ C32-070µÈ£©¡¢µÂ¹ú±ê×¼DIN/VDE£¨DIN5510/51900|/VDE0281/0282/0295/0245/0812/0814/0276µÈ£©¡¢Òâ´óÀû±ê×¼UNI(H03VV-F/H03VVH2-F/H05VV-F/H05VVH2-F/H05RN-F/H05RNH2-F/H05RR-F/H07RN8-F/H03RT-H/A07RN-F/FR2OH2R/FG7OHH2R)ÃÀ¹ú±ê×¼RS/ANSI£¨RS 485/422/232/423/568|ANSI/UL83/1063/44/1581£©¡¢ÆÏÌÑÑÀ±ê×¼£¨NP£©¡¢Î÷°àÑÀ±ê×¼UNE£¨UNE211002/21123/211025/21150£©¡¢¹ú¼Êµç¹¤Î¯Ô±»á±ê×¼IEC£¨IEC11801/60502-1/60502-2/60332-1/60332-3/60331/60754-1/61034/61156/60228µÈ£©¡¢¹ú¼Ê±ê×¼ISO£¨ISO 9001/14000/4589-3£©µÈµÈ¡£
Õ⼸ʮÄêÀ´£¬ Caledonian µçÀÂÓÐÏÞ¹«Ë¾Ò»Ö±¶¼ÔÚÎȶ¨µØÔö¼Ó×ÔÉíµÄ»õÎï´¢±¸²¢²»¶ÏµØÍØÕ¹ÓëÈ«ÇòµÄ¿Í»§ºÍºÏ×÷»ï°éÖ®¼äµÄóÒ×¹ØÏµ£¬²¢ÇÒÒѾÔÚÅ·ÖÞºÍÑÇÖÞ¿ª±ÙÁËÊг¡·Ý¶î¡£
Caledonian»¹ÔÚÑÇÖÞÉèÁ¢Á˰ìÊ´¦£¬°üÀ¨¶«ÄÏÑǵÄÐÂ¼ÓÆÂ£¬ÖйúµÄÉϺ£ºÍÏã¸Û£¬ÈÕ±¾µÄ¶«¾©µÈµØ¡£²úÆ·µÄ·ÖÅäÓɽüÆÚÔÚÖйúºÍÐÂ¼ÓÆÂÉèÁ¢µÄ°ìÊ´¦Ìṩ֧³Ö¡£
¶ÔÓÚº£ÍâÏîÄ¿CaledonianÓÈÆäÓиüºÃµÄÓÅÊÆ£¬¶ÔÓÚº£ÍâÏîÄ¿¿Í»§ÎÒÃÇ¿ÉÌṩ£ºÕë¶Ô¸ÃÏîÄ¿µÄרҵ²ÊÒ³£»º£ÍâÏîÄ¿±¨Éó×ÊÁÏ£»²úÆ·ÑùÆ·£»¿ÉÌṩµÚÈý·½¼ì²â±¨¸æ£»¿É²ÉÓú£ÔË¡¢¿ÕÔ˵ȶàÖÖ·½Ê½ÔËÊ䣻¿ÉÓ뺣Íâ¼àÀí¡¢ÒµÖ÷½øÐÐÃæ¶ÔÃæ¹µÍ¨ºÍ²úÆ·ÑÝʾ¡£
CaledonianÒѾ¸úÐí¶à¹ú¼ÒÏîÄ¿³É¹¦ºÏ×÷£¬°üÀ¨»ú³¡ÅܵÀϵͳ¡¢»ú³¡ÐÐÀîϵͳ¡¢µç³§¿ØÖÆÏµÍ³¡¢¸ßËÙ¹«Â·¿ØÖÆÏµÍ³¡¢¸ßËÙ¹«Â·ÊÕ·Ñϵͳ¡¢¸ßËÙÌú·»ú³µ¡¢µØÌúµçÀÂϵͳ¡¢ÈûÀÃÅ¡¢ÆÁ±ÎÃÅ¡¢¿Õµ÷¡¢PIS¡¢CCTVϵͳµÈ£¬ÔÚ¸÷¹úÁôÏÂ¸ßÆ·ÖʵÄÏîÄ¿ÖÊÁ¿ºÍÆ·ÅÆ¿Ú±®¡£
CaledonianÆÚ´ýÓëÄúµÄÕæ³ÏºÏ×÷¡£
FIREROL FRL-SW-05M/FRL-SW-1M

A. µ¼Ìå B. ¾øÔµ C. »¤Ì×
Ó¦ÓÃ
ÔÚÌú·ÔËÊä»ú³µµÄÄÚ²¿»òÍⲿ°²×°Ê±ÓÃ×÷µçÁ¦ºÍ¿ØÖƵçÀ£¬ÔÚÕâÖÖ»·¾³Ï°áÔ˺Ͱ²×°³É±¾ÊÇÐèÒª¿¼ÂǵĺÜÖØÒªÒòËØ¡£
ÓÃÓÚ¿ØÖÆ£¬¸¨ÖúºÍÖ÷µç·½ÓÏßÈçÓÐÏßµçÊÓµõ´ø£¬¿ª¹ØºÍ¿ØÖÆÃæ°å£¬¼Ýʻ̨µÈ¡£
µçÀ½ṹ
µ¼Ìå
·ûºÏHD383 (IEC 60228) class 5 ±ê×¼µÄÈáÈí¶ÆÎýÍË»ðÍË¿
¾øÔµ
·ûºÏEN 50264-1 (EM 101 ÖÁ EM 105) ±ê×¼µÄµÍÑÌÎÞ±(LSZH) µ¯ÐÔ»¯ºÏÎï
Í⻤Ì×
·ûºÏEN 50264-1 (EM 101 ÖÁ EM 104) ±ê×¼µÄµÍÑÌÎÞ±(LSZH) µ¯ÐÔ»¯ºÏÎï
µçÆø¼°»úеÐÔÄÜ
µçѹ |
300/500 V »ò 0.6/1 kV |
µ¼Ìå×î¸ß¶î¶¨ÎÂ¶È |
90¡æ ( ¹Ì¶¨°²×°) |
ÔÊÐí×îµÍ»·¾³ÎÂ¶È |
-25¡æ /-40¡æ ( ¹Ì¶¨°²×°) |
×îСÍäÇú°ë¾¶ |
3 ±¶×î´óÍâ¾¶ (D<12mm) |
4 ±¶×î´óÍâ¾¶ (D>12mm) |
»¯Ñ§¼°»·¾³ÌØÐÔ
EN 60684-2 |
ÎÞ·ú |
EN 50305; EN 60811-2-1 |
ÄÍÓͼ°·ÀȼÁÏ |
EN 50305 |
·À³ôÑõ |
³µÔØÏµÍ³Ó¦ÓõķÀ»ðÐÔÄÜ
EN 50306-2 |
ΣÏյȼ¶ HL1, HL2/HL3, HL4 |
DIN 5510-2 |
°²È«µÈ¼¶ 1/2/3/4 |
BS 6853 |
ÊÒÄÚÓ¦ÓÃ 1a, 1b, II; ÊÒÍâÓ¦ÓÃ 1a, 1b, II |
NF F 16-101 |
FO |
»ù±¾·À»ðÐÔÄÜ
EN 50265-2-1; IEC 60332-1; BS 4066-1 |
µ¥¸ù¾øÔµµçÏß( µçÀÂ) ´¹Ö±»ðÑæ´«²¥²âÊÔ |
EN 50266-2-4 + EN 50305; IEC 60332-3C; |
³ÉÊøµçÏß( µçÀÂ) »ðÑæ´«²¥²âÊÔ |
VDE 0472 Teil 804; BS 4066-3; NFC 32070 |
|
EN 50268-2; IEC 61034-2; VDE 0472 Teil 816 |
ÑÌÃܶȲâÊÔ |
EN 50267-2-1; IEC 60754-1; VDE 0472 Teil 815 |
ÎÞ±²âÊÔ |
EN 50267-2-2/3; IEC 60754-2; VDE 0472 Teil 813 |
ÆøÌ帯ʴÐÔ²âÊÔ ( Ëá¶È & ´«µ¼ÐÔ) |
EN 50305; NFX 70-100; NFF 63808; TM1-04; BS6853 |
¶¾ÐÔÖ¸Êý²âÊÔ |
NFF 16101; NFF 63808; BS6853 |
ÑÌÖ¸Êý²âÊÔ |
FRL-SW-05M 300/500 V
оÊýxµ¼Ìå
½ØÃæ»ý (a)
|
µ¼ÌåÖ±¾¶(b)
|
×îСƽ¾ù¾øÔµºñ¶È
|
ÏßоÍâ¾¶
|
×îСƽ¾ù
»¤Ì׺ñ¶È
|
ÏßÀÂÍâ¾¶
|
ÖØÁ¿
|
×î´óµ¼Ìå×迹
|
×îС¾øÔµ×迹
|
20°C
|
EI 105
|
EI 101- EI 104 |
×îС
|
×î´ó
|
×îС
|
×î´ó
|
20°C
|
20°C
|
n x mm2
|
mm
|
mm
|
mm
|
mm
|
mm
|
mm
|
mm
|
kg/km
|
Ω/km
|
MΩ·km
|
MΩ·km
|
2x1
|
1.2
|
0.6
|
2.4
|
2.8
|
1.4
|
7.2
|
8.5
|
100
|
20.0
|
140
|
70
|
4x1
|
1.25
|
0.6
|
2.4
|
2.8
|
1.4
|
8.2
|
9.6
|
130
|
20.0
|
140
|
70
|
7x1
|
0.6
|
2.4
|
2.8
|
1.4
|
9.6
|
11.2
|
180
|
20.0
|
140
|
70
|
9x1
|
0.6
|
2.4
|
2.8
|
1.4
|
11.5
|
13.4
|
220
|
20.0
|
140
|
70
|
12x1
|
0.6
|
2.4
|
2.8
|
1.4
|
12.3
|
14.4
|
280
|
20.0
|
140
|
70
|
19x1
|
0.6
|
2.4
|
2.8
|
1.4
|
14.5
|
16.6
|
400
|
20.0
|
140
|
70
|
24x1
|
0.6
|
2.4
|
2.8
|
1.5
|
16.7
|
19.6
|
530
|
20.0
|
140
|
70
|
32x1
|
0.6
|
2.4
|
2.8
|
1.6
|
18.5
|
21.7
|
660
|
20.0
|
140
|
70
|
37x1
|
0.6
|
2.4
|
2.8
|
1.6
|
19.2
|
22.4
|
720
|
20.0
|
140
|
70
|
40x1
|
0.6
|
2.4
|
2.8
|
1.6
|
19.9
|
23.3
|
750
|
20.0
|
140
|
70
|
4x1.5
|
1.5
|
0.7
|
2.8
|
3.3
|
1.4
|
9.2
|
10.8
|
170
|
13.7
|
120
|
60
|
7x1.5
|
0.7
|
2.8
|
3.3
|
1.4
|
10.9
|
12.8
|
250
|
13.7
|
120
|
60
|
9x1.5
|
0.7
|
2.8
|
3.3
|
1.4
|
13.1
|
15.3
|
310
|
13.7
|
120
|
60
|
12x1.5
|
0.7
|
2.8
|
3.3
|
1.4
|
14.0
|
16.4
|
400
|
13.7
|
120
|
60
|
19x1.5
|
0.7
|
2.8
|
3.3
|
1.5
|
16.5
|
19.4
|
570
|
13.7
|
120
|
60
|
24x1.5
|
0.7
|
2.8
|
3.3
|
1.6
|
19.5
|
22.8
|
760
|
13.7
|
120
|
60
|
32x1.5
|
0.7
|
2.8
|
3.3
|
1.7
|
21.5
|
25.2
|
940
|
13.7
|
120
|
60
|
37x1.5
|
0.7
|
2.8
|
3.3
|
1.7
|
22.4
|
26.2
|
1040
|
13.7
|
120
|
60
|
4x2.5
|
1.95
|
0.8
|
3.4
|
4.0
|
1.4
|
10.7
|
12.5
|
240
|
8.21
|
90
|
45
|
7x2.5
|
0.8
|
3.4
|
4.0
|
1.4
|
12.7
|
14.9
|
360
|
8.21
|
90
|
45
|
9x2.5
|
0.8
|
3.4
|
4.0
|
1.5
|
15.6
|
18.3
|
450
|
8.21
|
90
|
45
|
12x2.5
|
0.8
|
3.4
|
4.0
|
1.5
|
16.7
|
19.6
|
590
|
8.21
|
90
|
45
|
19x2.5
|
0.8
|
3.4
|
4.0
|
1.6
|
19.7
|
23.1
|
860
|
8.21
|
90
|
45
|
24x2.5
|
0.8
|
3.4
|
4.0
|
1.8
|
23.5
|
27.5
|
1150
|
8.21
|
90
|
45
|
(a) = ¿É°´¿Í»§ÒªÇóÌṩ»ÆÂÌÉ«½ÓµØÏß
(b) = ½ö¹©²Î¿¼
FRL-SW-1M 0.6/1 kV
µ¼Ìå½ØÃæ»ý (a)
|
µ¼ÌåÖ±¾¶(a)
|
×îСƽ¾ù¾øÔµºñ¶È
|
ÏßоÍâ¾¶ (a)
|
×îСƽ¾ù
»¤Ì׺ñ¶È
|
ÏßÀÂÍâ¾¶
|
ÖØÁ¿
|
×î´óµ¼Ìå×迹
|
×îС¾øÔµ×迹
|
20°C
|
EI 105
|
EI 101- EI 104 |
×îС
|
×î´ó
|
×îС
|
×î´ó
|
20°C
|
20°C
|
mm2
|
mm
|
mm
|
mm
|
mm
|
mm
|
mm
|
mm
|
kg/km
|
Ω/km
|
MΩ·km
|
MΩ·km
|
Á½Ð¾
|
1.5
|
1.5
|
0.8
|
3.0
|
3.5
|
1.4
|
8.5
|
9.9
|
140
|
13.7
|
150
|
75
|
2.5
|
1.95
|
0.8
|
3.4
|
3.9
|
1.4
|
9.3
|
10.9
|
180
|
8.21
|
130
|
65
|
4
|
2.5
|
0.8
|
3.9
|
4.6
|
1.4
|
10.3
|
12.1
|
230
|
5.09
|
110
|
55
|
6
|
3.0
|
0.9
|
4.6
|
5.4
|
1.4
|
11.8
|
13.9
|
300
|
3.39
|
90
|
45
|
10
|
3.9
|
1.1
|
5.8
|
6.8
|
1.4
|
14.3
|
16.7
|
480
|
1.95
|
85
|
45
|
16
|
5.0
|
1.1
|
7.2
|
8.5
|
1.5
|
16.5
|
19.4
|
630
|
1.24
|
70
|
35
|
25
|
6.4
|
1.3
|
8.6
|
10.0
|
1.6
|
20.1
|
23.5
|
920
|
0.795
|
65
|
35
|
35
|
7.7
|
1.3
|
10.2
|
11.5
|
1.7
|
22.7
|
26.6
|
1200
|
0.565
|
60
|
30
|
50
|
9.2
|
1.5
|
11.6
|
13.5
|
1.9
|
26.7
|
31.2
|
1670
|
0.393
|
55
|
30
|
Èýо
|
1.5
|
1.5
|
0.8
|
3.0
|
3.5
|
1.4
|
8.9
|
10.5
|
160
|
13.7
|
150
|
75
|
2.5
|
1.95
|
0.8
|
3.4
|
3.9
|
1.4
|
9.9
|
11.6
|
210
|
8.21
|
130
|
65
|
4
|
2.5
|
0.8
|
3.9
|
4.6
|
1.4
|
11.0
|
12.9
|
270
|
5.09
|
110
|
55
|
6
|
3.0
|
0.9
|
4.6
|
5.4
|
1.4
|
12.5
|
14.6
|
360
|
3.39
|
90
|
45
|
10
|
3.9
|
1.1
|
5.8
|
6.8
|
1.5
|
15.3
|
17.9
|
600
|
1.95
|
85
|
45
|
16
|
5.0
|
1.1
|
7.2
|
8.5
|
1.6
|
17.8
|
20.8
|
790
|
1.24
|
70
|
35
|
25
|
6.4
|
1.3
|
8.6
|
10.0
|
1.7
|
21.6
|
25.3
|
1170
|
0.795
|
65
|
35
|
35
|
7.7
|
1.3
|
10.2
|
11.5
|
1.8
|
24.4
|
28.6
|
1530
|
0.565
|
60
|
30
|
50
|
9.2
|
1.5
|
11.6
|
13.5
|
1.9
|
28.2
|
33.3
|
2120
|
0.393
|
55
|
30
|
ËÄо
|
1.5
|
1.5
|
0.8
|
3.0
|
3.5
|
1.4
|
9.7
|
11.3
|
190
|
13.7
|
150
|
75
|
2.5
|
1.95
|
0.8
|
3.4
|
3.9
|
1.4
|
10.7
|
12.5
|
250
|
8.21
|
130
|
65
|
4
|
2.5
|
0.8
|
3.9
|
4.6
|
1.4
|
11.9
|
14.0
|
330
|
5.09
|
110
|
55
|
6
|
3.0
|
0.9
|
4.6
|
5.4
|
1.4
|
13.7
|
16.1
|
450
|
3.39
|
90
|
45
|
10
|
3.9
|
1.1
|
5.8
|
6.8
|
1.5
|
16.9
|
19.8
|
740
|
1.95
|
85
|
45
|
16
|
5.0
|
1.1
|
7.2
|
8.5
|
1.6
|
19.6
|
22.9
|
980
|
1.24
|
70
|
35
|
25
|
6.4
|
1.3
|
8.6
|
10.0
|
1.8
|
24.1
|
28.2
|
1460
|
0.795
|
65
|
35
|
3X35+25
|
7.7/6.4
|
1.3/1.3
|
10.2
/8.6
|
11.5
/10.0
|
1.9
|
28.5
|
34.2
|
1610
|
0.565/0.795
|
60
|
30
|
3X50+25
|
9.2/6.4
|
1.5/1.3
|
11.6 /8.6
|
13.5
/10.0
|
2.0
|
33.4
|
40.0
|
2230
|
0.393/0.795
|
55
|
30
|
(a) = ½ö¹©²Î¿¼